background image

 

110

 

3.2.7  Command: LLDP > statistics 

Parameter: N/A 

Description: display the detail information of LLDP settings 

Example: 

3.3  Port 

Command: port 

Parameter:  N/A 

Description: Enter the port mode 

Example: 

 

111

 

 

3.3.1  Command: port  > configuration 

Parameter:  N/A 

Description: display the setting of each port 

Example: 

3.3.2  Command: port  > status 

Parameter:  N/A 

Description: display the connection status of each port 

Example: 

Содержание IPES-3408 Series

Страница 1: ...r help CE Mark Warning This is a Class A product In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures 1 Chapter 1 Introd...

Страница 2: ...l Red Ethernet port Link Activity Green Speed Green Mini GBIC Link Activity Green Power Supply 48 56VDC Redundant power input with 1500VDC isolation 48VDC is single power input Power Consumption 10Wat...

Страница 3: ...vise its identification and capability on the LAN 5 CDP Cisco Discovery Protocol for topology mapping PoE Management PoE Detection to check if PD is hang up then restart the PD PoE Scheduling to On OF...

Страница 4: ...ll of packet type Ingress filter packet type combination rules are Broadcast Multicast Flooded Unicast packet Broadcast Multicast packet Broadcast packet only and all types of packet The packet filter...

Страница 5: ...ng of 128 byte assigned as its own unique name via the SNMP or CLI interface 9 Chapter 2 Hardware Description information and wiring installation 2 1 Physical Dimension 65 W x 105 D x 152 H mm 2 2 Fro...

Страница 6: ...n of the LED status and their meanings for the switch LED Color Status Meaning PWR Green On The switch unit is power on Off No power PWR1 Green On Power 1 is active Off Power 1 is inactive PWR2 Green...

Страница 7: ...ht up Please refer to the LED Indicators section for indication of LED lights 5 Prepare the twisted pair straight through Category 5 cable for Ethernet connection 6 Insert one side of RJ 45 cable cate...

Страница 8: ...ow the steps below to mount the industrial switch with wall mount plate 1 Remove the DIN Rail from the industrial switch loose the screws to remove the DIN Rail 2 Place the wall mount plate on the rea...

Страница 9: ...WG 17 3 5 Wiring the Fault Alarm Contact The fault alarm contacts are in the middle of the terminal block connector as the picture shows below Inserting the wires the switch will detect the fault stat...

Страница 10: ...itch the connection speed between 100 and 1000Mbps They are used for connecting to the network segment with single or multi mode fiber You can choose the appropriate SFP transceiver to plug into the s...

Страница 11: ...ransceiver please follow the steps shown below First press the upper side of the LC connector to release from the transceiver and pull it out Remove LC connector Second push down the metal loop and pu...

Страница 12: ...v2 draft The benefits of G 8032 are 1 50ms recovery time when failover 2 G 8032 is the standard protocol which can interact amongst different brands without being tie up by the same supplier to ensure...

Страница 13: ...24 Multiple Rings 2 1 Dual Rings 2 2 Multiple Rings Dual Homing 25 Chain 4 1 Single Chain 4 2 Multiple Chains 4 3 Multiple Chains Share Common Ends 4 4 Cascade Chain...

Страница 14: ...5 connector Attach the end of RS 232 connector to PC or terminal and the other end of RJ 45 connector to the console port of the switch The connected terminal or PC must support the terminal emulation...

Страница 15: ...configuration and functions of the Web Based management 6 1 About Web based Management There is an embedded HTML web site residing in flash memory on CPU board of the switch which offers advanced mana...

Страница 16: ...name A domain name is a text string drawn from the alphabet A Za z digits 0 9 minus sign No space characters are permitted as part of a name The first or last character must not be a minus sign The a...

Страница 17: ...IPV6 standard of switch in here Network Mask The network mask of IP address Default Gateway The IP address of network gateway if you need switch to connect with internet please input correct IP addres...

