Appendix H: DC Connector Instructions
SLC™ Console Manager User Guide
338
3.
Using a small screwdriver, press the slot to release the spring pressure for each conductor (as
shown in
) and insert the wire. When the wire is in position, release the pressure on
the screwdriver to securely capture the wire.
4.
After the leads are installed as shown in
, assemble the strain relief (2 gray pieces)
to the connector plug and snap the connector together as shown in
.
Figure H-3 Plug Parts to Assemble
Caution:
Verify wiring before connecting to the SLC console manager. If the
polarity is reversed, you can damage the SLC internal power supply.
5.
Connect a Digital Volt/OHM (DVOM) meter to the power source leads and verify the (-48 VDC)
power source.
a.
Insert the
RED
(+) lead of the DVOM into the top hole of the connector for the source
power lead.
b.
Then insert the
BLACK
(–) lead of the DVOM into the bottom hole of the connector for the
return power lead as shown in
Figure H-4 Verification of the Power Source
c.
Turn on your power source, the voltage should read (-48.00 VDC ±.5 VDC) as shown in
the DVOM in
6.
With power source off and SLC power switch off, perform the following steps:
a.
Connect the DC power cords to your SLC console server as shown in
Содержание SLC16
Страница 1: ...Part Number 900 449 Revision J July 2014 SLC Console Manager User Guide SLC8 SLC16 SLC32 SLC48 ...
Страница 95: ...8 Device Ports SLC Console Manager User Guide 95 Figure 8 4 Device Ports Settings ...
Страница 150: ...10 USB Port SLC Console Manager User Guide 150 Figure 10 3 Devices USB Modem 3 Enter the following fields ...
Страница 217: ...13 Maintenance SLC Console Manager User Guide 217 Figure 13 1 Maintenance Firmware Config ...