![lancer Flavor Select 30 Скачать руководство пользователя страница 14](http://html2.mh-extra.com/html/lancer/flavor-select-30/flavor-select-30_operation-manual_3499696014.webp)
14
Ice Bin Cleaning - Start-Up and Monthly
1.
Disconnect power to the dispenser
2.
Remove Top Cover.
3.
Melt out any remaining ice from the bin.
4.
Remove Agitator Pin from Agitator Shaft. Slide Agitator Shaft
rearward out of the motor shaft and pull out of rear bearing
to remove.
5. Remove the dispensing wheel from the motor shaft by sliding
rearward.
Refer to the Automatic Agitation Warning on page 4.
NOTE
Steps 6-7 highlight how to remove a white pellet ice
wheel shroud. If the unit uses a black cubed ice wheel
shroud, skip to step 8.
NOTE
9. Remove the lower ice chute assembly.
10. Use the Cleaning Solution, and a clean cloth or soft brush,
to clean all removable parts, sides of the Ice Bin, Auger, and
surface of the aluminum casting.
11. Using the Cleaning Solution and the sponge brush provided,
clean all interior surfaces of the ice chute and the ice chute
feed through.
12.
Repeat Step 6 for all exterior surfaces of the dispenser.
13.
Using hot water, thoroughly rinse away the cleaning solution.
14.
Wearing sanitary gloves, soak a clean cloth towel in
Sanitizing Solution and wash all surfaces of removable parts,
sides of the Ice Bin, Auger, and surface of the aluminum
casting.
15.
Using the Sanitizing Solution and the sponge brush
provided, clean all interior surfaces of the ice chute and the
ice chute feed through.
16.
Repeat Step 10 for all exterior surfaces of the dispenser.
17.
Wearing sanitary gloves, reassemble all removable parts.
Ensure agitator clip is locked.
18.
Fill Unit with ice and replace Top Cover.
19. Reconnect Dispenser to power source.
Daily Cleaning
1. Carefully remove the nozzle housings by turning
counterclockwise and pulling down from the nozzle
body.
2.
Wash the nozzle housings in cleaning solution and
rinse with clean warm water.
3.
Wet a clean cloth in cleaning solution.
4.
While the nozzle housing is removed, wipe down the
perimeter and end of the nozzle body.
5. Fill a cup with clean warm water and rinse nozzle
body.
6.
Make certain that the nozzle o-ring is not torn or
otherwise damaged. If necessary, replace damaged
o-ring with Lancer PN 02-0231.
7.
Wet the inner surface of the nozzle housing with water
and reinstall the nozzle housing by sliding it over the
nozzle body and turning clockwise to lock in position.
6.
Remove the gasket which secures the shroud by pulling it
out, (See page XX for reference).
7.
Push the front section of the wheel shroud back, then pull
the shroud up and out to remove.
8.
Remove the dispensing wheel shroud assembly.