Maintenance

Troubleshooting

PROBLEM

POSSIBLE CAUSE

SOLUTION

LOW OPERATING 
PRESSURE

Faulty pressure gauge

Install new gauge.

Insufficient water supply

Use larger garden hose; clean filter 
washer at water inlet.

Old, worn or incorrect spray nozzle

Match nozzle number to machine and/
or replace with new nozzle.

Plumbing or hose leak

Check plumbing system for leaks. Re-
tape leaks with teflon tape.

Faulty or mis-adjusted unloader valve 
(Where applicable)

Adjust unloader for proper pressure. 
Install repair kit when needed.

Worn packing in pump

Install new packing kit.

Fouled or dirty inlet or discharge
valves in pump

Clean inlet and discharge valves.

Worn inlet or discharge valves

Replace with valve kit.

LOW WATER 
TEMPERATURE

Soot buildup on coils not allowing heat 
transfer

Clean coils.

Lime deposits on inside of coil 

Delime coil.

WATER TEMPERATURE TOO 
HOT

Defective high limit switch 

Replace.

Insufficient water supplied 

Check water G.P.M. to machine.

Restricted water flow 

Check nozzle for proper size or obstruc-
tion.

DETERGENT NOT DRAWING

Air leak 

Tighten all clamps. Check detergent 
lines for holes.

Valve in the injector head may be 
blocked, dirty or damaged

Clean or replace valve in injector.

Filter screen on detergent suction 
hose plugged

Clean or replace.

Dried up detergent plugging metering 
valve

Disassemble and clean thoroughly.

High viscosity of detergent 

Dilute detergent to specifications.

Hole in detergent line(s) 

Repair hole.

Low detergent level 

Add detergent, if needed.

Variable pressure control handle set 
for high pressure

Turn variable pressure control handle to 
allow water to flow out of brass soap 
nozzle.

Landa HOT Series Operator’s Manual  8.917-208.0 - B

Содержание 1.109-093.0

Страница 1: ...Washer ELY RIA OHI O U S A MODELS HOT 2 11024D 1 109 095 0 HOT 2 15024D 1 109 096 0 HOT 2 11026D 1 109 093 0 HOT 2 15026D 1 109 094 0 HOT 3 11024D 1 109 097 0 HOT 3 30036D 1 109 100 0 HOT 4 20024A 1...

Страница 2: ...2 Landa HOT Series Operator s Manual 8 917 208 0 B Machine Data Label...

Страница 3: ...3 Thermal Pump Protection 13 Cleaning Tips 13 Rinsing 13 Shutting Down Clean up 14 Storage 14 Engine Maintenance 14 Maintenance Preventative Maintenance 15 Unloader Valves 15 Winterizing Procedure 15...

Страница 4: ...s When placing an order for parts the machine model and machine serial number are important Refer to the MACHINE DATA box which is filled out during the installation of your machine The MACHINE DATA b...

Страница 5: ...r with the controls 3 Stay alert watch what you are doing 4 All installations must comply with local codes Contact your electrician plumber utility company or the selling dealer for specific details I...

Страница 6: ...c or abrasive fluids to pass through the pump 9 Never run pump dry or leave spray gun closed longer than 1 2 minutes 10 Keep operating area clear of all persons and animals WARNING High pressure spray...

Страница 7: ...fied in this manual 16 Inlet water must be clean fresh water and no hotter then 90 F WARNING Risk of asphyxiation Use this product only in a well ventilated area AVERTISSEMENT Risque d asphyxie Utilis...

Страница 8: ...Detergent Pick up Tube Quick Coupler Power Supply GFCI Steam Nozzle Steam Wand 3 300 Spray Gun Trigger Variable Pressure Control Handle Variable Pressure Wand 2 11024D 2 15024D 3 11024D 4 2000 Pump S...

Страница 9: ...and a fan installed bringing the air into the machine WARNING Avoid small areas or areas near exhaust fans AVERTISSEMENT viter les petites superficies ou les surfaces proximit des ventilateurs d extr...

Страница 10: ...ar back If detergent is to be applied insert a detergent injector Insert quick coupler onto discharge nipple and secure by pushing quick coupler collar forward STEP 5 Release the coupler collar and pu...

Страница 11: ...g water to flush through the system until clear Turn pump switch ON or turn knob to pump position When a steady stream of water flows from the spray gun and wand the machine is ready for the high pres...

Страница 12: ...e must be inserted at end of wand to obtain high pressure Variable Pressure Wand Assembly Models using variable pressure wands grip spray gun securely Turn variable pressure control handle counter clo...

Страница 13: ...tion and apply to surface at low pressure for best results limit your work area to sections approximately 6 feet square and always apply detergent from bottom to top Allow detergent to remain on surfa...

Страница 14: ...s CAUTION Failure to follow the above directions will result in damage to your pressure washer ATTENTION Le non respect des directives ci dessus entra nera des dommages la laveuse pression When the pr...

Страница 15: ...tested at the factory before shipping Tampering with the factory setting may cause personal injury and or property damage and will void the manufacturer s warranty Winterizing Procedure Damage due to...

Страница 16: ...ustration Ignition Circuit Periodically inspect wires spring contact and elec trodes for condition security and proper spacing Transformer test CAUTION 10 000 VOLTS use defect free insulated screwdriv...

Страница 17: ...urn air shutter halfway back to the black smoke position previously noted Tighten locking screws If the desired position cannot be obtained using only the air shutter lock the air shutter in as close...

Страница 18: ...enance Schedule Pump Oil SAE 10W 40 non foaming Inspect Daily inspect the oil level Change After first 50 hours then every 500 hours or annually Clean Burner Filter Annually Remove Burner Soot From He...

Страница 19: ...on coils not allowing heat transfer Clean coils Lime deposits on inside of coil Delime coil WATER TEMPERATURE TOO HOT Defective high limit switch Replace Insufficient water supplied Check water G P M...

Страница 20: ...lves Check and clean if necessary Worn bearings Check and clean if necessary PRESENCES OF WATER IN OIL Oil seal worn Check and replace if necessary High humidity in air Check and change oil twice as o...

Страница 21: ...an as required Improper electrode setting Clean and test according to diagram in Operators Manual Fuel not reaching combustion chamber Check fuel pump for proper flow Check solenoid flow switch on mac...

Страница 22: ...8 917 208 0 Printed in U S A...

Отзывы: