TF1100-EH transit-time handheld flowmeter manual
19
(7) Butane at 0
℃
(8)Other liquids (9) Diesel Oil (10)Castor Oil
(11)Peanut Oil (12) #90 Gasoline (13) #93 Gasoline (14) Alcohol
(15) Hot water at 125
℃
M21
Window for entering the fluid sound speed only for non-standard liquids, i.e.,
in Menu20, user select “8, Other Liquids”.
M22
Window for entering the viscosity of the non-standard liquids
M23
Window for selecting the proper transducers (XDCR)types:
There are different types of transducers
for TF1100-EH,
options: Standard-M, Standard-S, standard-L,
TF1100-EC is Plug-in type B45.
Standard-S: Clamp-on small pipe, 15-40mm
Standard-M: Clamp-on standard pipe, 40-1200mm
Standard-L: Clamp-on large pipe, 1000mm-4500mm
Plug-in B45: Insertion, hot-tapped transducer, 65-4500mm
M24
Window for selecting the transducer mounting methods
Four methods can be selected:
(0) V-method (1) Z-method (2) N-method (3) W-method
M25
Display the transducer mounting spacing.
M26
Entry to store the parameter configuration into the internal memory. this
menu is not useful for common application.
M27
Entry to load one set of saved parameters, this menu is not useful for
common application.
M28
Select YES or NO for the instrument to determine whether or not to hold (or
to keep) the last correct value when poor signal condition occurs. YES is the
default setup
M29
Empty Pipe Setup, this is very useful for user, Empty pipe line or pipe
shaking etc., meter may display error or undesired read, user can setup a Q
value less than normal Q value, for example, normal Q value is 60-70, user
can enter Empty Pipe Setup value 50, such, meter will display 0 flow rate
when Q value is less than 50. In good pipe status, please do not setup this
value too small.
M30
Window for selecting unit system. Default value is ‘Metric’. The change
from English to Metric or vice versa will not affect the unit for totalizers.
M31
Window for selecting flow rate that will be used by the instrument afterward.
Flow rate can be in:
0. Cubic Meter short for (m3)
1. Liter (l)
2. USA Gallon (gal)
3. Imperial Gallon (igl)
4. Million USA Gallon (mgl)
5. Cubic Feet (cf)
6. USA Liquid Barrel (bal)
7. Imperial Liquid Barrel (ib)
8. Oil Barrel (ob)
The flow unit in terms of time can be per day, per hour, per minute or per
M23
XDCR Type
0. Standard-M