9: Setup Mode: Advanced Settings
UDS2100 Device Server User Guide
62
Security Settings (Option 6)
You can change security settings by means of Telnet or serial connections only,
not on the Web Manager.
We recommend that you set security over the
dedicated network or over the serial setup to prevent eavesdropping.
Caution:
Disabling both Telnet Setup and Port 77FE will prevent
users from accessing the setup menu from the network. Disabling
Port 77FE also disables the Web from configuring the device.
Select
6
to configure security settings.
Figure 9-2. Security Settings
Disable SNMP (N) ?
SNMP Community Name (public):
Disable Telnet Setup (N) ?
Disable TFTP Firmware Update (N) ?
Disable Port 77FEh (N) ?
77FEh Access Mode (0=Read & Write, 1=Read Only): (0) ?
Disable Web Server (N) ?
Disable Web Setup (N) ?
Disable ECHO ports (Y) ?
Enable Enhanced Password (N) ?
Disable SNMP
This setting allows you to disable the SNMP protocol on the unit for security
reasons. The default setting is
N
(No).
Disable SNMP (N) ? _
SNMP Community Name
The SNMP Community Name is a required field for NMS to read or write to a
device. Enter a string of
1
to
13
characters. The default setting is
public
.
SNMP Community Name (public): _
The default entry is
public
. The current value is displayed in parentheses.
Disable Telnet Setup
Note:
If you choose to disable this option, keep in mind that disabling
both Telnet Setup and Port 77FE will prevent users from accessing the
setup menu from the network.