E1/G.703 F
IBER
O
PTIC
M
ODEM
O
PERATING
M
ANUAL
IOA76-1F
35
May 2009
Figure 26.
Channel activity
6.3 G.826
statistics
This tab enables the user to monitor the following numbers in 15-minut and 24-hour
periods:
•
ES errored seconds,
•
SES severely errored seconds,
•
EB errored bloks,
•
UAS unavailability seconds,
Additionally, you can set threshold values for switching on and off the alarms for SES15,
SES24, ES15, ES24, SESFE15, SESFE24 counters, based on which event log entries and alarms
are generated. Each counter has an associated alarm severity level identifying the type
of a generated alarm.
The user can set the following alarm severity levels:
•
urgent alarm,
•
non-urgent alarm,
•
no alarm.
Содержание MD-76
Страница 42: ...E1 G 703 FIBER OPTIC MODEM OPERATING MANUAL IOA76 1F 36 May 2009 Figure 27 G 826 statistics...
Страница 54: ......
Страница 55: ......