background image

8

 

Drain line must be insulated with a closed cell 

 

insulation. Insulation must cover the entire length of 

the drain hose, including fittings. The drain should be 

installed in such a manner that water does not collect 

in sags or other low points, as condensation will form.

CAUTION

 

Pouring hot water into drain may cause the Drain Tube 

 

to collapse. Allow only luke warm or cold water to enter 

 

Drain Tube.

 

Pouring coffee tea and similar substances 

 

into drain may cause the Drain Tube to become 

 

clogged with coffee or tea grounds, or other solid 

 particles.

ATTENTION

16.  Re-install cup rest and splash plate.
17.  Turn on water supply and check for leaks.  
18.  Plug power cord into designated grounded electrical outlet.

 

The dispenser must be properly electrically ground-

ed to avoid serious injury or fatal electrical shock. 

The power cord has a three-prong grounded plug. If a  

three-hole grounded electrical outlet is not available, 

use an approved method to ground the unit. Follow 

all local electrical codes when making connections. 

Each dispenser must have a separate electrical circuit. 

Do not use extension cords. Do not connect multiple   

electrical devices on the same outlet.

WARNING

19.  Turn on the power switch, at the top of the unit, to turn on 

the unit and begin building an ice bank.

Installing Remote Syrup Pumps - Bag in Box

A

B

C

A. Syrup Pump

B. CO2 Line

C. Fitting

D. Oetiker Pliers

D

1.  Install BIB rack and remote pumps according to            

manufacturers’ instructions.

2.  Once pumps and BIB rack are installed, measure and cut 

tubing to length between the pump CO

2

 inlets, then connect 

tubing to all pumps.

3.  Using tubing cutters, cut any pump CO

2

 supply line and 

install tee fitting, then route appropriate tubing from the CO

2

 

supply to the tee fitting at syrup pumps. 

A

B

C

A. Syrup Pump Outlet

B. Syrup Pump

C. Fitting

4.  Connect tubing from dispenser syrup inlet to the syrup 

pump outlet fitting. Repeat for each syrup line/pump. 

 

Use proper connector for syrup manufacturer

ATTENTION

A. Syrup Pump Inlet     C. BIB Connector

B. Fitting  

        D. Oetiker Pliers

A

B

C

D

A. Tee Fitting

B. Line to Syrup Pump

C. Fitting

D. Line to CO

2

 Supply

A

B

B

C

D

5.  Install BIB (bag in box) connectors onto the syrup pump 

inlet tubing.

6.  Connect syrup BIBs to connectors. Repeat for each syrup 

line/pump.

14. 

Route proper drain line from the designated floor drain 

through the counter cutout and drip tray opening.

15. 

Connect drain tube to the drain fitting located on the        

bottom of the drip tray and secure drain tube with clamp.  

Содержание CED-04

Страница 1: ...demark of Lancer 2016 by Lancer all rights reserved 500 Lancer Corporation 6655 Lancer Blvd San Antonio Texas 78219 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancerc...

Страница 2: ...s a hazardous situation which if not avoided will result in death or serious injury Be sure to read all Warning statements before proceeding with the installation WARNING Text following the Caution si...

Страница 3: ...ualified personnel should service internal components of electrical control housing WARNING Make sure that all water lines are tight and units are dry before making any electrical connections If this...

Страница 4: ...59 42 kg ELECTRICAL 115 VAC 60 Hz 5 0 Amps PLAIN WATER SUPPLY Min Flowing Pressure 50 PSIG 0 345 MPA CARBONATED WATER SUPPLY Min Flowing Pressure 25 PSI 0 172 MPA Max Static Pressure 50 PSI 0 345 MPA...

Страница 5: ...r PN 82 3401 or MC 163172 Water Regulator recommended CONSIDER THE FOLLOWING BEFORE INSTALLATION Location of Water Supply Lines Location of Drain Location of Electrical Outlet Location of Heating and...

Страница 6: ...location that is in close proximity to a properly grounded electrical outlet within five 5 feet 1 5 m of a drain and a water supply that meets the requirements shown in the Specifications section foun...

