56
The LED circled in blue is the reset light. This light should only turn on when the
reset button is hit. If it stays “on” all the time then the mainboard needs to be
changed.
The LED circled in yellow is the initialization light. This light turns on when the
machine is turned on. It will turn off after the initialization process. If it stays on,
then mainboard is damaged.
The LEDs circled in purple are the door sensor lights.
When all doors are closed, all three LEDs will stay “on”.
When the front door is open or front door sensors malfunctioning, all the LED
will turn off.
When the backdoor is open or the backdoor sensors are malfunctioning, the two
leftmost LEDs will turn “on”.
When the top cover is open or the top cover sensors are malfunctioning, the left
most LED turns to “on”.
The LEDs circled in red are the laser tube status lights.
For 50W & 100W models:
Under normal condition, the fourth light counting from the left will be “ON.”
However, the brightness of the LED depends on the power level used.
Distributed & Supported by: Jorlink USA, Inc. | Tel: (336) 288-1613 | [email protected] | www.JORLINK.com
57/60