Page A - 33
A
LW SC-300 E / LW SC-350 E
Version: 06.12.2022
R E M E D Y I N G F A U L T S
Final pressure can not be reached
Strong compressor vibration
Cause of fault
Remedy
V-belt tension too loose
Tension V-belt
Drive motor / Compressor unit loosely
Retighten mounting screws
Anti vibration mounts used up
Replace
Ground not levelled
Ensure a solid and level ground
Cause of fault
Remedy
Connections leaky
Retighten or clean/replace if necessary
Final pressure safety valve leaky
Replace
Pipes / heat exchanger broken
Replace
Condensate drain valves leaky
Unscrew valves, check sealing surfaces, clean,
replace if necessary
Final pressure switch stop unit
Verify settings, replace if necessary
Piston of pneumatic condensate valve sticks
Clean pneumatic condensate valve and restore
function, check/replace o-rings, replace valve
completely if necessary
Air supply too low
Cause of fault
Remedy
Inlet and outlet valves contaminated / defective Clean, replace if necessary
Cylinder(s), piston(s) or piston ring(s) used up
Replace
V-belt slips
Tension V-belt
See chapter "Final pressure can not be reached" See chapter "Final pressure can not be reached"
Содержание SC-300 E
Страница 3: ...A Operating Instructions Breathing Air Compressor LW SC 300 E LW SC 350 E Version 12 22 E...
Страница 12: ...A S A F E T Y P R E C A U T I O N S...
Страница 19: ...A I N S TA L L AT I O N...
Страница 21: ...Page A 19 A LW SC 300 E LW SC 350 E Version 06 12 2022 I N S T A L L A T I O N Dimensions Fig Dimensions...
Страница 26: ...A O P E R AT I O N...
Страница 34: ...A R E M E D Y I N G FA U LT S...
Страница 39: ...A M A I N T E N A N C E A N D S E R V I C E...
Страница 67: ...A M A I N T E N A N C E R E C O R D S...
Страница 75: ...E A T T A C H M E N T Version 11 12 E...
Страница 79: ...INFORMATIONON THE SERVICE LIFE OF L W HIGH PRESSURE HOSES...
Страница 87: ...ANNEX...