Parameter description:
LLDP Parameters
Tx Interval
The switch periodically transmits LLDP frames to its neighbours for having
the network discovery information up-to-date. The interval between each
LLDP frame is determined by the Tx Interval value. Valid values are
restricted to 5 - 32768 seconds.
Tx Hold
Each LLDP frame contains information about how long the information in
the LLDP frame shall be considered valid. The LLDP information valid
period is set to Tx Hold multiplied by Tx Interval seconds. Valid values are
restricted to 2 - 10 times.
Tx Delay
If some configuration is changed (e.g. the IP address) a new LLDP frame is
transmitted, but the time between the LLDP frames will always be at least
the value of Tx Delay seconds. Tx Delay cannot be larger than 1/4 of the Tx
Interval value. Valid values are restricted to 1 - 8192 seconds.
Tx Reinit
When a port is disabled, LLDP is disabled or the switch is rebooted, an
LLDP shutdown frame is transmitted to the neighboring units, signalling that
the LLDP information isn't valid anymore. Tx Reinit controls the amount of
seconds between the shutdown frame and a new LLDP initialization. Valid
values are restricted to 1 - 10 seconds.