DATA DISPLAY

6

       

Landi Renzo S.p.A.

DATA DISPLAY PAGE

To enter the data display page, select 

DISPLAY

 and press 

=

.

On this page it is possible to display the following information (fig. 5):

MOT

: indicates the position in real time of the linear actuator with the stepper motor (value in steps).

DEF

: is the position acquired by default of the linear actuator with the stepper motor.

RPM

: speed of the engine in real time.

TPS

: indicates the position of the TPS expressed in volts.

[]]]

: TPS learning settings.

[]]]

: the first quadrant indicates the range of engine idling speed.

][]]

]][]

: the second and third indicate the position of the TPS during cruising speed.

]]][

: the fourth indicates when the TPS detects the position.

M ]]][]]] R

: indicates the type of signal detected by the lambda sensor.

When the cursor is in position 

L []]]]]] R

 it indicates that the mixture measured by the lambda sensor is

LEAN

.

When the cursor is in position 

L ]]]]]][ R

 the mixture measured by the lambda sensor is 

RICH

.

Pressing the 

/

 button takes you back to the 

MAIN MENU

 page.

    MAIN MENU

 ^ DISPLAY

   SETTING

   DIAGNOSIS

 MOT 80  DEF 80

 RPM 800

 TPS 1.8 V  ][]]

   L ]]][]]] R

Main menu, fig. 4

Display menu, fig. 5

Содержание V05

Страница 1: ...PROGRAMMER TESTER Mod V05 190164440 INSTRUCTIONS MANUAL...

Страница 2: ...ON FOR CHANGE OVER pag 8 OVERLAP TIME pag 8 TYPE OF TPS pag 8 INDICATOR SENSOR TYPE pag 9 LAMBDA SENSOR TYPE pag 9 LAMBDA SENSOR READING DELAY pag 9 SIMULATION TYPE pag 10 SQUARE WAVE SIMULATION pag 1...

Страница 3: ...the cursor upwards increases the value and passes on to the previous page C Button that shifts the cursor downwards decreases the value and passes on to the next page D Button to quit the page E Butto...

Страница 4: ...ttle position3 40 240 steps TPS for maximum open throttle3 1 5 5V Maximum actuator position 20 240 steps TPS to release limitation4 0 5V Minimum actuator position 20 240 steps Cutoff option enabled no...

Страница 5: ...DATA DISPLAY Programmer tester Mod V05 5 ARRANGEMENT OF PAGES OF PROGRAMMER TESTER mod V05...

Страница 6: ...essed in volts TPS learning settings the first quadrant indicates the range of engine idling speed the second and third indicate the position of the TPS during cruising speed the fourth indicates when...

Страница 7: ...ttons press the button to confirm the figure fig 9 The parameter is now modified fig 10 If in modify value mode you do not want to confirm the figure just varied pressing the button restores the previ...

Страница 8: ...leration OPTION2 The engine directly starts on gas enabled oany in certain ECUs RPM SELECTION FOR CHANGE OVER Indicates what speed the fuel changeover from petrol to gas must be made at fig 15 OVERLAP...

Страница 9: ...r it is type A or B To measure the voltage on the lambda sensor wire you need to cut the sensor wire and measure the voltage on the wire reaching the vehicle s original control unit with the panel swi...

Страница 10: ...r with a disconnected lambda sensor signal Some computers on receiving the disconnected lambda sensor will ignore it leaving the carburation on petrol unaltered and engine check light switched off Thi...

Страница 11: ...check the two possible conditions carburation too lean or carburation too rich Afterwards check at what number of steps of the linear actuator with stepper motor the lambda sensor oscillates regularly...

Страница 12: ...s the minimum opening position of the linear actuator with stepper motor under which it cannot work fig 32 It is recommended to set this value if the lambda sensor responds in an inadequate manner res...

Страница 13: ...rategies of a normal default However it can be used in emergencies such as if the lambda sensor has broken or is functioning badly fig 36 In some cases it can be used to force a default more open or m...

Страница 14: ...unit permanently also when there is no supply voltage After effecting action to resolve the problem it is necessary to zero the memory of the diagnosis function To zero the memory you need to positio...

Страница 15: ...AY page With the car stationary pass on to gas and accelerate and decelerate a few times with gaps of a few seconds in between in this way the central unit will learn the TPS idling position To learn...

Страница 16: ...50 APPROVED BY BVQI Accredited by the Dutch Council for Certification LANDI RENZO S p A via Fratelli Cervi 75 2 42100 Reggio Emilia ITALY Tel 39 0522 382678 Telex 531050 RELAND Fax 39 0522 382906 E ma...

Отзывы: