5: Configuration Using
Web Manager
Endpoint Configuration
Endpoint Configuration
Settings
Description
Local Port
Enter the local port number.
Auto increment for active
connect
Select to auto-increment the local port number for new outgoing
connections. The range of auto-incremented port numbers is
50,000
to
59,999
and loops back to the beginning when the
maximum range is reached.
Remote Port
Enter the remote port number.
Remote Host
Enter the IP address of the remote device.
Common Options
Common Option Settings
Description
Telnet Com Port Cntrl
This field is available for configuration only when
Active
Connect
is set to
None
. Select
Enable
to permit Telnet communication to
the unit. The
Telnet Com Port Cntrl
feature is used in
conjunction with the Com Port Redirector (CPR) utility. (See the
CPR Online Help
for details.)
Terminal Name
This field is available for configuration only when Telnet Mode is
set to
Enable
.
Use the terminal name for the Telnet terminal type. Enter only
one name. When this option is enabled, the unit also reacts to the
end of record (EOR) and binary options, which can be used for
applications such as terminal emulation to IBM hosts.
Connect Response
A single character is transmitted to the serial port when there is a
change in connection state. Default setting is
None
.
Use Hostlist
If this option is set to
True
, the device server scrolls through the
host list until it connects to a device listed in the host list table.
Once it connects, the unit stops trying to connect to any others. If
this connection fails, the unit continues to scroll through the table
until it connects to another IP in the host list.
The host list is disabled for Manual Mode and for Modem Mode.
The unit will not accept a data connection from a remote device
when the host list option is enabled.
LED
Select
Blink
for the status LEDs to blink upon connection or
None
for no LED output.
Disconnect Mode
Disconnect Mode Settings
Description
On Mdm_Ctrl_In Drop
Set to
Yes
for the network connection to or from the serial port to
disconnect (drop) when
Modem Control
In transitions from an
asserted state to not asserted state. The default setting is No.
Hard Disconnect
When set to
Yes
, the TCP connection closes even if the remote
site does not acknowledge the disconnect request.
Micro125 User Guide
31