ADA STANDARDS FOR ACCESSIBLE DESIGN

To assure that beverage service is accessible to all customers, Lancer recommends that counter height

and equipment selection be planned carefully. The 2010 ADA Standards for Accessible Design states

the maximum reach height from the floor should be no more than 48” if touch point is less than 10” from the

front of the counter, or a maximum of 46” if the touch point is more than 10” and less than 27” from the front of the

counter (See Fig 1). For more information about the customer’s legal requirements for the accessibility of installed

equipment, refer to 2010 ADA Standards for Accessible Design - http://www.ada.gov.

!

!

WATER NOTICE/AGUA AVISO/ PRÉAVIS DE L’EAU

Provide an adequate potable water supply. Water pipe connections and fixtures directly connected to a potable 

water supply must be sized, installed, and maintained according to federal, state, and local laws. The water supply

line must be at least 3/8 inches (9.525 mm) pipe with a minimum of 20 PSI (0.137 MPA) line pressure, but not

exceeding a maximum of 50 PSI (0.345 MPA). Water pressure exceeding 50 PSI (0.345 MPA) must be reduced to

50 PSI (0.345 MPA) with the provided pressure regulator. Use a filter in the water line to avoid equipment damage 

and beverage off-taste. Check the water filter periodically, as required by local conditions. The water supply must be 

protected by means of an air gap, a backflow prevention device (located upstream of the CO2 injection system) or 

another approved method to comply with NSF standards. A leaking inlet water check valve will allow carbonated 

water to flow back through the pump when it is shut off and contaminate the water supply. Ensure the backflow 

prevention device complies with ASSE and local standards. It is the responsibility of the installer to ensure 

compliance.

Proporcione un suministro adecuado de agua potable. La línea de suministro de agua debe ser de una tubería de

por lo menos 3/8 pulgadas (9.525 mm) con una presión de línea mínima de 20 PSI (0.137 MPA) , pero sin superar

el máximo de 50 PSI (0.345 MPA). La presión de agua que supere los 50 PSI se debe reducir a 50 PSI (0.345 MPA) 

con un regulador de presión. Use un filtro en la línea de agua para evitar daños al equipo y cierto sabor raro en las

bebidas. Verifique periódicamente el filtro de agua de acuerdo con las condiciones imperantes. El suministro de

agua debe estar protegido por una separación de aire, un dispositivo de prevención del contraflujo (situado antes

del sistema de inyección de CO2) u otro método aprobado para cumplir las normas NSF. Si la válvula de retención

de entrada de agua tuviera pérdidas, permitiría el contraflujo del agua carbonatada a través de la bomba cuando se

la detiene y contaminaría el suministro de agua. Asegúrese de que el dispositivo de prevención del contraflujo

cumpla con las normas locales y de ASSE. Es responsabilidad del instalador cumplir con estos requisitos.

Fournissez une alimentation en eau potable adéquate. Les connexions et les dispositifs de conduite d’eau 

connectés directement à une alimentation en eau potable doivent être calibrés, installés et maintenus selon les lois

fédérales, provinciales et locales. La conduite d’alimentation en eau doit être un tuyau d’au moins 3/8 pouces (9.525

millimètres) avec une pression de ligne minimum de 20 LPC (0.137 MPA) , mais ne doit pas dépasser un maximum

de 50 LPC (0.345 MPA). Une pression d’eau de plus de 50 LPC (0.345 MPA) doit être réduite à 550 LPC (0.345 

MPA) avec le régulateur de pression fourni. Utilisez un filtre dans la conduite d’eau pour éviter des dommages à 

l’équipement et un goût des boissons qui n’est pas juste. Vérifiez le filtre à eau périodiquement, selon les exigences 

des conditions locales. L’alimentation en eau doit être protégée au moyen d’un intervalle d’air, un disconnecteur 

hydraulique (situé en amont du système d’injection de CO2) ou une autre méthode approuvée pour se conformer 

aux normes de la NSF. Un clapet antiretour pour l’eau entrante qui fuie permettra à l’eau gazeuse de repasser par 

la pompe quand elle est fermée et de contaminer l’alimentation en eau. Assurez-vous que le disjoncteur hydraulique 

soit conforme aux normes de l’ASSE et locales. L’installateur est responsable d’assurer la conformité.

!

!