Страница 18: ...ence 35 Local Time Zone Conversion from UTC Time at 12 00 UTC November Time Zone 1 hour 11am Oscar Time Zone 2 hours 10 am ADT Atlantic Daylight 3 hours 9 am AST Atlantic Standard EDT Eastern Daylight...

Страница 19: ...Standard USSR Zone 9 10 hours 10 pm IDLE International Date Line NZST New Zealand Standard NZT New Zealand 12 hours Midnight Clock Source You can set Manual to set the time of switch manually or set...

Страница 20: ...r Both Authentication Protocol Set the authenticated way the default value was MD5 Authentication Password Set the password of authentication Privacy protocol Set the security way the default value wa...

Страница 21: ...og Server Save log to Syslog Server Email Action Email Alert Sent log via Email 41 SMS Action SMS Alert Sent log via SMS service The user must let the switch connect with internet and define the SMS s...

Страница 22: ...y the host computer They provide messages which can be applied to heaters pumps and other electrical equipment The digital inputs may be read by the host computer and used to sense the state of a remo...

Страница 23: ...lectrical signal of Low to High when the condition of the ticked checkbox is met port power failure occurs 6 4 8 Environment Monitoring Environment Monitoring You can see the hardware status of switch...

Страница 24: ...rces the cu port in 100Mbps full duplex mode 1Gbps FDX Forces the cu port in 1Gbps full duplex mode 6 5 2 Port Status 47 Port No This is the logical port number for this row Type This is the logical p...

Страница 25: ...th RX and TX traffic which come from source port Source Port The ports that user wants to monitor All monitored port traffic will be copied to mirror destination port 49 Port Rate Limiting You can set...

Страница 26: ...aximum power available the switch will offer the power to the high priority PoE port and stop to supply power to the low priority PoE port Power Limit Set the Maximum power of each PoE port 51 Power C...

Страница 27: ...switch 53 6 7 Topology This function can help the user build the network topology drawing of field in switch please remember to enable LLDP function before you using this application Topology Status...

Страница 28: ...54 Graphic View Display each switch in your network by graphic You can see the topology diagram which build by the LLDP information in here 55 Demo Demo display each topology in different application...

Страница 29: ...level 25 is 7 The port 1 is following the ToS priority policy 57 only When the packet received by port 1 the system will check the ToS value of the received IP packet If the ToS value of received IP...

Страница 30: ...IP address which you want to deny Mask set the mask to filter the IP range 59 6 9 3 IEEE 802 1X Radius Server 802 1X makes use of the physical access characteristics of IEEE802 LAN infrastructures in...

Страница 31: ...e the switch through the Web browser 61 6 10 VLAN The VLAN membership configuration for the switch can be monitored and modified here Up to 4094 VLANs are supported This page allows for adding and del...

Страница 32: ...ross switches PVID Indicates the VLAN ID of this particular VLAN Tagged VID This column field is available when Link Type is set as Trunk Link and Hybrid Link Assign a number in the range between 1 an...

Страница 33: ...d from neighbors but will send out LLDP information Disabled The switch will not send out LLDP information and will drop LLDP information received from neighbors Both The switch will send out LLDP inf...

Страница 34: ...Many Neighbours in the LLDP standard LLDP frames require a new entry in the table when the Chassis ID or Remote Port ID is not already contained within the table Entries are removed from the table whe...

Страница 35: ...Value If a TLV is malformed it is counted and discarded TLVs Unrecognized The number of well formed TLVs but with an unknown type value 69 6 13 IGMP Snooping This page provides IGMP Snooping related...

Страница 36: ...ted stack unit as reflected by the page header Statistics VLAN ID The VLAN ID of the entry 71 Status Querier Shows the Querier status is ACTIVE or IDLE DISABLE denotes the specific interface is admini...

Страница 37: ...formation about how long the information in the CDP frame shall be considered valid The holdtime between each CDP frame is determined by the Tx Holdtime value Valid values are restricted to 5 32768 se...

Страница 38: ...for higher layer entities to assist discovery by the network management This could for instance hold the neighbor s IP address 75 6 14 MSTP 6 14 1 MSTP Global Configuration Mode You can choose STP or...

