Safety

prise désignées du pistolet pulvérisateur et de la 
lance. Ne pas placer les mains ou les pieds sur des 
endroits non isolés de la laveuse à pression.

12. To reduce the risk of injury, close supervision is 

necessary when a machine is used near children. Do 
not allow children to operate the pressure washer. 
This machine must be attended during operation. 

WARNING: Grip cleaning wand 
securely with both hands before 
starting. Failure to do this could 
result in injury from a whipping 
wand.
AVERTISSEMENT: Agripper la lance 
de nettoyage avec les deux mains 
avant de commencer. Le non-
respect de cette consigne pourrait 
mener à des blessures causées par 

le mouvement violent de la lance.

13. Never make adjustments on machine while in opera-

tion.

14. Be certain all quick coupler fittings are secured before 

using pressure washer.

WARNING: High pressure developed 
by these machines will cause 
personal injury or equipment 
damage. Keep clear of nozzle. Use 
caution when operating. Do not 
direct discharge stream at people or 
animals, or severe injury or death 
will result. 

AVERTISSEMENT: La haute 
pression générée par ces machines 

causera des lésions corporelles ou des dommages à 
l'équipement. Se tenir à l'écart de la buse. Faire 
preuve de prudence lors de l'utilisation. Ne pas 
décharger directement le jet vers des personnes ou 
des animaux, car cela risquerait de causer des 
blessures graves ou même la mort.

WARNING: Protect machine from 
freezing.
AVERTISSEMENT: Protéger la 
machine contre le gel.

15. To keep machine in best operating 

conditions, it is important you 
protect machine from freezing. 
Failure to protect machine from 
freezing could cause malfunction 
of the machine and result in 

death, serious bodily injury, and/or property damage. 
Follow storage instructions specified in this manual.

16. Inlet water must be clean fresh water and no hotter 

then 90°F.

WARNING: Risk of asphyxiation. 
Use this product only in a well 
ventilated area. 
AVERTISSEMENT: Risque 
d'asphyxie. Utiliser ce produit 
uniquement dans un endroit bien 
ventilé.

17. Avoid installing machines in small 

areas or near exhaust fans. 
Adequate oxygen is needed for 

combustion or dangerous carbon monoxide will 
result.

18. Manufacturer will not be liable for any changes made 

to our standard machines or any components not 
purchased from us.

19. The best insurance against an accident is precaution 

and knowledge of the machine.

WARNING: Be extremely careful 
when using a ladder, scaffolding or 
any other relatively unstable 
location. The cleaning area should 
have adequate slopes and drainage 
to reduce the possibility of a fall 
due to slippery surfaces.
AVERTISSEMENT: Faire preuve 
d'une extrême prudence au 
moment d'utiliser une échelle, des 

échafaudages ou toute autre surface relativement 
instable. La zone de nettoyage doit avoir une pente et 
un drainage adéquats pour réduire la possibilité d'une 
chute due à une surface glissante.

20. Do not overreach or stand on unstable support. Keep 

good footing and balance at all times.

21. Do not operate this machine when fatigued or under 

the influence of alcohol, prescription medications, or 
drugs.

WARNING: Do not spray machine or 
any people, animals or electrical 
parts.

AVERTISSEMENT: Ne pas vaporiser 
sur la machine ou les gens, les 
animaux ou les pièces électriques

Follow the maintenance instructions 
specified in the manual. 

Landa HOT Series Operator’s Manual  8.917-208.0 - B

WARNING

TRIGGER GUN KICKS 

 BACK - HOLD WITH 

        BOTH HANDS

WARNING

RISK OF INJECTION 

OR SEVERE INJURY

TO PERSONS. KEEP 

CLEAR OF NOZZLE.

WARNING

PROCTECT FROM

FREEZING

WARNING

RISK OF 

ASPHYXIATION. 

USE THIS PRODUCT 

ONLY IN A WELL 

VENTILATED AREA.

WARNING

RISK OF INJURY

FROM FALLS WHEN

USING LADDER.

WARNING

DO NOT SPRAY 

MACHINE OR ANY 

PEOPLE, ANIMALS OR 

ELECTRICAL PARTS.

