Larson Electronics, LLC
Phone: 877-348-9680
Fax: (903) 498-3364
2
of
3
EPL-SL-4-50X-50LED-RT-MBC-EPP
TO AVOID EXPLOSION:
•
MAKE SURE THE SUPPLY VOLTAGE IS WITHIN THE VOLTAGE RATING.
•
ENSURE THE MARKED T RATING IS LESS THAN THE IGNITION TEMPERATURE OF THE HAZARDOUS
ATMOSPHERE.
•
DO NOT OPERATE IN AMBIENT TEMPERATURES ABOVE THOSE INDICATED ON THE PRODUCT
NAMEPLATE.
•
DO NOT OPERATE IF THE LENS, CORD, SEALS, HOUSING, RECEPTACLES, ETC. IS CRACKED OR
DAMAGED. IF SO, DISCONTINUE USE AND CONTACT MANUFACTURER FOR REPLACEMENT PARTS.
•
ALL FASTENERS SHOULD BE PROPERLY SEATED.
Magnetic Warning
•
PEOPLE WITH PACEMAKERS SHOULD CONSULT THEIR PHYSICIAN(S) BEFORE USE.
ELECTROMAGNETIC FIELDS IN CLOSE PROXIMITY TO HEART PACEMAKER COULD CAUSE
PACEMAKER INTERFERENCE OR PACEMAKER FAILURE.
•
KEEP FINGERS AWAY FROM MAGNET WHEN MOUNTING AS INJURY COULD OCCUR.
Exp Cord Cap
Position device near work area for operation. Run cable to nearby power
source. Insert and twist-lock explosion-proof plug into a compatible receptacle
within the hazardous environment. See
plug operation
below.
PLUG OPERATION
Electrical connection between plug and compatible receptacle is accomplished
after plug fully inserts into receptacle and rotated clockwise.
1.
Lift receptacle door and locate polarization on mating plug pin and
receptacle face. Insert plug straight all the way into receptacle until it
cannot go further.
2.
Rotate plug clockwise limit (37º), this closes internal contacts and
completes circuit. This also mechanically locks plug into receptacle so it
cannot be pulled out.
3.
To remove plug, push plug inward and turn to counterclockwise, pull plug
straight out.
M
OUNTING
Each explosion proof LED light features an adjustable swivel bracket constructed of 3/8" aluminum.
This aluminum mounting bracket has three 200 lb grip magnetic bases which provide a total of 600 lb
of grip and allows operators to mount the unit to ceilings, walls and any flat metallic surfaces. Users
simply attach the magnetic mounting bracket to the desired surface, then hang the lamp assembly from
the bracket.
MAINTENANCE
Caution:
To avoid personal injury, disconnect power to the light and allow the unit to cool down before
performing maintenance.
Warning:
No user serviceable parts inside of fixture. Risk of electric shock. Removal of the lens will void
the warranty.