background image

4

QUAD 4000

NOTE:

 

Automatic Shutoff Feature:

 If after initial 

setup, the Quad 4000 is bumped or moved, the 
system shuts down to avoid line, square, plumb or 
level errors from occurring. 

!

12

13

15

16

17

18

14

2

6

8

7

11

9

10

3

4

5

1

4

3

5

18

19

1.  Power Button:

  System defaults to vertical 

and will start “seeking” the LineLokr (LL) 

automatically. If LineLokr is not turned on, 

the display reads  

“No Signal”

2.  Mode Button:

  You can select “Horizontal 

Mode” or “Vertical and Horizontal Mode” 

by toggling the button

3.  Mode Status: 

  Indicates what mode you 

are in 1 Vertical Mode, 2 Horizontal Mode, 3 

Vertical & Horizontal

4.  Battery Status:

  Indicates approximate 

battery life

5.  Self-Leveling Status:

  Indicates if unit is in 

process of leveling, or if it is level

6.  Manual Line Mode Button:

  The Quad 4000 

can manually be adjusted for line if LineLokr 

is not used

7.  Manual Line Left:

  With the Quad in 

“Manual Line Mode”, depressing this 

button drives laser to the left

8.  Manual Line Right:

  With the Quad in 

“Manual Line Mode”, depressing this 

button drives laser to the right

9.  Laser Plumb Bob: 

 Used to set Quad over a 

point when in vertical & horizontal mode or 

vertical only mode. Plumb- bob laser shuts off 

after 3 minutes to save battery power

10. 5/8x11 Mount:

  On bottom side of Quad for 

tripod mounting

11. Battery Door Knob:

  Turn ¼ turn to left 

to open door (Takes 4ea. D cell Alkaline 

batteries)

12. Horizontal (Level) Exit Window:

  Provides 

360° level control for your jobsite

13. Vertical Laser Exit Windows:

  Provides line, 

square and plumb control for your jobsite

14. Bulls Eye Bubble:

  For leveling to bring the 

Quad within its self-leveling range

15. Sighting Device:

  For aiming the Quad to the 

LineLokr

16. Communication Antenna: 

 Receives signal 

from the LineLokr to drive laser left or right 

for centerline

17. Molded Carrying Handle:

  Allows easy and 

sure handling of the Quad 4000

18. LCD Display:

  Displays function status of the 

Quad 4000

19. Radio Signal Strength:

  Displays signal 

strength between Quad and LinLokr

QUAD 4000 CONTROLS & FEATURES

Vertical laser exit 

windows on the 

front, rear, left  

and right

Содержание QUAD 4000

Страница 1: ...QUAD 4000 LINE SQUARE LEVEL PLUMB ALL IN ONE ALL AT ONCE U S Patent No 7266897 Patent Pending Designed and built in Redmond Oregon ONE MAN LAYOUT AND CONTROL OWNERS MANUAL...

Страница 2: ......

Страница 3: ...up the Quad 4000 and LineLokr 6 7 Agular Accuracy and how setup can affect it 8 Setup considerations when using the LineLokr 9 Let s get started How to set it up 10 11 Checking for square calibration...

Страница 4: ...cates with the Quad 4000 laser automatically driving the laser to centerline and holding it there all day long Line square and plumb will not drift off because it is always being monitored and correct...

Страница 5: ...ime ALL IN ONE ALL AT ONCE Square your job control elevation snap your lines and plumb the structure with just one man at one time with one laser from one setup It s easy to use and accurate LINE LOCK...

Страница 6: ...left 8 Manual Line Right With the Quad in Manual Line Mode depressing this button drives laser to the right 9 Laser Plumb Bob Used to set Quad over a point when in vertical horizontal mode or vertica...

Страница 7: ...lay the LineLokr will continue to lock to the highest possible accuracy LineLokr accuracy is not affected by deadband setting 5 LCD Display Indicates whether Quad 4000 is driving left driving right or...

Страница 8: ...uad 4000 and LineLokr are communicating Seeking Left Laser is driving to the left looking for the LineLokr Seeking Right Laser is driving to the right looking for LineLokr Locking Line Quad 4000 has f...

Страница 9: ...ked to line then the 90 beams are reactivated and you re ready to go back to squaring or plumbing This function does not work if the unit is in the manual line mode QUAD 4000 KNOCKED DISTURBED AUTO SH...

Страница 10: ...your point ANGULAR SQUARE ACCURACY ON THE JOBSITE IS PRIMARILY AFFECTED BY TWO THINGS FOR LINE SQUARING AND PLUMB GET TO THE POINT GET DIRECTLY OVER YOUR POINT OR YOU WILL BE OFF LINELOKR ON POINT QU...

Страница 11: ...TUAL RANGE CAN VARY DEPENDING ON CONDITIONS SUCH AS HEIGHT OFF THE GROUND HIGHER IS BETTER SPARKING OR WELDING OPERATION NEARBY IN SOME CASES THE TYPE OF OUTDOOR LIGHTING HIGH WINDS BUFFETING THE LASE...

Страница 12: ...enna is in the upright position When powered up the Quad will automatically default to the VERTICAL mode for the line square and plumb applications 4 Level the bullseye bubble on the Quad by extending...

Страница 13: ...E C LEVELING ONLY FOR ALL LEVELLING TASKS B 1 Set up Quad 4000 on the tripod and level Quad bulls eye bubble by extending or contracting the tripod legs 2 Power up Quad 3 Using Mode button toggle unti...

Страница 14: ...00 200 QUAD From C mid point go out 200 feet to left and mark your 90 at point D using a laser detector 3 A C D B QUAD LINELOKR Check here Check here Using a laser detector go to A and B and measure w...

Страница 15: ...laser at and mark this spot 6 Rotate the Quad 4000 180 7 Find ON GRADE on the wall at the same location as your first mark 8 The two marks should be within 1 16 of each other at 100 feet from the las...

Страница 16: ...or FCC DECLARATION This device complies with Part 15 of the FCC rules Operation is subject to the following two conditions 1 this device may not cause any harmful interference and 2 this device must a...

Отзывы: