5: Configuration Using
Web Manager
Disconnect Mode Settings
Description
Check EOT (Ctrl-D)
Select
Yes
to drop the connection when
Ctrl-D
or
Hex 04
is
detected. Both
Telnet Com Port Cntrl
and
Check EOT
(Ctrl+ D)
must be enabled for
Disconnect with EOT
to function
properly.
Ctrl+D
is only detected going from the serial port to the
network. The default setting is
No
.
Inactivity Timeout
Use this parameter to set an inactivity timeout. The unit drops the
TCP connection to port 10001/10002* if there is no activity on the
serial line before the set time expires. Enter time in the format
mm:ss, where m is the number of minutes and s is the number of
seconds. To disable the inactivity timeout, enter 00:00.
Note*:
The default port number for Port 1 is 10001 and 10002 for
Port 2. However, port numbers may be set to a different value.
3.
When you are finished, click the
OK
button.
4.
On the main menu, click
Apply Settings
.
Connection Settings - UDP
To configure a channel’s UDP settings:
1.
On the main menu, click
Connection
. The Connection Settings window for the selected
channel displays.
2.
In the available fields, enter or modify the following information:
Figure 5-8. UDP Connection Settings
Micro125 User Guide