Содержание 85-3151R-VV

Страница 1: ...1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com Manual PN 28 0883 03 DIGITAL RELEASE ONLY MAY 2013 FOR QUALIFIED INSTALLER ONLY UNICORN TOWER Operation Manual PN 28...

Страница 2: ...1 CLEANING SANITIZING SOLUTIONS 15 4 2 DAILY CLEANING 15 4 3 WEEKLY CLEANING SANITIZING 16 4 4 CLEANING AND SANITIZING BEVERAGE COMPONENTS BAG IN BOX SYSTEMS 17 5 PROGRAMMING OVERVIEW 18 5 1 PROGRAMM...

Страница 3: ...LECTRICAL REQUIREMENTS Refer to CONNECTING TO ELECTRICAL SUPPLY on pg 13 WEIGHT Shipping 35 lbs 15 88 kg Counter Weight 40 lbs 18 1 kg FITTINGS Soda Plain water inlet 1 4 barb Brand syrup inlets 1 4 b...

Страница 4: ...any internal maintenance The resettable breaker switch should not be used as a substitute for unplugging the dispenser from the power source to service the unit Only qualified personnel should servic...

Страница 5: ...sin superar el m ximo de 50 PSI 0 345 MPA La presi n de agua que supere los 50 PSI se debe reducir a 50 PSI 0 345 MPA con un regulador de presi n Use un filtro en la l nea de agua para evitar da os al...

Страница 6: ...inimo 25 PSIG 0 172 MPA Maximo 50 PSIG 0 345 MPA En unidades sin regulador de presi n incorporado si la presi n del agua es superior a 50 PSIG 0 345 MPA se debe usar un regulador de presi n 3 Los enva...

Страница 7: ...BIB Regulator Set BIB Connectors verify correct amount for syrup lineup BIB Syrup Boxes Remote Cooling Carbonation System THIS MANUAL APPLIES TO THE FOLLOWING UNITS 85 3151R 21 11111 00 TOWER UNICORN...

Страница 8: ...ADA Standards for Accessible Design states that the maximum reach height from the floor should be no more than 48 if touch point is less than 10 from the front of the counter or a maximum of 46 if th...

Страница 9: ...drip tray Fig 3b Position the font with the Selection Buttons and Nozzle above the Drip Tray 3 Route Ribbon Cable Wire Harnesses and Plumbing Lines through the nut Next thread nut on shank and tighten...

Страница 10: ...nsure adequate slack remains for connection lines to accommodate sliding the Box forward for servicing 2 Secure the Mounting Bracket to bottom of counter with four screws Fig 5 3 Align the Junction Bo...

Страница 11: ...e Unicorn Font to the appropriate connection in the Junction Box c Connect the Ribbon Cable PN 52 3346 to the Main Board PN 64 5048 space labeled J8 in the Junction Box d Connect the Power Wire Harnes...

Страница 12: ...ource supplying soft water This will cause excessive foaming B JUNCTION BOX PLUMBING LINE CONNECTIONS FOR LFCV NOTE It is recommended that the that plumbing lines to font are routed out rear of Juncti...

Страница 13: ...Junction Box Water Inlet and Outlets Insulate the tubing C DRAIN Route and connect drain tubing between font drip tray and facility drain Follow all local health and safety codes when performing this...

Страница 14: ...E TROIS BRANCHES MISE LA TERRE SI AUCUNE PRISE DE COURANT LECTRIQUE TROIS TROUS N EST DISPONIBLE UTILISEZ UNE M THODE APPROUV E POUR METTRE L UNIT LA TERRE AL HACER LAS CONEXIONES RESPETE TODOS LOS C...

Страница 15: ...g is thorough using clean potable water at a temperature of 90 to 110 degrees F Extended lengths of product lines may require additional cleaning solution SANITIZING SOLUTION Prepare sanitizing soluti...

Страница 16: ...ZER IS USED DISSOLVE IT THOROUGHLY WITH HOT WATER PRIOR TO ADDING TO THE SYRUP SYSTEM ENSURE SANITIZING SOLUTION IS REMOVED FROM THE DISPENSER AS INSTRUCTED AVOID GETTING SANITIZING SOLUTION ON CIRCUI...

Страница 17: ...ystem may be required H Following the instructions as described in 4 1 above mix appropriate amount of sanitizing solution in a clean container Place syrup inlet line in container filled with sanitizi...

Страница 18: ...e of the circle Mode LED Red LED below the Size buttons Brand LED Green LEDs in each brand quadrant Water LED Green LED in the middle of the circle P C Pour Cancel depending on configuration activated...

