background image

DATA SETTING

Programmer tester Mod. V05

13

fig. 38

MEMORY

DELETION

  MINIMUM RPM

  FOR CUTOFF

    1500 RPM

fig. 34

  POSITION ON

    CUTOFF

    80 STEPS

fig. 35

 FIXED DEFAULT

    OPTION

  NOT ENABLED

fig. 36

 FIXED DEFAULT

 POSITION VALUE

   100 STEPS

fig. 37

MINIMUM RPM FOR CUTOFF

Engine speed at which the cut-off function ends and the central unit repositions the linear actuator with stepper
motor at the default position (fig. 34).
By enabling this function the value of 1500 rpm is suitable for most vehicles.

POSITION ON CUTOFF

This is the position at which the linear actuator with stepper motor positions itself during the cut-off phase. This
value is generally 30 steps less than the default position (fig. 35).

FIXED DEFAULT OPTION

This option keeps the carburation control strategies of a normal default. However, it can be used in emergencies
such as if the lambda sensor has broken or is functioning badly (fig. 36).
In some cases it can be used to force a default more open or more closed consequently making the mixture richer
or leaner.
Caution: This option does not have the function of a fixed register.

FIXED DEFAULT POSITION VALUE

This is the default value set on the basis of the requirements established in the 

FIXED DEFAULT OPTION

(fig. 37). Anyhow, it is the position the linear actuator with stepper motor will take in the conditions of the lambda
sensor being cold or out of order.

MEMORY DELETION

On this “page” the control unit reset procedure is actuated, thereby restoring the factory settings and taking the
default position of the linear actuator with stepper motor back onto 100 steps (fig. 38).
Therefore, in the case of resetting, re-enter the parameters that may have been changed and which
correspond to the vehicle.

Содержание V05

Страница 1: ...PROGRAMMER TESTER Mod V05 190164440 INSTRUCTIONS MANUAL...

Страница 2: ...ON FOR CHANGE OVER pag 8 OVERLAP TIME pag 8 TYPE OF TPS pag 8 INDICATOR SENSOR TYPE pag 9 LAMBDA SENSOR TYPE pag 9 LAMBDA SENSOR READING DELAY pag 9 SIMULATION TYPE pag 10 SQUARE WAVE SIMULATION pag 1...

Страница 3: ...the cursor upwards increases the value and passes on to the previous page C Button that shifts the cursor downwards decreases the value and passes on to the next page D Button to quit the page E Butto...

Страница 4: ...ttle position3 40 240 steps TPS for maximum open throttle3 1 5 5V Maximum actuator position 20 240 steps TPS to release limitation4 0 5V Minimum actuator position 20 240 steps Cutoff option enabled no...

Страница 5: ...DATA DISPLAY Programmer tester Mod V05 5 ARRANGEMENT OF PAGES OF PROGRAMMER TESTER mod V05...

Страница 6: ...essed in volts TPS learning settings the first quadrant indicates the range of engine idling speed the second and third indicate the position of the TPS during cruising speed the fourth indicates when...

Страница 7: ...ttons press the button to confirm the figure fig 9 The parameter is now modified fig 10 If in modify value mode you do not want to confirm the figure just varied pressing the button restores the previ...

Страница 8: ...leration OPTION2 The engine directly starts on gas enabled oany in certain ECUs RPM SELECTION FOR CHANGE OVER Indicates what speed the fuel changeover from petrol to gas must be made at fig 15 OVERLAP...

Страница 9: ...r it is type A or B To measure the voltage on the lambda sensor wire you need to cut the sensor wire and measure the voltage on the wire reaching the vehicle s original control unit with the panel swi...

Страница 10: ...r with a disconnected lambda sensor signal Some computers on receiving the disconnected lambda sensor will ignore it leaving the carburation on petrol unaltered and engine check light switched off Thi...

Страница 11: ...check the two possible conditions carburation too lean or carburation too rich Afterwards check at what number of steps of the linear actuator with stepper motor the lambda sensor oscillates regularly...

Страница 12: ...s the minimum opening position of the linear actuator with stepper motor under which it cannot work fig 32 It is recommended to set this value if the lambda sensor responds in an inadequate manner res...

Страница 13: ...rategies of a normal default However it can be used in emergencies such as if the lambda sensor has broken or is functioning badly fig 36 In some cases it can be used to force a default more open or m...

Страница 14: ...unit permanently also when there is no supply voltage After effecting action to resolve the problem it is necessary to zero the memory of the diagnosis function To zero the memory you need to positio...

Страница 15: ...AY page With the car stationary pass on to gas and accelerate and decelerate a few times with gaps of a few seconds in between in this way the central unit will learn the TPS idling position To learn...

Страница 16: ...50 APPROVED BY BVQI Accredited by the Dutch Council for Certification LANDI RENZO S p A via Fratelli Cervi 75 2 42100 Reggio Emilia ITALY Tel 39 0522 382678 Telex 531050 RELAND Fax 39 0522 382906 E ma...

Отзывы: