7.1  REFRIGERATION DECK ASSEMBLY (CONTINUED) 

ITEM   PART NO.  DESCRIPTION

  -  

82-2554 

Deck Assy, Refrigeration,  

 

 115V/60Hz

  -  

82-2486 

Deck Assy, Refrigeration,  

 

 230V/50Hz

  -  

82-2633 

Deck Assy, Refrigeration,  

 

 220V/60Hz

  1  

51-5107/01  Deck Plate, Sub-Assy

  2  

50-0200/01  Insulation, Deck Plate

  3  

04-0063 

Washer, Flat, 1/4”

  4  

89-0014

 

Hole Cover

  5  

82-2494 

Evaporator Assy

  6  

52-1773 

Probe Assy

  7  

04-0394 

Screw, 6 - 32 X .

500

  8  

51-0068 

Handle

  9  

04-0574 

Washer, Lock, 5/16”

  10  

REF 

Control Housing Assy

  -  

52-0900/02  Control Housing Assy with Kill    

 Switch 

  -  

52-0903/02  Control Housing Assy without Kill  

 Switch

  11  

06-2221 

Label, Wiring Diagram

  12  

04-0504 

Screw, 8 - 18 X .375”

  13  

06-0080/01  Label, Nameplate 

  14  

52-1209 

Lead Assy, Ground 

  15  

02-0041 

Seal

  16  

25-0047

 

Transformer, 75VA, 24V,  

 

 115V/60Hz

  -  

25-0048 

Transformer, 75VA, 24V,  

 

 220V/50-60Hz

  17  

82-2558 

Agitator Assy, 115V/60Hz

  -  

82-2487 

Agitator Assy, 230V/50Hz

  -  

82-2761 

Agitator Assy, 220V/60Hz

  17a  

05-0424/01

  Propeller, 2.625” Diameter

  17b  

91-0119

 

Motor, Agitator, 115V/60Hz

  -  

91-0112

 

Motor, Agitator, 230V/50Hz

  -  

91-0130

 

Motor, Agitator, 220V/60Hz

  17c   06-0633 

Label, 115V/60Hz, 25W

  -  

06-0634 

Label, 230V/50Hz, 25W

  -  

06-2191 

Label, 220V/60Hz, 25W

  17d   04-0059 

Screw, 8 - 36 X .375” 

  17e  

30-5113/01

  Bracket, Agitator Motor

  17f   02-0032 

Washer, Rubber

  17g   05-1437 

Propeller, Water

  18  

02-0040 

Seal, Extrusion

  19  

04-0032 

Nut, Lock, 1/4” - 20

  20  

83-0033 

Compressor Assy, 1/3 hp,  

 

 

115V/60Hz (includes items listed  

 below)

  -  

83-0034 

Compressor Assy, 1/3 hp,  

 

 240-220V/50Hz 

  -  

83-0038

 

Compressor Assy, 1/3 hp,  

 

 220V/60Hz

  20a   83-0033-01  Compressor, 1/3 hp, 115V/60Hz

  -  

83-0034-01  Compressor, 1/3 hp,    

 

 240-220V/50Hz

  20b   04-1010 

Screw, Brass, 6 - 32 X 0.250” 

  20c  

12-0339

 

Overload, 115V, 60Hz

  -  

12-0290

 

Overload, 230V, 50Hz

  -  

12-0253

 

Overload, 220V, 60Hz

  20d  

12-0005

 

Relay, 115V, 60Hz

  -  

12-0031

 

Relay, 230V, 50Hz

  -  

12-0028

 

Relay, 220V, 60Hz

  20e   13-0066 

Cover, Terminal

  20f   03-0040 

Bale Strap

ITEM   PART NO.  DESCRIPTION

  20g   03-0041  

Spring Overload (Not Shown)

  20h  

12-0260

  

Start Capaciter, 220V/60Hz (Not  

 Shown)

  21  

02-0114

  

Grommet, Compressor

  22  

04-0537  

Washer, Compressor

  23  

03-0150

  

Clip, Retainer, Compressor

  24  

47-0344

  

Tube, Process

  25  

47-0718  

Tube, Compressor Discharge

  26  

47-0724  

Tube, Return Line

  27  

51-0061

  

Accumulator

  28  

50-0211  

Boot

 

29

  

50-0205  

Insulation

  30  

50-0159  

Insulation

  31  

23-0985

  

Condenser

  32  

50-0201 

Baffle, Rubber

  33 

30-5112 

Retainer Strip

  34 

040518 

Rivet, 0.125” X 0.328”

  35 

30-5867 

Handle/Air Shield

  36 

30-5865 

Fan Shroud, Upper

  37 

50-0249 

Insulation, Strip

  38 

30-5866 

Fan Shroud, Lower

  39 

52-2140 

Fan Assy, 115V/60Hz 

  - 

52-2147 

Fan Assy, 220V/50-60Hz

  39a 

91-0007

 

Motor Assy, 115V/60Hz, 9W

   

91-0009 

Motor Assy, 220V/50-60Hz, 9W

  39b  

07-0354

  

Fan Blade

  39c  

04-0060

  

Nut, Flat

  39d  

30-5864

  

Bracket, Fan Motor

  39e   02-0033  

Silencer, Fan Blade

  39f   04-0059  

Screw, 8 - 36 X 0.375”

  39g   06-0433/01   Label, 115V/60Hz, 9W

  -  

06-0670  

Label, 220V/50-60Hz, 9W

  40  

23-0765  

Dryer Cap Assy

  40a  

23-0982

  

Dryer Cap

  40b  

47-0344

  

Tube, Process

  40c   47-0698  

Tube, Condenser, Out

  41  

52-2008  

Harness Assembly, Transformer

  42  

04-0110  

Nut, 8-32

  43  

04-0576  

Washer, Lock, Internal Tooth

  44  

06-0430  

Label, 115V/60Hz, 1/3 HP

  -  

06-0460  

Label, 230V/50Hz, 1/3 HP

  -  

06-0666  

Label, 240V/60Hz, 1/3 HP

  45  

06-0877  

Label, Ground

  -  

11-0018  

Wire Tie

  -  

15-0012

  

Duct Tape

  -  

15-0011  

Adhesive, Insulation

  -  

95-0177  

Refrigerant, R-134a

  -  

96-0004  

Solder, 60/40

  -  

96-0003  

Brazing Alloy

  -  

26-0377  

Capacitor, 230V/50Hz (For use  

 

with PN 

91-0065

)

  -  

26-0374  

Capacitor, 115V/60Hz (For use   

 

with PN 

91-0063

)

Содержание DELTA III 9100 Series

Страница 1: ...anty 800 729 1550 custserv lancercorp com lancercorp com Manual PN 28 0447 MAY 2000 FOR QUALIFIED INSTALLER ONLY DELTA III REMOTE RECIRCULATING UNIT LANCER SERIES 9100 Operation Manual PN 28 0447 Lanc...

Страница 2: ...ON BETWEEN TOWER AND PYTHON 6 2 SCHEDULED MAINTENANCE 6 2 1 DAILY 6 2 2 WEEKLY 6 2 3 MONTHLY 6 2 4 EVERY SIX MONTHS 7 2 5 YEARLY 7 3 DISPENSER CLEANING AND SANITIZING 7 3 1 AMBIENT PROCESS 7 3 2 ALTER...

Страница 3: ...IS FROZEN 13 6 19 COMPRESSOR CYCLES ON AND OFF FREQUENTLY DURING THE INITIAL PULLDOWN AND OR NORMAL OPERATIONS 13 6 20 CIRCUIT BREAKER POPPING 13 6 21 BIB PUMP DOES NOT OPERATE WHEN DISPENSING VALVE I...

Страница 4: ...6 2 kg Operating 237 pounds 108 kg ICE Capacity 25 28 lbs 11 3 to 12 7 kg FITTINGS Water for carbonator inlet 3 8 barb Plain water inlet 3 8 barb Brand syrup inlets 3 8 barb CO2 inlet 3 8 barb CARBONA...

Страница 5: ...nt Once power is restored the five 5 minute compressor delay would be in effect 6 Supply Water Pressure Minimum 25 PSIG 1 76 kg cm2 Maximum 50 PSIG 3 5 kg cm2 If pres sure is over 50 PSIG a water pres...

Страница 6: ...ACKING INSTALLATION KITS A Inspect kits for concealed damage and if evident notify delivering carrier and file a claim against same B Each kit contains a list of the parts and a drawing showing the pr...

Страница 7: ...hon must not exceed 25 feet 8 meters if built in syrup pumps are being used C Position one end of python near remote unit Slit the python insulation back 18 inches 45 cm from end and roll insulation b...

Страница 8: ...FIGURE 1 CONNECTING PYTHON TO REMOTE RECIRCULATING UNIT STANDARD PUMP SHOWN FIGURE 2 CONNECTING PYTHON TO DELTA TOWER 3...

Страница 9: ...ect extension cord to white and black wires C Route extension cord with python to tower D Connect white wire to terminal on key lock switch and black wire to loose black wire in tower E A separate pow...

Страница 10: ...e unit through hole in counter to the BIB syrup supply D Dip hose connectors in a cup of warm potable water E Attach the BIB hose connectors to the appropriate syrup flavor 1 14 CONNECTING TO REMOTE B...

Страница 11: ...ly 18 inches from the end of the python insulation C Starting as close to the remote unit as possible wrap the syrup soda and plain water lines with a single layer of insulated tape until all plastic...

Страница 12: ...chlorine solution containing at least 50 PPM 50 mg L available chlorine Make sure that lines are completely filled and allow to stand for 10 minutes G Reconnect syrup containers and ready Unit for op...

Страница 13: ...t tubes and elbow It will be necessary to cut the securing Oetiker clamps 5 2 INSTALLING REMOTE PUMP OR SYRUP TANKS A Install new 1 4 inch male flare CO2 carbonator check valve B Connect the CO2 suppl...

Страница 14: ...il and switch Replace if necessary B Remove valve from mounting block and open shutoffs slightly and check water and syrup supply If no supply check dispenser for freeze up or other problems C Reset t...

