background image

 

13

 

TROUBLESHOOTING CONT’D 

9.2 TESTS 
NOTICE:

 

Service on this, or any other, LANG appliance must be 
performed by qualified personnel only.  Consult your 
LANG authorized service agent directory or call the 
factory at 1-800-807-9054 or 

WWW.STAR-MFG.COM

   

For the service agent nearest you. 

WARNING:

 

BOTH HIGH AND LOW VOLTAGES ARE PRESENT 
INSIDE THIS APPLIANCE WHEN THE UNIT IS 
PLUGGED/WIRED INTO A LIVE RECEPTACLE.  
BEFORE REPLACING ANY PARTS, DISCONNECT THE 
UNIT FROM THE ELECTRIC POWER SUPPLY. 

If an item on the list is followed by an asterisk (*), the work should be done by a factory 
authorized service representative. 

 

 

Possible Cause 

TEST 

Product is cooked too long 

 

No test available, operational condition 

Failed thermostat 

 

Check thermostat for continuity, or that it is 
cycling on & off 

Failed element 

 

Remove the wires and check for proper 
resistance across the element  

 

CAUTION:

   

  USE OF ANY REPLACEMENT PARTS OTHER THAN 

THOSE SUPPLIED BY LANG OR THEIR AUTHORIZED 
DISTRIBUTORS CAN CAUSE BODILY INJURY TO THE 
OPERATOR AND DAMAGE TO THE EQUIPMENT AND 
WILL VOID ALL WARRANTIES.

 

 

 

 

Содержание CL36GF

Страница 1: ...10 Sunnen Drive St Louis MO 63143 Part Number 2M W362 Phone 314 781 2777 Fax 314 781 2714 Rev A WWW STAR MFG COM May 16 2007 Installation Operation and Maintenance Troubleshooting Electric Marine Cruise Line Griddle Model CL36GF CL48GF ...

Страница 2: ...SERVICE OR MAINTENANCE CAN CAUSE PROPERTY DAMAGE INJURY OR DEATH READ THE INSTALLATION OPERATING AND MAINTENANCE INSTRUCTIONS THOROUGHLY BEFORE INSTALLING OR SERVICING THIS EQUIPMENT NOTICE THIS EQUIPMENT IS APPROVED FOR INSTALLATION ONLY ON VESSELS GREATER THAN 65 FEET IN LENGTH IN ACCORDANCE WITH USCG REGULATIONS IN TITLE 46 CFR 110 113 ANY WIRING USED IN THE INSTALLATION OF THIS APPLAINCE MUST ...

Страница 3: ...NTS CHAPTER PAGE 1 TABLE OF CONTENTS 3 2 READ FIRST 4 3 UNPACKING 6 4 INSTALLATION 7 5 INITIAL START UP 9 6 OPERATION 10 7 MAINTENANCE CLEANING PROCEDURES 11 8 TROUBLESHOOTING 12 9 PARTS LISTS 14 10 WIRING DIAGRAMS 15 ...

Страница 4: ...RICITY IMPROPER INSTALLATION CAN CAUSE INJURY TO PERSONNEL AND OR DAMAGE TO EQUIPMENT UNIT MUST BE INSTALLED IN ACCORDANCE WITH ALL APPLICABLE CODES NOTICE The data plate is located behind the access panel in the back of the griddle If on a 48 or larger the data plate is behind the back left access panel The griddle voltage wattage serial number wire size and clearance specifications are on the da...

Страница 5: ...e on this or any other LANG appliance must be performed by qualified personnel only Consult your LANG authorized service agent directory or call the factory at 1 800 807 9054 or WWW STAR MFG COM for the service agent nearest you WARNING BOTH HIGH AND LOW VOLTAGES ARE PRESENT INSIDE THIS APPLIANCE WHEN THE UNIT IS PLUGGED WIRED INTO A LIVE RECEPTACLE BEFORE REPLACING ANY PARTS DISCONNECT THE UNIT F...

