3-4. If the machine is not started, repeat step 3. When the mahcine is started, open the solution valve to start
spraying (water cooling type: first open water tank valve and then open the solution tank valve. Both valves cannot
fully open, only 1/3, Max. 1/2.). Note: before the machine is started, both valves must be closed. Before turning
off, both valves must be closed.
3-5 Gas tube starting method:
a. Before the machine is started, press the test power to
check if there is squeak sound of the ignition needle. When the
sou_nd is normal, the machine can be started.
b. To long press the test power with one hand, to pull the gas
tube from slow to fast to inflate by the other hand, the sound of
machine starting can be heard after about pulling 5-6 times.
Don't release the test power before the machine is started.
Then stop pulling, open the solution valve and start to_ spray.
➔
4.
Safely shutdown procedure:
After the work is completed, first close the solution valve, and then switch off gear 1 and 2. After power off, open one
solution box cover to release the excessive gas in the shortest time