9
Installing CO
2
Supply
Before installing regulator, assure that a seal (washer
or o-ring) is present in regulator attachment nut.
!
ATTENTION
A. CO
2
Regulator
B. Wrench
C. 1/4” nut, Stem
D. CO
2
Supply
A
B
C
D
-
Thread regulator nut on to tank,
then tighten nut with wrench
A. CO
2
Regulator
B. Outlet
C. Wrench
D. CO
2
Supply
A
B
C
D
1. Connect high pressure CO
2
regulator assembly to CO
2
cylinder or bulk system.
2. Connect a 1/4” nut, stem and seal to CO
2
regulator outlet.
Then connect tubing routed from tee at syrup pumps tanks.
A. CO
2
Regulator
B. Fitting
C. Line to CO
2
Regulator
Manifold
D. Oetiker Pliers
A
B
C
D
3. Using a wrench, loosen lock nut on regulator adjustment
screw then using a screwdriver back out lock nut screw all
the way.
A. CO
2
Regulator
B. Screwdriver
C. Regulator Adjustment Screw
A
B
C
4. Turn on CO
2
and using a screwdriver, adjust regulator to 75
PSI (0.517 MPA) then tighten lock nut with wrench.
A. Regulator Adjustment Screw
B. Adjust to 75 PSI (0.517 MPA)
C. Wrench
A
B
C