2-12
F-661-0321
Hydraulic Manifold Installation
1. Lube all O-Ring connections.
2. Fasten Manifold onto Center Frame Bracket with
5/16-18 x 1" Bolts and Lock Washers.
3. Install all other Hydraulic Fittings.
Flow Control Settings (Factory Set)
1. Remove Flow Control Cap and back-off Jam Nut.
Close off Flow Control by turning Allen Wrench CW
until valve bottoms.
2. For initial setting, Open Flow control by turning Allen
Wrench CCW 1 turn. Tighten nut and reinstall Cap.
Fold Shut-Off
To operate wing fold shut-off circuit:
•To close fold shut-off circuit, loosen Jam Nut, turn
valve CW fully until valve bottoms.
•To open fold shut-off circuit, turn valve CCW fully,
tighten Jam Nut.
Figure 2-11: Hydraulic Manifold Installation
Fold Shut-off
Cartridge
Torque to
19-21 Ft-Lbs
Fold Shut-off
Cartridge
181527 Valve
Assembly
176201 Valve
Assembly
Flow Divider/Combiner
Cartridge
Torque to
46-54 Ft-Lbs
Counter Balance
Cartridge
Torque to
35 Ft-Lbs
Relief/Check
Cartridge
Torque to
24-26 Ft-Lbs
Counter Balance
Cartridge
Relief/Check
Cartridge
Flow Control Cartridge
Flow Control
Cartridge
Torque to
24-26 Ft-Lbs
WFP38-46 MANIFOLD MOUNT
Elbow, Long
8MJ x 8MOR
Elbow,
8MJ x 8MOR
Bolt,5/16-18 x 1
Lock Washer,5/16
Valve Assembly
176201 or 181527
Torque to
15-20 Ft-Lbs
Elbow, Long
8MJ x 8MOR
Adapter,
8MJ x 8MOR
Elbow,
8MJ x 8MOR