5-1
Chapter 5
Troubleshooting Guide
For any questions concerning operation or maintenance
of the seeders, refer to the operator’s and parts manuals
as designated in “AVAILABLE SEEDER OPTIONS” on
page 2-1.
Troubleshooting Guide
PROBLEM PROBLEM
CAUSE
SOLUTION
Power LED does not
illuminate
Power fuse blown due to system fault Inspect wire harness for damage or shorts
Replace 15 Amp fuse
Power fuse blown due to tractor fault
Check the power source is 12 Volts DC
Polarity reversed at power lead
connection
Swap power leads to correct terminal
Monitor console fault
Replace or repair console
All indicator LEDs do not
illuminate
Harness disconnected at hitch,
extension or sensors
Check all connections
Harness fuse blown
Inspect wire harness for damage or shorts
Replace 15 Amp fuse
One indicator never
illuminates
Sensor not connected
Check sensor lead
Harness damaged
Check continuity of harness
Sensor failed
Swap sensor from another seed box and
test
No indicator ever
extinguishes
Shafts are not turning
Check seeder drive system
Sensors not correctly installed
Check 1/8 inch gap at sensors
One indicator never
extinguishes
Shaft is not turning
Check section drive system
Seed shaft sensor out of magnet range
Check for 1/8 inch gap at sensors