Содержание 1.109-093.0

Страница 1: ...Washer ELY RIA OHI O U S A MODELS HOT 2 11024D 1 109 095 0 HOT 2 15024D 1 109 096 0 HOT 2 11026D 1 109 093 0 HOT 2 15026D 1 109 094 0 HOT 3 11024D 1 109 097 0 HOT 3 30036D 1 109 100 0 HOT 4 20024A 1...

Страница 2: ...2 Landa HOT Series Operator s Manual 8 917 208 0 B Machine Data Label...

Страница 3: ...3 Thermal Pump Protection 13 Cleaning Tips 13 Rinsing 13 Shutting Down Clean up 14 Storage 14 Engine Maintenance 14 Maintenance Preventative Maintenance 15 Unloader Valves 15 Winterizing Procedure 15...

Страница 4: ...s When placing an order for parts the machine model and machine serial number are important Refer to the MACHINE DATA box which is filled out during the installation of your machine The MACHINE DATA b...

Страница 5: ...r with the controls 3 Stay alert watch what you are doing 4 All installations must comply with local codes Contact your electrician plumber utility company or the selling dealer for specific details I...

Страница 6: ...c or abrasive fluids to pass through the pump 9 Never run pump dry or leave spray gun closed longer than 1 2 minutes 10 Keep operating area clear of all persons and animals WARNING High pressure spray...

Страница 7: ...fied in this manual 16 Inlet water must be clean fresh water and no hotter then 90 F WARNING Risk of asphyxiation Use this product only in a well ventilated area AVERTISSEMENT Risque d asphyxie Utilis...

Страница 8: ...Detergent Pick up Tube Quick Coupler Power Supply GFCI Steam Nozzle Steam Wand 3 300 Spray Gun Trigger Variable Pressure Control Handle Variable Pressure Wand 2 11024D 2 15024D 3 11024D 4 2000 Pump S...

Страница 9: ...and a fan installed bringing the air into the machine WARNING Avoid small areas or areas near exhaust fans AVERTISSEMENT viter les petites superficies ou les surfaces proximit des ventilateurs d extr...

Страница 10: ...ar back If detergent is to be applied insert a detergent injector Insert quick coupler onto discharge nipple and secure by pushing quick coupler collar forward STEP 5 Release the coupler collar and pu...

Страница 11: ...g water to flush through the system until clear Turn pump switch ON or turn knob to pump position When a steady stream of water flows from the spray gun and wand the machine is ready for the high pres...

Страница 12: ...e must be inserted at end of wand to obtain high pressure Variable Pressure Wand Assembly Models using variable pressure wands grip spray gun securely Turn variable pressure control handle counter clo...

Страница 13: ...tion and apply to surface at low pressure for best results limit your work area to sections approximately 6 feet square and always apply detergent from bottom to top Allow detergent to remain on surfa...

Страница 14: ...s CAUTION Failure to follow the above directions will result in damage to your pressure washer ATTENTION Le non respect des directives ci dessus entra nera des dommages la laveuse pression When the pr...

Страница 15: ...tested at the factory before shipping Tampering with the factory setting may cause personal injury and or property damage and will void the manufacturer s warranty Winterizing Procedure Damage due to...

Страница 16: ...ustration Ignition Circuit Periodically inspect wires spring contact and elec trodes for condition security and proper spacing Transformer test CAUTION 10 000 VOLTS use defect free insulated screwdriv...

Страница 17: ...urn air shutter halfway back to the black smoke position previously noted Tighten locking screws If the desired position cannot be obtained using only the air shutter lock the air shutter in as close...

Страница 18: ...enance Schedule Pump Oil SAE 10W 40 non foaming Inspect Daily inspect the oil level Change After first 50 hours then every 500 hours or annually Clean Burner Filter Annually Remove Burner Soot From He...

Страница 19: ...on coils not allowing heat transfer Clean coils Lime deposits on inside of coil Delime coil WATER TEMPERATURE TOO HOT Defective high limit switch Replace Insufficient water supplied Check water G P M...

Страница 20: ...lves Check and clean if necessary Worn bearings Check and clean if necessary PRESENCES OF WATER IN OIL Oil seal worn Check and replace if necessary High humidity in air Check and change oil twice as o...

Страница 21: ...an as required Improper electrode setting Clean and test according to diagram in Operators Manual Fuel not reaching combustion chamber Check fuel pump for proper flow Check solenoid flow switch on mac...

Страница 22: ...8 917 208 0 Printed in U S A...

Отзывы: