TROUBLE
CAUSE
REMEDY
Noisy/cavitating carbonator
pump.
1.
Insufficient incoming water supply pressure.
1.
Verify incoming supply water pressure to
carbonator pump is min. of 25 PSI (0.172
MPA), max. of 50 PSI (0.345 MPA).
Circuit breaker tripping.
1.
Valve wire harnesses shorted to itself or
faucet plate.
2.
Controller PCB is bad.
3.
Secondary wire harness is shorted.
4.
Power supply is bad.
1. Detect short by disconnecting valve har-
nesses from switch panel (2 25-pin harness
-
es and 2 9-pin harnesses). Restore power. If
breaker does not trip, then find and replace
shorted harness. If breaker still trips, reinstall
the eight harnesses and proceed to Step 2.
2.
Detect by disconnecting the white 5-pin
harness from the controller PCB. Restore
power. If breaker does not trip, then replace
controller PCB. If breaker still trips, reinstall
the white 5-pin harness and proceed to Step
3.
3. Locate short from a motor or solenoid
harness and replace as necessary.
4. Detect short by disconnecting all harnesses
connected to power supply. Restore power.
If breaker still trips, replace power supply.
TROUBLE
CAUSE
REMEDY
BIB pump does not operate
when dispensing valve is
opened.
1. Out of CO
2
, CO
2
not turned on, or low CO
2
pressure.
2. Out of syrup.
3.
BIB connector not tight.
4. Kinks in syrup or gas lines.
1.
Replace CO
2
supply, turn on CO
2
supply, or
adjust CO
2
pressure to 70-80 PSI (0.483-
0.552 MPA).
2.
Replace syrup supply.
3. Fasten connector tightly.
4. Straighten or replace lines.
BIB pump operating, but no
flow.
1. Leak in syrup inlet or outlet line.
2.
Defective BIB pump.
1.
Replace line.
2.
Replace BIB pump.
BIB pump continues to oper
-
ate when bag is empty.
1. Leak in suction line.
2.
Leaking o-ring on pump inlet fitting.
3.
Defective syrup BIB pump.
1.
Check BIB connector, if still leaking then
replace line.
2.
Replace o-ring
3.
Replace defective pump.
BIB pump fails to restart after
bag replacement.
1.
BIB connector not on tightly.
2.
BIB connector is stopped up.
3. Kinks in syrup line.
1.
Tighten BIB connector.
2.
Clean out or replace BIB connector.
3. Straighten or replace line.
BIB pump fails to stop when
dispensing valve is closed.
1.
Leak in discharge line or fittings.
2.
Empty BIB.
3. Air leak on inlet line or bag connector.
1.
Repair or replace discharge line.
2.
Replace BIB.
3.
Repair or replace.
Remote Syrup/Flavor Shot Pump Troubleshooting