Страница 7: ...sert water line into a large bucket and fill with approx 5 4 gallons 20 4 L of distilled water 9 Add 1 8 oz 4 g of baking soda to distilled water and stir A B C A Bucket B Distilled Water approx 5 4 g...

Страница 8: ...l devices on the same outlet WARNING 19 Turn on the power switch at the top of the unit to turn on the unit and begin building an ice bank Installing Remote Syrup Pumps Bag in Box A B C A Syrup Pump B...

Страница 9: ...ulk system 2 Connect a 1 4 nut stem and seal to CO2 regulator outlet Then connect tubing routed from tee at syrup pumps tanks A CO2 Regulator B Fitting C Line to CO2 Regulator Manifold D Oetiker Plier...

Страница 10: ...oz in 4 sec Use a screwdriver to adjust if needed 3 Remove nozzle by twisting counter clockwise and pulling down then remove diffuser by pulling down 4 Install Lancer yellow syrup separator PN 54 003...

Страница 11: ...IZING Lancer equipment new or reconditioned is shipped from the factory cleaned and sanitized in accordance with NSF guidelines The operator of the equipment must provide continuous maintenance as req...

Страница 12: ...BIB s 2 Place syrup lines with BIB connectors in a bucket of warm water 3 Activate each valve to fill the lines with warm water and flush out syrup remaining in the lines 4 Prepare Cleaning Solution d...

Страница 13: ...flow control 5 Bad syrup pump 1 Adjust CO2 pressure to 80 PSI 0 550 MPA minimum 70 PSI 0 480 MPA for BIB pumps 2 Replace CO2 tank refill 3 Open shutoff fully 4 Remove syrup flow control form upper bo...

Страница 14: ...3 Melt ice bank Remove all water Refill Locate possible syrup leak area and repair 4 Reposition water cage 5 Find leak and recharge unit If unit is not frozen 6 Turn water ON and shut unit OFF 7 Turn...

Страница 15: ...y 3 Refrigeration system not running 4 Refrigerant leak 5 Gas Cooler fan motor not working 6 Dirty Gas Cooler 7 Dispenser capacity exceeded 1 Check clearances around sides top and inlet of unit Remove...

Страница 16: ...w 90 of rated voltage 2 Refer to wiring diagram and correct 3 Replace starting relay Be sure to use correct relay Failure to use correct relay will cause compressor failure Compressor starts and runs...

Страница 17: ...upply or adjust CO2 pressure to 70 80 PSI 0 483 0 552 MPA 2 Replace syrup supply 3 Fasten connector tightly 4 Straighten or replace lines 5 Replace BIB pump BIB pump operated but no flow 1 Leak in syr...

Страница 18: ...hen back ON again to reset Carbonator timer Again measure continuity of the PCB screw lug connections Terminal 3 to 4 Carbonator During the first 2 5 to 3 5 minutes there should be continuity After 2...

Страница 19: ...19 INTENTIONALLY LEFT BLANK...

Страница 20: ...20 04 05 06 09 16 18 10 01 02 03 07 08 11 12 13 15 14 17 ILLUSTRATIONS AND PART LISTINGS Main Unit Assembly...

Страница 21: ...rup 1 CED 04 48 3551 Tube Assembly Syrup 2 CED 04 48 3550 Tube Assembly Syrup 3 CED 04 48 3572 Tube Assembly Syrup 4 CED 04 09 82 4563 Tank 10 82 0025 01 Leg Set 4 legs w o hardware 11 01 2115 01 Over...

Страница 22: ...1553 01 Fan Motor Bracket 03 82 5067 Agitator Assembly 04 30 12717 Agitator Motor Bracket 05 52 3690 Control Housing Assembly 06 25 0047 01 Transformer 07 52 1773 02 EIBC Probe Assembly 08 52 3485 Con...

Страница 23: ...23 Wiring Diagram 115 Volt...

Страница 24: ...Plumbing Diagram Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Отзывы: