18
PD devices required.
Non-PoE model (M12)
PoE model (M23)
Pin assignment of Power input
Dual Power Input
The power input can be supported redundantly. The supply voltage is
electrically isolated from the housing.
Note:
With single power supply of the mains voltage, the device will
report a power failure. You can disable this power fail event via web
browser.
Pin assignment of alarm relay
A break in contact is reported via the relay contact :
The failure of at least one of the two supply voltages.
The break link status of at least one switch port.