![lancer 85-3151R-VV Скачать руководство пользователя страница 13](http://html1.mh-extra.com/html/lancer/85-3151r-vv/85-3151r-vv_operation-manual_3493594013.webp)
13
Figure 10
2. LINE RUN - RECIRCULATING SYSTEM
NOTE:
REFER TO COOLING SYSTEMS MANUFACTURERS INSTALLATION INSTRUCTIONS.
A. SYRUP
- Route and connect beverage tubing between Recirculating System Syrup Outlet and
Junction Box Inlet. Repeat for each syrup.
B. WATER
- Route and connect beverage tubing between Recirculating System and Junction Box
Water Inlet and Outlets. Insulate the tubing.
C. DRAIN
- Route and connect drain tubing between font drip tray and facility drain. Follow all local
health and safety codes when performing this step.
D. CONNECT ‘Y’ FITTING
1. Route and connect beverage tubing between recirculation outlet and ‘Y’ fitting at Junction Box.
2. Route and connect beverage tubing between ‘Y’ fitting at Junction Box and recirculation inlet.
3. Route and connect beverage tubing between ‘Y’ fitting and Junction Box water inlet.
4. Insulate all tubing.