9: Administration
SGX 5150 IoT Device Gateway User Guide
120
TM
To Configure Tunnel Accept Mode Settings
Using Web Manager
To configure the Accept Mode for a specific tunnel, on the
Administration
page, click
Tunnel
> Tunnel 1 > Accept Mode
.
Using the CLI
To enter Tunnel 1 Accept Mode command level:
enable > tunnel 1 > accept
Using XML
Include in your file:
<configgroup name="tunnel accept" instance="1">
Connect Mode
In Connect Mode, the SGX 5150 continues to attempt an outgoing connection on the network, until
established (based on which connection method is selected in the configuration described in
Flush Serial
Set whether the serial line data buffer is flushed upon a new network
connection. Choices are:
Enabled
= serial data buffer is flushed on network connection
Disabled
= serial data buffer is not flushed on network connection (
default
)
Block Serial
Set whether Block Serial is enabled for debugging purposes. Choices are:
Enabled
= if Enabled, incoming characters from the serial line will not be
forwarded to the network. Instead, they will be buffered and will eventually
flow off the serial line if hardware or software flow control is configured.
Disabled
= this is the default setting; incoming characters from the Serial
Line are sent on into the network. Any buffered characters are sent first.
Block Network
Set whether Block Network is enabled for debugging purposes. Choices are:
Enabled
= if Enabled, incoming characters from the network will not be
forwarded to the Serial Line. Instead, they will be buffered and will eventually
flow off the network side.
Disabled
= this is the default setting; incoming characters from the
networkare sent on into the Serial Line. Any buffered characters are sent
first.
Password
Enter a password. This password can be up to 31 characters in length and must
contain only alphanumeric characters and punctuation. When set, clients must
send the correct password string to the unit within 30 seconds from opening
network connection in order to enable data transmission. The password sent to
the unit must be terminated with one of the following:
0A (Line Feed)
00 (Null)
0D 0A (Carriage Return/Line Feed)
0D 00 (Carriage Return/Null)
If,
Prompt for Password
is set to
Enabled
and a password is provided, the
user will be prompted for the password upon connection.
Email on Connect
Select an email profile number to which an email notification will be sent upon
the establishment of an accept mode tunnel.
Email on Disconnect
Select an email profile number to which an email notification will be sent upon
the disconnection of an accept mode tunnel.
Tunnel Accept Mode
Settings (continued)
Description
Содержание SGX 5150
Страница 1: ...Part Number 900 776 R Revision D January 2018 SGX 5150 IoT Device Gateway User Guide TM...
Страница 22: ...2 Introduction SGX 5150 IoT Device Gateway User Guide 22 TM Figure 2 3 Product Label...
Страница 138: ...B Compliance SGX 5150 IoT Device Gateway User Guide 138 TM Figure B 1 EU Declaration of Conformity...