![lancer Flavor Select 30 Скачать руководство пользователя страница 8](http://html2.mh-extra.com/html/lancer/flavor-select-30/flavor-select-30_operation-manual_3499696008.webp)
8
Dispenser Installation
1.
Remove the cup rest, drip tray, splash plate, merchandiser,
and top cover from the unit.
2.
Remove the cover plate at the back of the unit (if not a
through-the-counter installation).
3.
Route appropriate tubing from the plain water supply line
and the water supply for the carbonator and connect tubing
to 3/8 inch barb inlets at the front of the unit using the oetiker
pliers and fittings.
DO NOT PLUG UNIT INTO GROUNDED ELECTRICAL
OUTLET AT THIS TIME.
Make sure that all water lines
are tight and unit is dry before making any electrical
connections
!
WARNING
Drain line must be insulated with a closed cell
insulation. Insulation must cover the entire length of
the drain hose, including fittings. The drain should be
installed in such a manner that water does not collect
in sags or other low points, as condensation will form.
!
CAUTION
A
B
C
A. CO
2
Inlet
B. Fitting
C. Tubing
9. Route drain hose from designated open type drain to fitting
on Drip Tray and connect hose to fitting.
Pouring hot water into drain may cause the Drain
Tube to collapse. Allow only luke warm or cold water
to enter Drain Tube.
Pouring coffee tea and similar
substances into drain may cause the Drain Tube to
become clogged with coffee or tea grounds, or other
solid particles.
!
ATTENTION
A
B
C
A. Oetiker Pliers
B. Fitting
C. Tubing
D. Syrup/Water
Inlet
D
A
A. Drain Fitting
B. Drain Line
C. Drip Tray
B
C
See Plumbing Diagrams on the front of the unit or on
pages 26 - 27 for reference.
NOTE
4.
Connect tubing to water source then flush water lines to
check for leaks.
5. Route appropriate tubing from the remote pump deck to the
carbonated water inlet and connect tubing to inlet.
6.
Route appropriate tubing from the syrup pump location to the
syrup inlets at front of the unit and connect tubing to inlets.
7.
Repeat Step 5 for flavor injector lines.
8.
Route appropriate tubing from the CO
2
source location to the
CO
2
inlet on the unit and connect tubing to inlet.
10.
Reattach Drip Tray/Cup Rest to unit.
11.
Route the power supply cord to a grounded electrical outlet
of the proper voltage and amperage rating.