manualshive.com logo in svg
background image

14

Troubleshooting

PROBLEM

POSSIBLE CAUSE

SOLUTION

PUMP RUNNING 

NORMALLY 

BUT PRESSURE 

LOW ON 

INSTALLATION

Pump sucking air

Check water supply and possibility of air.

Check valves sticking

Check and clean or replace if necessary.

Unloader valve seat faulty 

Check and replace if necessary.

Nozzle incorrectly sized

Check and replace if necessary.

Worn piston packing

Check and replace if necessary.

FLUCTUATING 

PRESSURE

Valves worn

Check and replace if necessary.

Blockage in valve

Check and clean if necessary.

Pump sucking air

Check water supply connections.

Worn piston packing

Check and replace if necessary.

Insufficient water

Check filter and hose for breakage.

PRESSURE LOW 

AFTER PERIOD 

OF NORMAL USE

Nozzle worn

Check and replace if necessary.

Suction or delivery valves worn

Check and replace if necessary.

Suction or delivery valves blocked Check and clean if necessary.
Unloader valve seat worn

Check and replace if necessary.

Unloader adjusted improperly

Call local Landa dealer. Tampering with the factory 
setting may cause personal injury and/or property 
damage and will void the manufacturer's warranty.

Worn piston packing 

Check and replace if necessary.

Bypass valve within unloader 
is obstructed or leaking

Remove and clean bypass cartridge.

PUMP 

NOISY

Air in suction line

Check water supply and connections on suction 
line.

Broken or weak suction 
or delivery valve spring

Check and replace if necessary.

Foreign matter in valves

Check and clean if necessary.

Worn bearings

Check and clean if necessary.

Excessive temperature of water

Reduce to below 140°F.

PRESENCE OF 

WATER IN 
PUMP OIL

Oil seal worn

Check and replace if necessary.

High humidity in air

Check and change oil twice as often.

Piston packing worn

Check and replace if necessary.

WATER DRIPPING 

FROM UNDER PUMP

Piston packing worn

Check and replace if necessary.

O-Ring plunger retainer worn

Check and replace if necessary.

OIL DRIPPING 

FROM PUMP

Oil seal worn

Check and replace if necessary.

EXCESSIVE 

VIBRATION IN HIGH 

PRESSURE HOSE

Irregular functioning of the pump 
valves

Check and replace if necessary.

Obstruction in filter

Clean inlet filter.

MOTOR WILL

NOT RUN

Motor overload

Push in the overload button located on the motor 
(single phase) or the overload button on the 
magnetic start switch (three phase).

Step down transformer fuses

Check fuses and voltage. Replace if necessary.

Coil of magnetic starter defective

Replace coil after the timer and unloader switch 
have been tested.

MACHINE WILL NOT 

TURN ON WHEN 

SWITCH IS PUSHED

Timer is defective

Join wires 15 and 16 together on timer. If machine 
works, replace timer.

Landa SEA  MS Operator’s Manual  9.801-720.0 - AJ

Содержание SEA 2.8/1000

Страница 1: ...lectric Powered Operator s Manual Pressure Washer MODELS SEA 2 8 1000 1 106 583 0 SEA 4 2 2000 A 1 106 584 0 SEA 4 2 2000 B 1 106 585 0 SEA 4 2 2000 C 1 106 586 0 SEA 4 2 2000 H 1 106 587 0 SEA 3 5 30...

Страница 2: ...2 Landa SEA MS Operator s Manual 9 801 720 0 AJ...

Страница 3: ...Detergents And General Operating Techniques 11 Thermal Pump Protection 11 Cleaning Tips 11 Shutting Down And Clean Up 12 Storage 13 Troubleshooting 14 Preventative Maintenance 15 Oil Change Record 15...

Страница 4: ...iarize the operator with the operation and function of the machine The MAINTENANCE section contains preventive main tenance to keep the machine and its components in good working condition They are li...

Страница 5: ...rator in the operator s native language by the purchaser owner making sure that the operator comprehends its contents Owner and or user must study and maintain for future reference the manufacturers i...

Страница 6: ...ment peut entra ner un risque d lec trocution V rifier aupr s d un lectricien qualifi ou du personnel d entretien si vous avez des doutes quant savoir si lasortie est correctement mise la masse NE PAS...

Страница 7: ...3 To keep machine in best operating conditions it is important you protect machine from freezing Failure to protect machine from freezing could cause malfunction of the machine and result in death ser...

Страница 8: ...n of water and detergent onto cleaning surface with trigger device Includes safety latch Wand Must be connected to the spray gun Swivel Connector Allows free range of movement to avoid coiling hoses N...

Страница 9: ...EP 3 Insert nozzle into coupler Release the coupler collar and push the nozzle until the collar clicks Pull the nozzle to make sure it is seated properly Landa SEA MS Operator s Manual 9 801 720 0 AJ...

Страница 10: ...G Never replace nozzles without engaging the safety latch on the spray gun trigger AVERTISSEMENT Ne jamais remplacer les buses sans d abord mettre le dispositif de s curit sur la d tente du pistolet p...

Страница 11: ...thermal device prevents internal damage to the pump Cleaning Tips Pre rinse cleaning surface with fresh water Place detergent suction tube directly into cleaning solution and apply to surface at low p...

Страница 12: ...ger to release water pressure STEP 7 Engage the spray gun safety lock Landa SEA MS Operator s Manual 9 801 720 0 AJ STEP 5 Disconnect the garden hose from the water inlet on the machine Protect from f...

Страница 13: ...r des dommages si elle est expos e au gel LES DOMMAGES DUS AU GEL NE SONT PAS COUVERTS PAR LA GARANTIE If you must store your pressure washer in a location where the temperature is below 32 F you can...

Страница 14: ...emove and clean bypass cartridge PUMP NOISY Air in suction line Check water supply and connections on suction line Broken or weak suction or delivery valve spring Check and replace if necessary Foreig...

Страница 15: ...life of your pressure washer Perform maintenance more often under severe conditions Oil Change Record Check pump oil level before first use Change pump oil after first 50 hours and every year or 500 h...