Страница 15: ...the unit OFF and then ON by using the ON OFF switch on top of the unit or by unplug ging unit momentarily C Check connections of liquid level probe to PCB assembly D Replace PCB assembly E Replace liq...

Страница 16: ...rough grill B Switch to cold water supply C Refer to Items 6 16 through 6 20 D Repair and recharge E Replace condenser fan motor F Clean condenser G Add pre cooler or replace with larger dispenser 6 1...

Страница 17: ...compressor or deck 6 16 Compressor starts but does not switch off start winding will run for only a few seconds before internal overload switches compressor off A Inadequate voltage B Incorrect wiring...

Страница 18: ...from PCB Restore power if breaker doesn t trip Then replace PCB If breaker does trip then PCB is OK Reconnect J1 connector C If it does not pop locate short in secondary harness between trans former P...

Страница 19: ...C Air leak on inlet line or bag connector A Repair or replace discharge line B Replace BIB C Repair or replace 6 26 Low or no carbonation A Low or no CO2 B Excessive water pressure C Worn or defectiv...

Страница 20: ...SEMBLY LOA D LIN E 33 34 32 36 35 31 34 33 32 12 38 12 40C 39 39A 39B 39C 12 39G 39D 39F 39E 40B 40A 3 2 3 4 19 6 7 5 45 1 9 15 12 11 10 41 12 16 18 8 48 42 43 14 17 17A 17B 17C 17F 17G 17E 17D 13 37...

Страница 21: ...04 1010 Screw Brass 6 32 X 0 250 20c 12 0339 Overload 115V 60Hz 12 0290 Overload 230V 50Hz 12 0253 Overload 220V 60Hz 20d 12 0005 Relay 115V 60Hz 12 0031 Relay 230V 50Hz 12 0028 Relay 220V 60Hz 20e 1...

Страница 22: ...17 7 2 CABINET ASSEMBLY TO TOWER HIGH CAPACITY OPTION 1 5 21 3 16 2 30 9 15 23 22 6 6 7 11 14 18 20 29 28 27 24 26 33 37 36 35 38 32 31 34 4 6 19 21 17 10 13 12 26 25 8...

Страница 23: ...el Overflow 19 50 0248 Insulation Tank Front 20 08 0004 Tubing Tygon 5 16 ID 21 50 0151 Insulation Tank Sides 22 51 0717 01 Bracket Leg 23 81 0112 Leg Plastic 24 82 0795 Pump Recirculation 115V 82 079...

Страница 24: ...ILL HOLE IMPORTA NT FILL WATER BATH UNTIL TA NK OVERFLOW TUBE WATER FLOWS FROM TO COMPRESSOR DECK 10 13 12 16 9 8 7 32 11 37 20 20 36 21 22 35 35 28 33 23 25 24 26 27 34 23 19 17 29 30 18 3 14 1 2 6 1...

Страница 25: ...er Fill 16 01 1515 Pump Outlet Assy 82 0900 Pump Bracket Assy 6 Pump 82 0906 Pump Bracket Assy 5 Pump 17 30 5111 Pump Support 18 04 0504 Screw 8 18 X 0 375 19 82 0251 Mini Pump 20 04 0275 Screw Half M...

Страница 26: ...ES SYRUP CO2 WATER ASSEMBLIES TO PYTHON BAG IN BOX CONFIGURATION FIGAL REMOTE CONFIGURATION 34 30 29 28 27 26 34 34 17 18 20 7 6 21 20 6 19 8 5 34 34 36 25 33 2 38 17 3 22 16 15 14 23 34 13 12 11 4 5...

Страница 27: ...rup use on 6 valve units 27 REF Tube Assy Syrup No 4 48 0476 01 Tube Assy Syrup Figal Remote Use on 6 Valve Units 48 0477 01 Tube Assy Syrup Figal Remote Use on 5 Valve Units 48 0478 01 Tube Assy Syru...

Страница 28: ...Assy Probe Ground Non Carb Units Only 6 52 2061 Lead Assy EIBC 7 12 0190 Terminal Block 8 04 0477 Screw 8 32 X 0 375 9 04 0504 Screw 8 16 X 0 375 10 30 5108 01 Cover Control Box ITEM PART NO DESCRIPT...

Страница 29: ...DESCRIPTION 18 0253 02 Regulator Assembly Water 1 05 0017 Washer Seal Flare Nylon 2 49 0227 Hose Regulator Assy 3 18 0252 Regulator 4 01 0446 Fitting Barb 5 07 0481 Bracket Regulator 6 04 0504 Screw 8...

Страница 30: ...nly S5 S6 S3 S4 S1 S2 W W W W B B B B W B B W B B 24 V LINE TB1 W ELECTRONIC ICE BANK PROBE B 9000 and 9100 Series Only B CARBONATOR MOTOR CAPACITOR CARBONATOR MOTOR RIBBED BLK FAN MOTOR B W G W B 3 G...

Страница 31: ...26 NOTES...

Страница 32: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Отзывы: