LANDA SEHW • 8.913-932.0 • Rev. 02/12a
OPERA
TOR’S MANU
AL
PRESSURE
W
ASHER
10
SHUTDOWN INSTRUCTIONS
STEP 1: Place detergent line in a
bucket of clear water allowing de-
tergent to be flushed from system.
Then turn detergent valve off.
STEP 3: Turn water off and remove
water supply hose.
STEP 2: Push burner switch off
and pull spray gun allowing water
to flow which will cool down the
heating coil.
After water has cooled, release the
trigger on the spray gun which will
activate a timer to shut the machine
off after one minute. Turn the pump
switch off if the machine is going to
be left unattended.
CAUTION: Always store your pressure
washer in a location where the tempera-
ture will not fall below 32°F (0°C). The
pump in this machine is susceptible to
permanent damage if frozen. FREEZE DAMAGE IS
NOT COVERED BY WARRANTY.
1. Stop the pressure washer, squeeze spray gun
trigger to release pressure.
2. Detach water supply hose and high pressure
hose.
3. Turn on the machine for a few seconds, until
remaining water exits. Turn engine off immediately.
4. Drain the gas and oil from the engine.
5. D o n o t a l l o w h i g h p r e s s u r e h o s e t o
become kinked.
6. Store the machine and accessories in a room which
does not reach freezing temperatures.
STORAGE
STEP 4: Open spray gun to relieve
remaining pressure.
Pump
Switch
Burner
Switch
Temp.
Control
Knob
After Extended Storage
CAUTION: Prior to restarting, thaw out any
possible ice from pressure washer hoses,
spray gun or wand.
Содержание SEHW6-3500
Страница 36: ......