Страница 39: ...region It defines how many bridges a root bridge can distribute its BPDU information to Valid values are in the range 6 to 40 hops How to enable MSTP 6 14 1 1 Enter MSTP CIST Settings press icon to en...

Страница 40: ...e port priority This can be used to control priority of ports having identical port cost See above edge_mode Controls whether the operEdge flag should start as being set or cleared The initial operEdg...

Страница 41: ...on the least cost path to the Root Bridge Topology State The current state of the Topology Change Flag of this Bridge instance Topology Change Last The time since last Topology Change occurred 81 6 1...

Страница 42: ...3 6 15 2 LACP Port Status Trunking Group Number of trunking group LACP Yes means that LACP is enabled and the port link is up No means that LACP is not enabled or that the port link is down Backup mea...

Страница 43: ...give a specific switch priority over other identical switches The range for both is from 0 to 255 The default is 255 Announce Interval Specify the time for sending announce messages The range is 0 to...

Страница 44: ...1 2 Press icon to add one ring with G 8032 protocol PS in this case we will use the port9 and port10 of each switch to build a ring 87 6 16 1 3 Enter edit mode 6 16 1 4 There are 3 switches in the rin...

Страница 45: ...ID The ID of the created Protection group State ERPS state according to State Transition Tables in G 8032 Role It can be either RPL owner or RPL Neighbour Ring Port 0 true ring port 0 is blocking fal...

Страница 46: ...he switch to the startup configuration on this page The new startup configuration is not available immediately which means that restart the switch is necessary 91 Reset to default You can reset the co...

Страница 47: ...e file which on your desktop 6 18 5 Diagnostics PING Address Set the IP address which you want to ping Count Set the times of Ping Packet Size set the size of Ping packet 93 ARP Table You can find the...

Страница 48: ...still cannot resolve the problem contact the local dealer for assistance If the LED indicators are normal and the connected cables are correct but the s 95 Appendix A RJ 45 Pin Assignment RJ 45 Pin A...

Страница 49: ...se TX cable schematic Straight through cable schematic Cross over cable schematic 10 100 1000Base TX Pin outs The following figure shows the 10 100 1000 Ethernet RJ 45 pin outs 10 100 1000Base TX Cabl...

Страница 50: ...ation parameters to match the following default characteristics of the console port Baud Rate 115200 bps Data Bits 8 Parity none Stop Bit 1 Flow control None The settings of communication parameters O...

Страница 51: ...ket was set as 23 all the commands under Telnet mode were the same as the Console mode 3 Commands 3 1 System Command system Parameter N A Description Enter the system mode Example 101 3 1 1 Command sy...

Страница 52: ...1 5 Command system description Parameter N A Description display or fix the system description Example 103 3 1 6 Command system DHCPclient Parameter enable disable Description enable or disable DHCP c...

Страница 53: ...v6 Example 105 3 1 12 Command system reboot Parameter N A Description reboot the switch Example 3 1 13 Command system restoredefault Parameter keep_none restore all setting keep_all restore all but ke...

Страница 54: ...t import export or import the setting of switch URL set the destination which save load the setting file support both the TFTP and FTP protocol Description export or import the setting of switch Examp...

Страница 55: ...th dedicated port enabledRxOnly enable Rx only of LLDP function with dedicated port disabled disable LLDP function with dedicated Description enable LLDP function of each port Example 109 3 2 4 Comman...

Страница 56: ...settings Example 3 3 Port Command port Parameter N A Description Enter the port mode Example 111 3 3 1 Command port configuration Parameter N A Description display the setting of each port Example 3 3...

Страница 57: ...mand port description Parameter N A Description display the description of each port Example 113 3 3 5 Command port speed Parameter N A Description display the speed of each port Example 3 3 6 Command...

Страница 58: ..._uni uni_broad_multi Description set the ingress rate of the dedicated port with specified packet Example 115 3 3 8 Command port egressrate Parameter port_list choose which port you want to set the in...

Страница 59: ...116...

Отзывы: