![Larson Davis Spartan 730 Скачать руководство пользователя страница 76](http://html1.mh-extra.com/html/larson-davis/spartan-730/spartan-730_reference-manual_3719581076.webp)
Spartan 730/730IS Dosimeter Manual
A-6
A.1.2 Measurement System Specifications
A.1.3 SLM Specifications
SLM Live View Metrics
Dimensions
206 x 54 x 44 mm
8.11 x 2.13 x 1.73 in
Weight
130 g
4.6 oz
Ingress Protection Rating
IP65
Integration Method
Your choice of the following options.
L
w
eq
: Linear or true RMS
Dose
: computed from Slow time weighting
Integration Time
Min
: 1 second
Max
: 200 days with < 0.5dB error
Time Weightings
Slow, Fast, Impulse, Linear and Peak, simultaneously for selected time
weightings (S,F, or I) indicated by
τ.
Frequency Weightings
A, C, Z parallel and simultaneous for each time weighting, selected
frequency weighting (A, C or Z) indicated by
ω
.
Z-Weight Response
20 Hz to 8 kHz (±2 dB), 10 kHz (±3 dB), >10 kHz to 12.5 kHz (+3/-∞ dB)
Note: Electrical Z-LP attenuates at 10kHz to compensate for microphone
Peak Frequency Weightings
A-, C-, or Z-weighted, parallel, selected peak frequency weighting (A, C, or Z);
indicated by
ρ
Peak Rise Time
≤55 µs
Sample Rate
32k sps
A
C
Z
Units
Linear
L
Aeq(1s)
L
Ceq(1s)
L
Zeq(1s)
dB
Slow
L
AS
L
CS
L
ZS
dB
Fast
L
AF
L
CF
L
ZF
dB
Impulse
L
AI
L
CI
L
ZI
dB
Peak
L
Apeak, 1s
L
Cpeak, 1s
L
Zpeak, 1s
dB