Страница 19: ...to choose between carbonated C or non carbonated rink n F Press or to raise or lower desired ratio G Press enter button to save the setting into the valve memory AFTER PROGRAMMING IS COMPLETE 5 2 CON...

Страница 20: ...ging of water or syrup without shutting off the back block 1 If unit is in IDLE MODE without a selected Active Brand AND has not dispensed since unit was powered on the PURGE MODE can be accessed by p...

Страница 21: ...the volume from each programming step to the total drink size When the portion is dispensed from idle mode the entire drink is dispensed without pauses If unit has an Active Brand selected Calibrated...

Страница 22: ...adjust water flow control to 14oz in 8 seconds Adjust water module in clockwise to increase the flow or out counter clockwise to decrease the flow F With water volume correct turn on syrup brand supp...

Страница 23: ...e A Plug in 24 volt power supply B Open mounting block shut offs C Replace touch panel D Check fuse or replace circuit board E1 Replace coil if resistance is open or shorted E2 Verify connectors are l...

Страница 24: ...nsulation 8 ILLUSTRATIONS AND PARTS LISTINGS TOWER UNICORN T C PC CC LFCV SPARE PARTS LIST LIST 8 1 LFCV ELECTRONIC SPARE PARTS 24 8 2 LFCV NOZZLE SPARE PARTS 25 8 3 LFCV VALVE SPARE PARTS 26 8 4 WIRI...

Страница 25: ...CTRONIC LFCV SPARE PARTS 4 3 2 1 25 Item Part No Description 1 52 3344 HARN LFCV THRU CNTR VAL UNICORN 2 52 3358 HARNESS BYPASS UNICORN 3 64 5048 PCB ASSY MAIN BOARD UNICORN 4 05 1678 STANDOFF PCB REV...

Страница 26: ...ption 1 64 5057 PCB ASSY TOUCH PAD UNICORN W PORTION CONTROL 2 17 0647 01 SOLENOID 24 VDC 1 8 NPT 2WNC 3 05 2971 ELBOW qUICK CONNECT 1 4 X 1 8 4 02 0214 O RING 2 008 97 0999 5 81 0679 NOZZLE ASSY UNIC...

Страница 27: ...0267 02 VALVE ASSY LFCV 2 0 SODA GRY S 4 05 1385 ELBOW 5 DOLE X 2 BARB PLS 5 02 0089 O RING 2 012 97 0999 6 19 0266 02 VALVE ASSY LFCV 2 0 SYR BLK SC 7 04 1089 SCR 10 32 RH PH SL 1 000 8 82 2317 01 BL...

Страница 28: ...28 8 4 WIRING DIAGRAM LFCV...

Страница 29: ...Part No Description 1 52 3381 HARNESS WATER MODULE VV RECIRC UNICORN 2 52 3359 HARN SOLENOID KIP VV UNICRN 3 52 3360 HARN SOLENOIDS VV UNICORN 4 52 3358 HARNESS BYPASS UNICORN 5 64 5048 02 PCB ASSY MA...

Страница 30: ...109 97 0999 4 01 2762 FTG SODA OUTLET UNCRN 5 02 0005 O RING 2 010 97 0999 6 02 0214 O RING 2 008 97 0999 7 05 2929 FITTING INLET NOZZLE SYRUP 8 04 1639 SCREW 4 20X 250 IN PH PHILLIPS PLASTITIE 18 8...

Страница 31: ...VALVE SPARE PARTS LIST Item Part No Description 5 02 0005 O RING 2 010 97 0999 6 05 1386 ELBOW 375 DOLE X 2 BARB PLS 7 19 0398 SYRUP MODULE VOL 1 5 3 0 8 04 1089 SCR 10 32 RH PH SL 1 000 9 82 2317 01...

Страница 32: ...8 MISC SPARE VV PARTS LIST Item Part No Description 1 64 5057 PCB ASSY TOUCH PAD UNICORN W PORTION CONTROL 2 01 2757 FTG WYE 12ID UNCRN 3 01 2806 JG BULKHEAD CONNECTOR 3 8 S FIT X 3 8 S FIT 79000217 1...

Страница 33: ...33 8 9 WIRING DIAGRAM VV...

Страница 34: ...34 8 10 COUNTER CUTOUT TEMPLATE not to scale...

Страница 35: ...35 NOTES...

Страница 36: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Отзывы: