5: Configuration Using Web Manager
UDS2100 Device Server User Guide
34
Connect Protocol
Protocol
From the drop-down menu, select
TCP.
Connect Mode: Passive Connection
Accept Incoming
Select
Yes
to accept incoming connections. The default
setting is
Yes.
Password Required
Determines whether a password is required for an incoming
passive connection. This field is not available when a
password is set for Telnet mode. The default setting is
No
.
Password
If
Password Required
was set to
Yes
, enter the password
for passive connections.
Modem Escape Sequence
Pass Through
Disable or enable the UDS’s ability to send the escape
sequence. The default is
Yes
(send the escape sequence).
Connect Mode: Active Connection
Active Connect
Select
None
(default)
to disable
Active Connect
. Otherwise,
indicate the connection type from the drop-down list:
With Any Character:
Attempts to connect when any
character is received from the serial port.
With Active Mdm Ctrl In
: Accepts external connection
requests only when the Modem Control In input is asserted.
With Start Character:
Attempts to connect when it receives
a specific start character from the serial port. The default
start character is carriage return.
Manual Connection:
Attempts to connect when directed by
a command string received from the serial port.
Auto Start:
Automatically connects to the remote IP
address and port after booting up.
Start Character
If Active Connect is set to
With Start Character
, enter the
start character in this field. The default setting is
0D
.
Modem Mode
Indicates the on-screen response type when in Modem Mode
(if
Modem Mode
is enabled). The default setting is
None
.
Show IP Address After
RING
Indicates whether to display the remote IP address upon
connection. The default setting is
Yes
.
Endpoint Configuration
Local Port
Enter the local port number.
Auto increment for
active connect
Select to auto-increment the local port number for new
outgoing connections. The range of auto-incremented port
numbers is
50,000
to
59,999
and loops back to the beginning
when the maximum range is reached. Disabled by default.
Remote Port
Enter the remote port number.
Remote Host
Enter the IP address of the remote device.
Common Options
Telnet Com Port Cntrl
This field is available for configuration only when
Active
Connect
is set to
None
. Select
Enable
to permit Telnet