ICS-KP14 Instruction Manual
01850-53-000
Page 17 of 18
Issue 3 19 January 2021
Fit a shorting link or otherwise apply a connection across the two-pin header J3, refer to the diagram
in the Wiring section.
Switch on the power to the keypad for five seconds, then switch off. Note that for newer ICS control
panels such as the ICS-6, the system will need to be armed to turn on the keypad power.
Remove the connection across J3.
Refit the keypad to the wall, see ‘Attaching the Keypad to the Backplate’.
Switch on the power to the keypad. The Program Code is now reset to the factory default value of
1234.
10
Specifications
Safety Performance
Up to PL’e’ to EN ISO 13849-1:2008
Operating Voltage
24VDC
Current Consumption
25mA standby
150mA activated
Size
160mm wide X 108mm high X 38.5mm deep
Weight
200g
All figures quoted are approximate. Lasermet reserve the right to alter specifications without prior
notice.
11
Warranty
Lasermet provide a 12-month warranty for defects in materials and manufacture, from the date of
installation or delivery. Installations completed by Lasermet are covered against defects in
workmanship for 12 months.
Damage or defects caused by other factors are not covered. For example, industrial contamination,
incorrect cleaning, storm damage. Consequential loss is not covered under warranty. Compensation
for indirect or direct loss or damage is expressly excluded. Rectification of the defects or a replacement
does not initiate a new warranty period.
For all deliveries, payments and other legal transactions, English law takes precedence for any
litigation.