BEFORE GETTING STARTED

Each unit is tested under operating conditions and is thoroughly 

inspected before shipment. At the time of shipment, the carrier 

accepts responsibility for the unit. Upon receiving the unit,    

carefully inspect the carton for visible damage. If damage exists, 

have the carrier note the damage on the freight bill and file a 

claim with carrier. Responsibility for damage to the dispenser lies 

with the carrier.

IMPORTANT SAFETY INSTRUCTIONS

The installation and relocation, if necessary, of this product must be carried out by qualified personnel with 

up-to-date safety and hygiene knowledge and practical experience, in accordance with current regulations.

LANCER PN: 28-2854/03

Revision: March 2018

®

4500

FOR QUALIFIED INSTALLER ONLY.

 This basic Installation Sheet is an initial release. If a complete Operations 

Manual (for the unit being installed) is required or needed, please refer to the Lancer web site (lancercorp.com) for 

immediate access, or for your convenience, scan this QR code with a mobile device (app required) for immediate 

access to other Technical Documents and alternative translations (if available) pertaining to this unit. Contact Lancer 

Customer Service for assistance as required.

The dispenser is for indoor use only. This unit is not a toy. Children should be supervised not to play with appliance. It should not 

be used by children or infirm persons without supervision. This appliance is not intended for use by persons (including children) 

with reduced physical, sensory or mental capabilities, or lack of experience and knowledge, unless they have been given 

supervision or instruction concerning use of the appliance by a person responsible for their safety. Cleaning and user maintenance 

shall not be performed by children without supervision. The min/max ambient operating temperature for the dispenser is 40°F to 

105°F (4°C to 41°C). Do not operate unit below minimum ambient operation conditions. Should freezing occur, cease operation of 

the unit and contact authorized service technician. Service, cleaning and sanitizing should be accomplished only by trained 

personnel. Applicable safety precautions must be observed. Instruction warnings on the product being used must be followed.

Intended Use

Units are equipped with an automatic agitation system and will activate unexpectedly. Do not place hands or foreign objects in the 

ice bin. Unplug the dispenser during servicing, cleaning, and sanitizing. To avoid personal injury, do not attempt to lift the dispenser 

without assistance. For heavier dispensers, use a mechanical lift.

Automatic Agitation

- Blue Star CB Series 25”

- Renew IBD CB Series 25”

- Renew Shot IBD CB Series 30”

Содержание Blue Star IBD CB Series 22

Страница 1: ...lancercorp com for immediate access or for your convenience scan this QR code with a mobile device app required for immediate access to other Technical Documents and alternative translations if availa...

Страница 2: ...arbonator Inlet 3 8 inch barb Plain Water Inlet 3 8 inch barb Brand Syrup Inlets 3 8 inch barb CO2 Inlet 3 8 inch barb ELECTRICAL 115 VAC 60 Hz 3 6 Amps 230 VAC 50 60 Hz 1 5 Amps PLAIN WATER SUPPLY Mi...

Страница 3: ...he 25 8 valve dispensers have space restrictions so the two center valves are plumbed only for carbonated watered drinks and are non adjustable NOTE A B C E A Plain Water ON D Water Closed B Carb Wate...

Страница 4: ...ed location should be able to support the weight of the dispenser ice and possibly an icemaker being installed after counter cut out is made Total weight with icemaker for this unit could exceed 800 p...

Страница 5: ...et of the proper voltage and amperage rating DO NOT PLUG UNIT INTO GROUNDED ELECTRICAL OUTLET AT THIS TIME Make sure that all water lines are tight and unit is dry before making any electrical connect...

Страница 6: ...2 regulator manifold A B C D A Line to Dispenser B Line to Syrup Pumps C Line to CO2 Regulator D CO2 Regulator Manifold DO NOT TURN ON CO2 SUPPLY AT THIS TIME WARNING 7 Repeat Step 6 on the previous p...

Страница 7: ...isting counter clockwise and pulling down then remove diffuser by pulling down 5 Install Lancer yellow syrup seperator PN 54 0031 in place of nozzle The pump deck has a 3 minute timeout feature If the...

Страница 8: ...es when cleaning and sanitizing syrup lines to avoid contamination DO NOT use strong bleaches or detergents These can discolor and corrode various materials DO NOT use metal scrapers sharp objects ste...

Страница 9: ...10 Wearing sanitary gloves soak and clean cloth towel in Sanitizing Solution and wash all surfaces of removable parts sides of the Ice Bin Auger and surface of the aluminum casting 11 Using the Saniti...

Страница 10: ...to flush solution from the dispenser 11 Taste the drink to verify that there is no off taste If off taste is found flush syrup system again 9 Place syrup lines into sanitizing solution and activate ea...

Страница 11: ...hown Syrup Lines Not Shown 30 10 Valve To prevent possible harm to the environment from improper disposal recycle the unit by locating an authorized recycler or contact the retailer where the product...

Страница 12: ...WIRING DIAGRAM Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Отзывы: