25
LANDMANN
Trouble shooting
If there is a fault despite due care, this chapter may help you to resolve the malfunction.
Malfunction
Cause
Remedy
There is a smell of gas
Leak in the gas system
1. Close the cylinder valve immediate-
ly (turn operating lever (G2) to a 3
o'clock position).
2. Prevent any flame or spark formati-
on (do not switch on any electrical
appliances)
3. Tighten all connections of the gas
system.
4. Inspect all gas-supplying compo-
nents for signs of external damage;
replace any defective parts with ori-
ginal spare parts
5. Use a leak detection agent to check
the gas system for leaks.
Burner does not light
Gas cylinder is empty
Replace the gas cylinder
Cylinder valve is closed
Turn the operating lever (G2) to a 6
o'clock position
Ignition battery empty
If there is not snap when the ignition
button is pressed, unscrew the ignition
button cap and insert a new battery.
No contact in the ignition cable
Visual check, fit ignition cable if neces-
sary
Gas outlet nozzle is not in the burner Visual inspection; if necessary adjust
burners
Ignition pin next to the burner is
bent
Visual inspection; correct if necessary
Gas outlet nozzle is blocked
Clean the gas outlet nozzle using a pin
Other gas system is blocked
Arrange for a gas specialist to clean the
gas system
Temperature on grill too low
Pre-heating time is too short
Close the lid and set the flame regulator
to Max
Gas outlets on the burner are blo-
cked
Remove blockage from burner