Operation requirements 

The operator has to make sure that laser radiation – also reflected laser radiation – higher than the 

maximum permissible level is avoided by technical or organisational measures 

Make sure to use the correct voltage. Always use a grounded mains connection. Don’t use a remote 

controlled or other electronically switched main connection. Don’t use together with large 

appliances (especially fog machines/hazers) on the same mains. 

If the device is used in a flying installation, the mounting brackets and an appropriate safety-rope 

must be fixed. 

In some countries the operator must notify the accidence insurance and the authority for industrial 

safety before operating a laser. For more information contact the relevant authorities. 

Please consider that unauthorized modifications on the device are strictly forbidden due to safety 

reasons! 

If this device will be operated in any way differently than described in this manual, the product may 

suffer damages and the guarantee becomes void. Furthermore, any other operation may lead to 
dangers like short-circuit, burns, electric shock, etc. 

Keep surrounding dry and clean. T

his unit should be keep dry, do not use in the rain or damp and 

dusty environment, don’t place liquid filled receptacles on the device. Projector should be put in a 

water-proof housing when operated outside.  

Regularly open the device (see “cleaning” further down) to check for dust inside, or if fog fluid 

condenses in the housing (if so rearrange hazer and/or laser position). 

Operating temperature is 10~35

°C

. In a new installation, check after some 15-30 minutes whether 

the outlet air gets too warm. Regularly check the inside for dust deposits, especially around the 

fans. Let laser cool off 10 minutes after 2 hours of operation, to ensure maximum lifetime for the 

diode. Be careful not to direct stage lights toward the laser (especially moving heads), this can 

cause overheating. 

Distance between laser aperture and projection screen should be not less than 1 meter. 

Do not turn device on and immediately off again frequently. 
Do not look into the laser beam directly, especially not with optical instruments. 

Do not touch the device with wet hands. 

When the laser diode becomes dim or broken, please contact your dealer timely. 

When returning laser to dealer/manufacturer always use original packaging.

 

Maintenance should be performed every 15-day period. See “cleaning” further down.

 

Operation 

Caution – use of controls or adjustments or performance of procedures other 

than those specified herein may result in hazardous radiation exposure. 

Connect the power cable to the mains. The red LED on the front panel should turn on and the laser 

beam will exit through the front opening – be careful. Now the device is in automatic mode.  

Sound-/automatic mode 

In automatic mode the patterns will be displayed automatically in a round robin fashion. Operating 

switch 1 will set the device to sound mode. In sound mode the patterns are changed and animated 

to the beat of the music. You can control the music-sensitivity of the microphone with the min-max 

knob at the back panel. The Mic LED flashes when the audio is triggered. 

DMX control 

Setting Switch 10 to „off“ puts the device into DMX mode. Connect a DMX controller to operate the 

laser. The red LED on the back panel will flash as long as a DMX signal is detected. 
To set the DMX address of the laser use switches 1 to 9, each switch represents a number 

Switch 

number 

switch 

number 

32 

64 

128 

Содержание EL-700 GB

Страница 1: ...ty instructions 3 Operation requirements 4 Operation 4 Sound automatic mode 4 DMX control 4 Maintenance cleaning 5 Troubleshooting 6 Technical specifications 6 Please note 6 Lieferumfang 7 Hinweise zu...

Страница 2: ...erlischt sofort jeder Anspruch auf Gew hrleistung Wenn das Ger t gro en Temperaturschwankungen ausgesetzt war nicht sofort anschalten Gefahr der Kondenswasserbildung Benutzen Sie immer eine Steckdose...

Страница 3: ...ZARD Never look directly into the light source as sensitive persons may suffer an epileptic shock These lasers are considered a definite eye hazard particularly at the higher power levels which WILL c...

Страница 4: ...s whether the outlet air gets too warm Regularly check the inside for dust deposits especially around the fans Let laser cool off 10 minutes after 2 hours of operation to ensure maximum lifetime for t...

Страница 5: ...d 5 Point speed 6 horizontal movement 7 vertical movement 8 Colour 1 101 green and red 102 199 red 200 255 green 9 Reset above 200 shortly Please note that not all effect channels work with every patt...

Страница 6: ...m green 220mW 655nm red o EL 700GB max 700mW 80mW 532nm green 450mW 445nm blue Beam EL 400RG ca 3mm 1mrad EL 700GB ca 3mm 2mrad Laser class 3b 4 Scanning system fast stepper motors ca 2 5 kpps Weight...

Страница 7: ...cht verdeckt sein 9 Netzstecker Kaltger tebuchse zug nglich halten Warnhinweise 1 Betreiben Sie das Ger t nur gem ss dieser Betriebsanleitung 2 Die L ftungs ffnungen m ssen beim Betrieb des Geh uses f...

Страница 8: ...ewechselt werden Hierbei werden die Muster soundgesteuert gewechselt Um die Empfindlichkeit der Musiksteuerung einzustellen benutzen sie den Einstellknopf an der R ckseite des Lasers Die Mic LED blink...

Страница 9: ...en Sie bitte die obere Reihe Schrauben an der Vorder und R ckseite Der Deckel l sst sich nun abnehmen Entfernen Sie eventuelle Staubansammlungen insbesondere im Bereich der L fter und Laser Sollten si...

Страница 10: ...einwandfrei Der Benutzer des Ger ts muss die lokalen Sicherheitsbestimmungen und die Warnhinweise in der Betriebsanleitung beachten Sch den die durch unsachgem sse Handhabung entstehen unterliegen nic...

Отзывы: