EPL-SL-4-50X-50LED-RT-MBC-EPP 

TO AVOID EXPLOSION: 

MAKE SURE THE SUPPLY VOLTAGE IS WITHIN THE VOLTAGE RATING.

ENSURE THE MARKED T RATING IS LESS THAN THE IGNITION TEMPERATURE OF THE HAZARDOUS

ATMOSPHERE.

DO  NOT  OPERATE  IN AMBIENT  TEMPERATURES  ABOVE  THOSE  INDICATED  ON  THE PRODUCT

NAMEPLATE.

DO  NOT  OPERATE  IF THE  LENS, CORD, SEALS, HOUSING, RECEPTACLES, ETC. IS CRACKED  OR

DAMAGED. IF SO, DISCONTINUE USE AND CONTACT MANUFACTURER FOR REPLACEMENT PARTS.

ALL FASTENERS SHOULD BE PROPERLY SEATED.

Magnetic Warning 

PEOPLE WITH PACEMAKERS SHOULD CONSULT THEIR PHYSICIAN(S) BEFORE USE.

ELECTROMAGNETIC FIELDS IN CLOSE PROXIMITY TO HEART PACEMAKER COULD CAUSE

PACEMAKER INTERFERENCE OR PACEMAKER FAILURE.

KEEP FINGERS AWAY FROM MAGNET WHEN MOUNTING AS INJURY COULD OCCUR.

Exp Cord Cap 

Position device near work area for operation. Run cable to  nearby  power 

source. Insert and twist-lock explosion-proof plug into a compatible receptacle 

within the hazardous environment. See 

plug operation

 below. 

PLUG OPERATION 

Electrical connection between plug and compatible receptacle is accomplished 

after plug fully inserts into receptacle and rotated clockwise. 

1.

Lift receptacle door and locate polarization on mating plug pin and

receptacle face. Insert plug straight all the way into receptacle until it

cannot go further.

2.

Rotate plug clockwise limit (37º), this closes internal contacts and

completes circuit. This also mechanically locks plug into receptacle so it

cannot be pulled out.

3.

To remove plug, push plug inward and turn to counterclockwise, pull plug

straight out.

M

OUNTING

 

Each explosion proof LED light features an adjustable swivel bracket constructed of 3/8" aluminum. 

This aluminum mounting bracket has three 200 lb grip magnetic bases which provide a total of 600 lb 

of grip and allows operators to mount the unit to ceilings, walls and any flat metallic surfaces. Users 

simply attach the magnetic mounting bracket to the desired surface, then hang the lamp assembly from 

the bracket.

MAINTENANCE 

Caution: 

To avoid personal injury, disconnect power to the light and allow the unit to cool down before 

performing maintenance. 

Warning: 

No user serviceable parts inside of fixture. Risk of electric shock. Removal of the lens will void 

the warranty. 