Страница 6: ... as near its intended location as practical The crating will help protect the unit from the physical damage normally associated with moving it through hallways and doorways 3 3 Un crating The griddle will arrive completely assembled inside a wood frame covered by cardboard box and strapped to a skid Remove the cardboard cover cut the straps and remove the wood frame Remove griddle from skid and pl...

Страница 7: ...ot griddles There are two power supply connections on 5 and 6 foot griddles Refer to the power supply chart on the next page for proper power supply size There is 1 one 1 1 4 inch conduit knockout on 2 3 and 4 foot griddles located at the rear of the griddle through the back and the bottom of the griddle body There are 2 two 1 1 4 inch conduit knockouts provided on the 5 and 6 foot griddles Use a ...

Страница 8: ...115 2 100 0 515 CL60GF 1 18 0 50 0 50 0 50 0 43 3 43 3 43 3 21 7 21 7 21 7 86 5 75 0 625 CL60GF 2 12 0 50 0 28 8 28 8 43 3 25 0 25 0 21 7 12 5 12 5 57 7 50 0 625 CL72GF 1 18 0 50 0 50 0 43 3 43 3 43 3 43 3 21 7 21 7 21 7 86 5 75 0 735 CL72GF 2 18 0 50 0 50 0 43 3 43 3 43 3 43 3 21 7 21 7 21 7 86 5 75 0 735 PHASING BY WIRE NUMBER THREE PHASE SINGLE PHASE MODEL NUMBER LINE 1 LINE 2 LINE 3 LINE 1 LIN...

Страница 9: ...hours at 200 F 93 C degrees proceed with SEASON THE COOKING SURFACE 5 2 Season the Grill The cooking surface must be seasoned in order to reduce product sticking To season heat the griddle to 250 F 121 C degrees Once at 250 F 121 C degrees coat the cooking surface with a non salted vegetable oil Allow the griddle to stand at 250 F 121 C degrees until the cooking surface looks dry then coat it agai...

Страница 10: ...ooking section If product is loaded directly over the temperature sensor that section will turn on and the element will heat the entire cooking section If the product is loaded to the side front or back of the temperature sensor the controller will react to the temperature change of the entire section instead of just one product During slow periods minimal loads do not load directly over the tempe...

Страница 11: ...erior of the appliance with hot water and mild detergent to maintain a gleaming appearance Keep the griddle surface clean After each cooking load scrape the griddle surface with a griddle scraper to remove any carbonized grease 7 2 Weekly or as Required Once a week or when necessary the griddle surface should be cleaned and re seasoned Use a griddle stone griddle pad or liquid cleaner Rub with the...

Страница 12: ...n to the Possible Cause for the items to be checked To test for a possible cause refer to the TEST section and locate the Possible Cause then refer to test to identify test procedures SYMPTOM POSSIBLE CAUSE Griddle will not heat Failed element Failed thermostat No power to cord outlet Open wire Product burning Product is cooked too long Failed thermostat Product under done Failed thermostat ...

Страница 13: ...RTS DISCONNECT THE UNIT FROM THE ELECTRIC POWER SUPPLY If an item on the list is followed by an asterisk the work should be done by a factory authorized service representative Possible Cause TEST Product is cooked too long No test available operational condition Failed thermostat Check thermostat for continuity or that it is cycling on off Failed element Remove the wires and check for proper resis...

Страница 14: ... 550o 48 C T 3 CL36GF 440V K9 LGCL 425 ELEMENT PAN 3 CL36GF 440V K9 LGCL 723 31 GRDL PLT WELD 3 ACU PB 1 CL36GF 440V CL48GF Electric Marine Cruise Line Griddle Part No Description QTY Application 2A 72500 05 LEG 4 W BOLT DOWN ADJ 4 CL48GF 440V 2D 73800 01 WATER PAN 1 3 HOTEL 1 CL48GF 440V 2E 30500 11 TRM BLOCK 2 PLE LG 175AMP 2 CL48GF 440V 2F 50404 08 1 LG PLT 1X47 7 8X22 15 16 1 CL48GF 440V 2H XL...

Страница 15: ...15 WIRING DIAGRAM ...

Отзывы: