9: Administration
SGX 5150 IoT Device Gateway User Guide
116
TM
Using XML
Include in your file:
<configgroup name="terminal" instance="1">
Tunnel
Tunneling allows serial devices to communicate over a network without ‘being aware’ of the
devices that establish the network connection between them. Tunneling parameters are
configured using the Tunnel menu and submenus. The Tunnel settings allow you to configure how
the Serial-Network tunneling operates. Tunneling is available on all serial lines. The connections
on one serial line are separate from these on another serial port.
Note:
The following section describes the steps to view and configure Tunnel 1 settings;
these steps apply to other tunnel instances of the SGX 5150 gateway.
Tunnel Statistics
Tunnel statistics contains data counters, error counters, connection time and connection
information. Statistics are available at each individual connection and aggregated across all
connections.
To View Tunnel Statistics
Using Web Manager
To view statistics for a specific tunnel, on the
Administration
page, click
Tunnel
>
Tunnel 1 >
Statistics
.
Using the CLI
To view Tunnel 1 statistics:
enable > tunnel 1, show statistics
Using XML
Include in your file:
<statusgroup name=”tunnel” instance=”1”
>
Serial Settings
These serial settings for the tunnel apply to the Serial Line interface. The Line Settings and
Protocol are displayed for informational purposes and must be configured from the Line settings.
Table 9-47 Tunnel Serial Settings
Terminal Serial
Settings
Description
Line Settings
Line Settings information here is display only. Go to the section,
the Terminal Line or USB Connection
to modify these settings.
Protocol
Protocol information here is display only. Go to the section,
Terminal Line or USB Connection