(9) Wearing sanitary gloves, carefully press the diffuser into the mounting area on the
underside
of
the
valve.
(10) Make certain the nozzle o-ring, is in place around the nozzle mounting area on the
valve. If necessary, slide a new nozzle o-ring onto the nozzle mounting area.
(Wear sanitary gloves while handling the o-ring.)
(11) Wearing sanitary gloves, install the nozzle by inserting it into the bottom plate and
twisting it clockwise to lock it in place.
(12) Connect power and replace cover. Valve is ready for operation.
(13) Draw drinks to flush residual sanitizing solution. Taste the beverage to verify that
there is no off taste. If an off taste is found, additional flushing may be required.
3. Valve and System Sanitizing
a. The complete valve and dispenser system must be sanitized during initial installation.
Follow the manufacturer’s instructions when scheduling and conducting dispenser
sanitizing. The valve must be sanitized once every two weeks. The valve may remain
on the dispensing tower during the sanitizing process.
b. For syrup side line priming, and cleaning and sanitization procedures, refer to the
Syrup Purge Plug (Lancer PN 52-1912) in Section 2.5.C.
C. Syrup Purge Plug (See Figure 3)
1. The Syrup Purge Plug (PN 52-1912), places the valve in continuous syrup side operation.
The targeted uses for the purge plug consist of priming the syrup line on an initial
Volumetric Valve install, and for cleaning and sanitization of the syrup side of the
dispensing
unit.
2. Operation of the syrup purge plug is as follows:
NOTE:
With a standard 75 VA transformer, up to six
(6) Volumetric Valves can be operated in the
syrup purge mode simultaneously.
a. Turn off electrical power to all valves.
b. Install syrup purge plugs into the valve or
valves to be primed or sanitized. The
syrup purge plug installs in the ten-pin
connector of the Volumetric Valve circuit
board.
c. Turn on electrical power to the valves. At this time, the syrup side of the valves will
begin
continuous
operation.
d. When through with the priming or sanitization operation, syrup purge operation can be
stopped either of two ways:
Method 1:
Turn off electrical power to all valves, remove syrup purge plugs from the
valves. Turn on electrical power to all valves. Tap valve lever or push button to ensure
proper operation of all valves.
Method 2:
Remove syrup purge plug from the valves while they are in purge operation.
In this case, the valve may continue in the purge mode for up to six (6) seconds after
removal of the plug (this is normal). Tap valve lever or push button to ensure proper
operation
of
all
valves.
Syrup Purge Plug, Volumetric Valve
Figure 3
52-1912
SYRUP PURGE
17