UDS2100 Device Server User Guide
45
8: Setup Mode: Channel Configuration
This chapter explains how to configure the serial ports.
Notes:
Current values display in parenthesis.
You must enter some values in hexadecimal notation. (See F: Binary to
Hexadecimal Conversions.)
Channel 1 (Option 1)
Select
Channel 1
(option
1)
from the Change Setup menu to define how the
serial port responds to network and serial communications. The following
sections describe the configurable parameters within the
Channel
configuration
menu.
Figure 8-1. Serial Port Settings
Baudrate (9600) ?
I/F Mode (4C) ?
Flow (00) ?
Port No (10001) ?
ConnectMode (C0) ?
Send '+++' in Modem Mode (Y) ?
Show IP addr after 'RING' (Y) ?
Auto increment source port (N) ?
Remote IP Address : (000) .(000) .(000) .(000)
Remote Port (0) ?
DisConnMode (00) ?
FlushMode (00) ?
DisConnTime (00:00) ?:
SendChar 1 (00) ?
SendChar 2 (00) ?
Baudrate
The unit and attached serial device, such as a modem, must agree on a speed or
baud rate to use for the serial connection. Valid baud rates are 300, 600, 1200,
2400, 4800, 9600 (default), 19200, 38400, 57600, 115200, 230400, 460800, and
921600 baud.
Baudrate (9600) ? _