UL File E8138
Rev. A 2002
9
INSTALLATION
DANGER
THIS APPLIANCE MUST BE GROUNDED AT THE TERMINAL PROVIDED.
FAILURE TO GROUND THE APPLIANCE COULD RESULT IN
ELECTROCUTION AND DEATH.
WARNING
INSTALLATION OF THE UNIT MUST BE DONE BY PERSONNEL
QUALIFIED TO WORK WITH ELECTRICITY AND PLUMBING. IMPROPER
INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND/OR DAMAGE
TO EQUIPMENT. UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL
APPLICABLE CODES.
NOTICE
The data plate is located behind the screened door under the control
panel. The oven voltage, wattage, serial number, wire size, and clearance
specifications are on the data plate. This information should be carefully
read and understood before proceeding with the installation.
NOTICE
The installation of any components such as a vent hood, grease
extractors, fire extinguisher systems, must conform to their applicable
National, State and locally recognized installation standards.
ELECTRICAL CONNECTION
Install the legs to the oven.
Electrical service connections can be made through an 11/4 knockout in the bottom
of the oven below the electrical controls.
Remove the cover attached to the oven circuit breakers for access.
Power connections can be made to the wires extending from the bottom of the
circuit breakers. Each wire has three numbers approximately two feet apart.
For Service connection and Phasing refer to the wiring diagram located at the back
of this manual.
Pull the wires out the front. Observe the three sets of numbers. Cut the wires as
indicated:
1.
For bottom deck or single deck installations cut each wire 3-inches below
numbers 1; 2; 3; 4.
2.
For middle deck or double deck installations cut each wire 3-inches below
numbers 5; 6; 7; 8.
3.
For top deck or triple deck installations cut each wire 3-inches below numbers
9; 10; 11; 12.
Place second oven on top of bottom oven and route the four wires through the
bushing of the lower oven. They should now be in proximity of the wires from the
bottom deck.
A single power connection can now be made at the bottom deck. Through the
hinged door of the bottom oven, group and tape together the wires as indicated in
the service connection chart located in the wiring diagram at the end of this manual.