Model 831 Manual
Sound Recording Setup
16-3
Sample Rate Selection
The Sample Rate data field is used to select the sample rate
for the digital data recording. Highlight this field and press
5
to open the Sample Rate Menu shown in Figure 16-2
FIGURE 16-2 Sample Rate Menu
Highlight the desired sample rate and press
5
to make a
selection.
Source Identification Setup
Sample rates above 16k sps are not
available for source identification
recording (see Restrictions below)
The 8k sps setting is generally sufficient for a quality sound
recording that can be used for source identification and
provides the lowest memory consumption. The sound
recording can be recorded automatically by enabling the
Event Recorder (see “Event Sound Recording” on page -14),
Measurement History (see “Measurement History Sound
Recording” on page -18) or manually by enabling Markers
sound recording and then activating a marker (see “Manual
Sound Recording” on page -7).
Advanced Analysis
Be sure to disable the Time History,
Event History and Marker Sound
Record options in order to use the
sound recorder at 24k and 48k sps
(see restrictions below).
To record sound information for advanced analysis, enable
the Measurement History and the Measurement Sound
Recorder settings (see “Measurement History Sound
Recording” on page -18). The sample rate can be 8k, 16k,
24k or 48k sps, with 48k sps offering the highest frequency
bandwidth.
When a measurement is performed by pressing the Run key
(or at a programmed interval), a sound recording file will be
created for the duration specified (unless stopped manually
prior to a complete duration). The resulting sound recording
file can then be downloaded and exported with G4 LD
Utility. The exported wave file can be analyzed with a
software package such as Mat Lab.
Restrictions
It is not possible to use the sound recorder at 24k and 48k at
the same time as the Time History, Event History or Marker
Содержание 831
Страница 1: ...Model 831 Sound Level Meter Manual...
Страница 2: ...I831 01 Rev O Manual Larson Davis Model 831 Manual...
Страница 123: ...5 44 Any Level Display Model 831 Manual...
Страница 135: ...6 12 Run Modes Without Measurement History Model 831 Manual...
Страница 155: ...7 20 Recovery After Improper Shutdown Model 831 Manual...
Страница 209: ...11 22 Markers Model 831 Manual...
Страница 218: ...Model 831 Manual Display of Measurement History Data 12 9 FIGURE 12 7 Measurement History Displays...
Страница 221: ...12 12 Link to Time History Model 831 Manual FIGURE 12 11 Time History Display...
Страница 277: ...15 10 Viewing and Analyzing Results Model 831 Manual FIGURE 15 15 Navigation RIGHT 5 ENTER 5 ENTER...
Страница 321: ...16 24 Sound Recording Playback Model 831 Manual...
Страница 356: ...Model 831 Manual Displays 18 25 FIGURE 18 38 Live Tab Displays FIGURE 18 39 Overall Tab Displays...
Страница 357: ...18 26 Displays Model 831 Manual Session Log Display FIGURE 18 40 Session Log Displays FIGURE 18 41 Current Displays...
Страница 358: ...Model 831 Manual Displays 18 27 FIGURE 18 42 Measurement Displays FIGURE 18 43 Events Displays...
Страница 393: ...20 18 Status Tab Model 831 Manual RS 232 FIGURE 20 21 Status RS 232 USB FIGURE 20 22 Status USB Channel...
Страница 403: ...20 28 Troubleshooting Model 831 Manual...
Страница 413: ...21 10 Calibration When The Model 831 Is Locked Model 831 Manual...
Страница 421: ...23 4 File System Model 831 Manual...
Страница 501: ...A 64 Vibration Sensitivity Model 831 Manual...
Страница 513: ...B 12 Sections 5 6 7 and 9 except 9 3 Model 831 Manual...
Страница 525: ...C 12 Community Noise Descriptors Model 831 Manual...