![LANCIER Monitoring ACS 5000 Скачать руководство пользователя страница 10](http://html1.mh-extra.com/html/lancier-monitoring/acs-5000/acs-5000_operating-instructions-manual_3471547010.webp)
Page 10
Mounting
Wall Mounting
The ACS is designed for wall mounting.
The housing contains four drilled holes (
2
)
for this purpose.
The place of mounting should be dry and
swept clean.
• Drill four 6 mm holes in a wall strong
enough to support the device.
The holes should be
148 mm apart horizontally and
88 mm apart vertically
• Open the housing cover by removing its four screws (
3
).
• Mount the device on a wall using the screws and wall anchors provided.
• Make sure the device is attached to the wall with the wire connectors facing
upwards.
• Fasten the four screws (
2
) tightly in the wall in such a way that there is no
play.
ACS
Unit
Содержание ACS 5000