manualshive.com logo in svg
background image

LANDA SEHW  •  8.913-932.0   •  Rev. 02/12a

17

 

 PRESSURE 

W

ASHER  

OPERA

TOR’S MANU

AL
  

MAINTENANCE & SERVICE

CAUTION:  Periodic  inspection  is  recommended  to 
insure that the fuel solenoid valve functions properly. 
This can be done by operating the machine and check-
ing to see that when the trigger on the spray gun is in 
the off position, the burner is not firing.

Fuel Pressure Adjustment:

To  adjust  fuel  pressure,  turn  the  pressure  adjusting 
screw clockwise to increase, counterclockwise to de-
crease. Do not exceed 200 psi. 

NOTE: When changing 

fuel pump, a by-pass plug must be installed in return 
line port or fuel pump will not prime. (See illustration)

Air Adjustment:

The  oil  burner  on  this  machine  is  preset  for  opera-
tion at altitudes below 1000 feet. If operated at higher 
altitudes, it may be necessary to adjust the air band 
setting. Adjust air band for a #1 or #2  smoke spot on 
the Bacharach scale. A one-time initial correction for 
your  location  will  pay  off  in  economy,  performance, 
and extended service life. If a smoky or eye-burning 
exhaust  is  being  emitted  from  the  stack,  two  things 
should be checked. First, check the fuel to be certain 
that  kerosene  or  No.  1  home  heating  fuel  is  being 
used. Next, check the air adjustment on the burner. An 
oily, smoky fire indicates a lack of air and the air band 
should be moved to allow the air to flow through the 
burner. Sharp eye-burning fumes indicate too much air 
flowing through the combustion chamber. The air band 
should be readjusted to allow less air to flow through 
the burner.
To adjust: start machine and turn burner ON. Loosen 
two locking screws found in the air shutter openings 
(refer to illustration on page 8) and close air shutter 
until black smoke appears from burner exhaust vent. 
Note air band position. Next, slowly open the air shutter 
until white smoke just starts to appear. Turn air shutter 
halfway back to the black smoke position previously 
noted. Tighten locking screws.
If the desired position cannot be obtained using only 
the air shutter, lock the air shutter in as close a position 

as can be obtained, then repeat the above procedure 
on the air band setting.

Burner Nozzle:

Keep the tip free of surface deposits by wiping it with 
a clean, solvent-saturated cloth, being careful not to 
plug or enlarge the nozzle. For maximum efficiency, 
replace the nozzle each season.

Rupture Disk:

If pressure from pump or thermal expansion should 
exceed safe limits, the rupture disk will burst, allowing 
high pressure to be discharged through hose to ground. 
When disk ruptures it will need to be replaced.

Cleaning of Coils:

In alkaline water areas, lime deposits can accumulate 
rapidly inside the coil pipes. This growth is increased 
by the extreme heat build up in the coil. The best pre-
ventative  for  liming  conditions  is  to  use  high  quality 
cleaning detergents. In areas where alkaline water is an 
extreme problem, periodic use of Landa Deliming Pow-
der (Landa Part #9-028008) will remove lime and other 
deposits before coil becomes plugged. (See Deliming 
Instructions for use of Landa Deliming Powder.)

Deliming Coils:

Periodic flushing of coils is recommended.
Step 1  Fill the float tank with 4 gallons of water,  

 

then add 1 lb. of deliming powder. 

 

Mix thoroughly.

Step 2  Remove nozzle from the wand assembly  

 

and put the wand and spray gun into float  

 

tank.  Attach a nylon stocking to the end of  

 

the wand to collect debris.

Step 3  Turn pump switch on, allowing solution to be  

  pumped through coils and back into the float  
  tank. Solution should be allowed to circulate  
  2 - 4 hours.

Step 4  After circulating solution, clean and drain  

 

float tank and flush entire system with fresh  

 

water. Replace nozzle in wand.

Spray Nozzles:

Each machine is equipped with one spray nozzle. Dif-
ferent spray nozzles are calibrated for each machine 
depending on the flow and pressure of that particular 
model. Spray nozzles vary in bore size and angle of 
spray. Popular spray angles are 0°, 15°, 25°, 40°. When 
ordering,  please  specify  size  and  angle  of  nozzle. 
Nozzle size for each machine is located on the serial 
plate.

AIR BAND 

LOCKING SCREW

AIR SHUTTER 

LOCKING SCREW

AIR SHUTTER

AIR BAND

Содержание SEHW6-3500

Страница 1: ...8 913 932 0 OPERATOR S MANUAL For technical assistance or the Landa Dealer nearest you consult our web page at www landa com SEHW6 3500 SEHW 89139320 7 LISTED...

Страница 2: ...ion Important Safety Information 3 5 Component Identification 6 Assembly Instructions 7 Operation Instructions 8 Detergents General Cleaning Techniques 9 Shut Down Instructions 10 Storage 10 Troublesh...

Страница 3: ...fault circuit interrupter GFCI If rated more than 250 volts or more than single phase this product should only be connected to a power supply receptacle protected by a GFCI DANGER Improper connection...

Страница 4: ...s sibility of a fall due to slippery surfaces 20 Do not overreach or stand on unstable support Keep good footing and balance at all times 21 Do not operate this machine when fatigued or under the infl...

Страница 5: ...LANDA SEHW 8 913 932 0 Rev 02 12a 5 PRESSURE WASHER OPERATOR S MANUAL IMPORTANT SAFETY INFORMATION Follow the maintenance instructions specified in the manual...

Страница 6: ...vers a specific gpm to the high pressure nozzle which develops pressure Not Shown Spray Gun Controls the application of water and detergent onto cleaning surface with trigger device Includes safety la...

Страница 7: ...on ment Electrical connection to machine should be the proper voltage phase and amperage See specifications for particular model A power plug is not provided to ensure proper connection by an electric...

Страница 8: ...pressure switch which starts machine For auto start ma chines only When a steady stream of water flows from the spray gun and wand turn the thermostat knob to the 200 mark then push the burner switch...

Страница 9: ...rface at low pressure for best results limit your work area to sections approximately 6 feet square and always apply detergent from bottom to top Allow detergent to remain on surface 1 3 minutes Do no...

Страница 10: ...ssure washer in a location where the tempera ture will not fall below 32 F 0 C The pump in this machine is susceptible to permanent damage if frozen FREEZE DAMAGE IS NOT COVERED BY WARRANTY 1 Stop the...

Страница 11: ...fuel Improper fuel or water in fuel Drain fuel tank and fill with proper fuel Plugged fuel filter Replace as needed Misadjusted burner air bands Readjust air bands for clean burn Little or no fuel pr...

Страница 12: ...me build up in coils Clean inside of coils with coil clean Improper burner nozzle See parts list WATER TEMPERATURE TOO HOT Incoming water to machine warm or hot Lower incoming water temperature Fuel p...

Страница 13: ...tor tripped Push reset button Fuel pump seized Replace fuel pump Burner fan loose of misaligned Position correctly tighten set screw Defective control switch Replace switch Loose wire Check and replac...

Страница 14: ...r in valves Check and clean if necessary Worn bearings Check and replace if necessary PRESENCE OF WATER IN OIL Oil seal worn Check and replace if necessary High humidity in air Check and change oil tw...

Страница 15: ...ten under severe conditions OIL CHANGE RECORD MAINTENANCE SCHEDULE Pump Oil Inspect Oil level daily Change After first 50 hours then every 500 hours or annually Check and Tighten Belts Every 3 months...

Страница 16: ...visible through oil gauge window Oil should be maintained at that level Fuel Use clean fuel oil that is not contaminated with water and debris Use kerosene No 1 home heating fuel or diesel Drain fuel...

Страница 17: ...on cannot be obtained using only the air shutter lock the air shutter in as close a position as can be obtained then repeat the above procedure on the air band setting Burner Nozzle Keep the tip free...

Страница 18: ...ching the dis charge hose directly to the pump If high pressure is present then the unloader needs repairing CAUTION When using this procedure to test com ponents keep spray gun open at all times Remo...

Страница 19: ...ANUAL COIL REMOVAL INSTALLATION 89139320 3 Top Wrap 3 8 Screw Insulation Tabs Hold Down Bolt Insulation Retainer Plate 1 2 Pipe Nipple Thermostat Sensor Discharge Manifold Capillary Tube Rupture Disk...

Страница 20: ...ERATOR S MANUAL PRESSURE WASHER 20 EXPLODED VIEW LEFT SIDE 89139320 4 12 10 2 8 20 1 6 9 16 19 41 25 24 23 21 26 22 27 16 26 13 11 29 77 17 28 41 14 73 78 58 60 46 57 35 36 90 91 38 40 30 34 15 5 4 89...

Страница 21: ...GHT SIDE 89139320 5 To Control Panel Valve For Detail See Float Tank Illus For Detail See Control Panel Illus 50 56 50 85 51 76 17 80 94 67 49 44 52 47 42 43 83 82 79 28 17 81 64 62 68 3 3 69 28 17 32...

Страница 22: ...35 8 750 095 0 Thermostat 302 1 36 9 149 003 0 Discharge Manifold 1 ITEM PART NO DESCRIPTION QTY 37 8 716 547 0 Connector Straight 1 38 9 802 014 0 Nipple 1 2 x 3 Galvanized 2 39 9 802 797 0 Screw 10...

Страница 23: ...2 9 802 811 0 Washer 3 8 x 1 1 2 Fender SAE 8 83 9 802 067 0 Bumper Pad Engine 16 84 9 802 066 0 Pad Soft Rubber 50 Duro 8 85 8 716 547 0 Connector Straight 1 86 9 800 049 0 Label Manufacturer s Clean...

Страница 24: ...LANDA SEHW 8 913 932 0 Rev 02 12a OPERATOR S MANUAL PRESSURE WASHER 24 FLOAT TANK ASSEMBLY 89139320 6 11 17 3 15 24 16 2 20 7 13 14 4 5 8 1 12 19 6 9 10 To Pump Inlet 18 21 18 21 23 22 17 18...

Страница 25: ...2 Anchor 1 9 8 711 775 0 Inlet Hose 13 Supply Water 1 10 9 802 257 0 Inlet Hose 30 Supply Water 1 11 8 912 233 0 Lid and Hinges 1 12 9 802 185 0 Valve Float Tank Vertical 2 13 9 802 146 0 Swivel 1 2...

Страница 26: ...2 0 Rev 02 12a OPERATOR S MANUAL PRESSURE WASHER 26 CONTROL PANEL ASSEMBLY 89139320 8 32 16 21 15 27 17 24 26 20 19 18 22 23 33 12 31 5 30 2 1 5 6 4 9 10 14 13 38 39 3 28 29 8 11 25 35 36 37 40 7 6 29...

Страница 27: ...ormer Fuse See Specifications Pages 29 31 19 9 802 494 0 Bar Jumper 2 20 9 802 491 0 Block Strip Terminal 4 Pole 1 9 802 749 0 Screw 8 32 x 3 4 2 9 802 785 0 Nut 8 32 2 21 9 802 472 0 Timer Solid Stat...

Страница 28: ...L344 w Coupler w Soap Nozzle 1 83 SSVPKIT Repair Kit AR SS 1 3 8 751 234 0 Gun Landa L1050 5000 PSI 10 4 GPM 1 ITEM PART NO DESCRIPTION QTY 4 8 739 072 0 Hose 3 8 x 50 2 Wire Tuff Skin 1 5 9 802 166 0...

Страница 29: ...l Burner Fuel Pump Fuel Model No Assy No Nozzle Transformer Motor Solenoid Cord Solenoid Coil Electrode SEHW6 35024B 9 802 556 0 8 717 366 0 7 51824 9 803 056 0 7 21844U 7 21755U 8 740 110 0 SEHW6 350...

Страница 30: ...ulley Part Bushing Part Size Voltage PHHertz Part Pulley Part 6 35024B 5 5 LT6035 L 8 904 883 0 2BK60H 9 802 387 0 25mm 9 802 403 0 15 3 HP 230V 3PH 60 8 751 006 0 2TB40H 8 715 598 0 6 35024C 5 5 LT60...

Страница 31: ...Part Size Qty Part Contactor Overload Transformer Fuse Fuse Part Fuse Fuse Part 6 35024B P1x1 5 8 9 803 980 0 BX41 2 8 715 702 0 8 724 281 0 8 724 307 0 9 802 550 0 3 Amp 9 802 465 0 2 8 Amp 9 802 46...

Страница 32: ...g Tapered 2 31 9 803 148 0 Crankshaft GT4040 1 5030 1 6035 1 1 9 803 149 0 Crankshaft GT 4035 1 32 9 803 167 0 Crankshaft Key 1 33 9 802 923 0 Oil Dip Stick 1 34 9 803 139 0 Crankshaft Seal 1 35 9 803...

Страница 33: ...s G3 4 1 53 9 802 939 0 Cover Screw 5 Part available in kit See below REPAIR KIT NUMBER 8 916 488 0 8 916 487 0 8 916 322 0 8 916 323 0 9 802 607 0 9 802 611 0 KIT DESCRIPTION Plunger U Seal 20mm LT 4...

Страница 34: ...rt of the lock nut Item 19 If adjustment knob Item 18 DOES NOT make contact with upper nut Items 15 remove adjusting knob Item 18 re adjust raise nuts Items 15 on stem Item 8 and re attach adjustment...

Страница 35: ...using 1 18 12 16210000 M4 x 4mm Dowel 1 19 12 60170431 M22 Nut 1 20 12 14371900 Washer 9 x 15mm 1 ITEM PART NO DESCRIPTION QTY 21 12 60120861 Spring 3 x 33mm 1 22 12 60121031 Upper Frame 1 23 12 14742...

Страница 36: ......

Страница 37: ...ce center field labor charges or freight damage WHAT YOU MUST DO TO OBTAIN WARRANTY SERVICE While not required for warranty service we request that you register your LANDA pressure washer by returning...

Страница 38: ...Form 8 913 932 0 Revised 02 12a Printed in U S A...

Отзывы: