background image

21

  

I.   PROGRAM MODE

   NOTE:

 The unit supports separate portions with up to 1 topoff for each brand

 

 

If the unit has an Active Brand, the PROGRAM MODE can be accessed by pressing and holding 

both the SM and XL buttons.

 

 

• During PROGRAM MODE, the Mode LED blinks.

 

 

• During PROGRAM MODE and its sub-modes, all dispenses use the Active Brand.

 

 

• During PROGRAM MODE and its sub-modes, the information stored for a Size is ONLY for the

 

 

Active Brand

 

 

1.   Put desired amount of ice in cup, place cup under valve

 

 

2.   Press and hold the size to be programmed until cup fills to desired portion

 

 

3.   If a topoff is not recessary, return to Step 1 with a different size or press the Active Brand to exit

 

 

 

portion program mode and save the programmed sizes.

 

 

4.   Wait for foam to settle, then press and hold the size again to top off.

 

 

5.   Return to Step 1 with a different size or press the Active Brand to exit portion program mode

 

 

• The unit will default to IDLE MODE automatically, if the unit is NOT dispensing AND the last

 

 

button press AND last dispense

  

J.   CALIBRATED CUP PORTION CONTROL PROGRAMMING FOR VOLUMETRIC MODE

   NOTE:

 In this mode, the unit adds the volume from each programming step to the total drink size.

 

 

When the portion is dispensed from idle mode, the entire drink is dispensed without pauses.

 

 

If unit has an Active Brand selected, Calibrated Cup Portion Control Programming MODE can be

 

 

accessed by pressing and holding both the SM and LG buttons.

 

 

• During Calibrated Cup Portion Control Programming MODE, the Mode LED blinks.

 

 

• During Calibrated Cup Portion Control Programming MODE and its sub-modes, all dispenses use

 

 

the Active Brand.

 

 

• During Calibrated Cup Portion Control Programming MODE and its sub-modes, the information

 

 

stored for a Size is ONLY for the Active Brand.

 

 

1.  Place volume cup under nozzle.

 

 

2.  Press appropriate size and fill volume cup to a point just short of the calibration mark on the  

 

volume cup. LED will turn ‘on’ while programming an individual cup size

 

 

3.   Allow foam to settle, jog size button until liquid reaches the calibration mark on the volume cup.

 

 

4.   Press the Active Brand to end programming the selected cup size. LED will return to blinking.

 

 

5.   Start at step 1 with a different size or press the Active Brand to exit Program Mode and save  

 sizes.

 

 

• The unit will return to IDLE MODE automatically, if the unit’s last button press AND last dispense

 

 

were both at least 60 (sixty) seconds prior, the unit will save the programmed portions.

Содержание 85-3151R-VV

Страница 1: ...1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com Manual PN 28 0883 03 DIGITAL RELEASE ONLY MAY 2013 FOR QUALIFIED INSTALLER ONLY UNICORN TOWER Operation Manual PN 28...

Страница 2: ...1 CLEANING SANITIZING SOLUTIONS 15 4 2 DAILY CLEANING 15 4 3 WEEKLY CLEANING SANITIZING 16 4 4 CLEANING AND SANITIZING BEVERAGE COMPONENTS BAG IN BOX SYSTEMS 17 5 PROGRAMMING OVERVIEW 18 5 1 PROGRAMM...

Страница 3: ...LECTRICAL REQUIREMENTS Refer to CONNECTING TO ELECTRICAL SUPPLY on pg 13 WEIGHT Shipping 35 lbs 15 88 kg Counter Weight 40 lbs 18 1 kg FITTINGS Soda Plain water inlet 1 4 barb Brand syrup inlets 1 4 b...

Страница 4: ...any internal maintenance The resettable breaker switch should not be used as a substitute for unplugging the dispenser from the power source to service the unit Only qualified personnel should servic...

Страница 5: ...sin superar el m ximo de 50 PSI 0 345 MPA La presi n de agua que supere los 50 PSI se debe reducir a 50 PSI 0 345 MPA con un regulador de presi n Use un filtro en la l nea de agua para evitar da os al...

Страница 6: ...inimo 25 PSIG 0 172 MPA Maximo 50 PSIG 0 345 MPA En unidades sin regulador de presi n incorporado si la presi n del agua es superior a 50 PSIG 0 345 MPA se debe usar un regulador de presi n 3 Los enva...

Страница 7: ...BIB Regulator Set BIB Connectors verify correct amount for syrup lineup BIB Syrup Boxes Remote Cooling Carbonation System THIS MANUAL APPLIES TO THE FOLLOWING UNITS 85 3151R 21 11111 00 TOWER UNICORN...

Страница 8: ...ADA Standards for Accessible Design states that the maximum reach height from the floor should be no more than 48 if touch point is less than 10 from the front of the counter or a maximum of 46 if th...

Страница 9: ...drip tray Fig 3b Position the font with the Selection Buttons and Nozzle above the Drip Tray 3 Route Ribbon Cable Wire Harnesses and Plumbing Lines through the nut Next thread nut on shank and tighten...

Страница 10: ...nsure adequate slack remains for connection lines to accommodate sliding the Box forward for servicing 2 Secure the Mounting Bracket to bottom of counter with four screws Fig 5 3 Align the Junction Bo...

Страница 11: ...e Unicorn Font to the appropriate connection in the Junction Box c Connect the Ribbon Cable PN 52 3346 to the Main Board PN 64 5048 space labeled J8 in the Junction Box d Connect the Power Wire Harnes...

Страница 12: ...ource supplying soft water This will cause excessive foaming B JUNCTION BOX PLUMBING LINE CONNECTIONS FOR LFCV NOTE It is recommended that the that plumbing lines to font are routed out rear of Juncti...

Страница 13: ...Junction Box Water Inlet and Outlets Insulate the tubing C DRAIN Route and connect drain tubing between font drip tray and facility drain Follow all local health and safety codes when performing this...

Страница 14: ...E TROIS BRANCHES MISE LA TERRE SI AUCUNE PRISE DE COURANT LECTRIQUE TROIS TROUS N EST DISPONIBLE UTILISEZ UNE M THODE APPROUV E POUR METTRE L UNIT LA TERRE AL HACER LAS CONEXIONES RESPETE TODOS LOS C...

Страница 15: ...g is thorough using clean potable water at a temperature of 90 to 110 degrees F Extended lengths of product lines may require additional cleaning solution SANITIZING SOLUTION Prepare sanitizing soluti...

Страница 16: ...ZER IS USED DISSOLVE IT THOROUGHLY WITH HOT WATER PRIOR TO ADDING TO THE SYRUP SYSTEM ENSURE SANITIZING SOLUTION IS REMOVED FROM THE DISPENSER AS INSTRUCTED AVOID GETTING SANITIZING SOLUTION ON CIRCUI...

Страница 17: ...ystem may be required H Following the instructions as described in 4 1 above mix appropriate amount of sanitizing solution in a clean container Place syrup inlet line in container filled with sanitizi...

Страница 18: ...e of the circle Mode LED Red LED below the Size buttons Brand LED Green LEDs in each brand quadrant Water LED Green LED in the middle of the circle P C Pour Cancel depending on configuration activated...

Страница 19: ...to choose between carbonated C or non carbonated rink n F Press or to raise or lower desired ratio G Press enter button to save the setting into the valve memory AFTER PROGRAMMING IS COMPLETE 5 2 CON...

Страница 20: ...ging of water or syrup without shutting off the back block 1 If unit is in IDLE MODE without a selected Active Brand AND has not dispensed since unit was powered on the PURGE MODE can be accessed by p...

Страница 21: ...the volume from each programming step to the total drink size When the portion is dispensed from idle mode the entire drink is dispensed without pauses If unit has an Active Brand selected Calibrated...

Страница 22: ...adjust water flow control to 14oz in 8 seconds Adjust water module in clockwise to increase the flow or out counter clockwise to decrease the flow F With water volume correct turn on syrup brand supp...

Страница 23: ...e A Plug in 24 volt power supply B Open mounting block shut offs C Replace touch panel D Check fuse or replace circuit board E1 Replace coil if resistance is open or shorted E2 Verify connectors are l...

Страница 24: ...nsulation 8 ILLUSTRATIONS AND PARTS LISTINGS TOWER UNICORN T C PC CC LFCV SPARE PARTS LIST LIST 8 1 LFCV ELECTRONIC SPARE PARTS 24 8 2 LFCV NOZZLE SPARE PARTS 25 8 3 LFCV VALVE SPARE PARTS 26 8 4 WIRI...

Страница 25: ...CTRONIC LFCV SPARE PARTS 4 3 2 1 25 Item Part No Description 1 52 3344 HARN LFCV THRU CNTR VAL UNICORN 2 52 3358 HARNESS BYPASS UNICORN 3 64 5048 PCB ASSY MAIN BOARD UNICORN 4 05 1678 STANDOFF PCB REV...

Страница 26: ...ption 1 64 5057 PCB ASSY TOUCH PAD UNICORN W PORTION CONTROL 2 17 0647 01 SOLENOID 24 VDC 1 8 NPT 2WNC 3 05 2971 ELBOW qUICK CONNECT 1 4 X 1 8 4 02 0214 O RING 2 008 97 0999 5 81 0679 NOZZLE ASSY UNIC...

Страница 27: ...0267 02 VALVE ASSY LFCV 2 0 SODA GRY S 4 05 1385 ELBOW 5 DOLE X 2 BARB PLS 5 02 0089 O RING 2 012 97 0999 6 19 0266 02 VALVE ASSY LFCV 2 0 SYR BLK SC 7 04 1089 SCR 10 32 RH PH SL 1 000 8 82 2317 01 BL...

Страница 28: ...28 8 4 WIRING DIAGRAM LFCV...

Страница 29: ...Part No Description 1 52 3381 HARNESS WATER MODULE VV RECIRC UNICORN 2 52 3359 HARN SOLENOID KIP VV UNICRN 3 52 3360 HARN SOLENOIDS VV UNICORN 4 52 3358 HARNESS BYPASS UNICORN 5 64 5048 02 PCB ASSY MA...

Страница 30: ...109 97 0999 4 01 2762 FTG SODA OUTLET UNCRN 5 02 0005 O RING 2 010 97 0999 6 02 0214 O RING 2 008 97 0999 7 05 2929 FITTING INLET NOZZLE SYRUP 8 04 1639 SCREW 4 20X 250 IN PH PHILLIPS PLASTITIE 18 8...

Страница 31: ...VALVE SPARE PARTS LIST Item Part No Description 5 02 0005 O RING 2 010 97 0999 6 05 1386 ELBOW 375 DOLE X 2 BARB PLS 7 19 0398 SYRUP MODULE VOL 1 5 3 0 8 04 1089 SCR 10 32 RH PH SL 1 000 9 82 2317 01...

Страница 32: ...8 MISC SPARE VV PARTS LIST Item Part No Description 1 64 5057 PCB ASSY TOUCH PAD UNICORN W PORTION CONTROL 2 01 2757 FTG WYE 12ID UNCRN 3 01 2806 JG BULKHEAD CONNECTOR 3 8 S FIT X 3 8 S FIT 79000217 1...

Страница 33: ...33 8 9 WIRING DIAGRAM VV...

Страница 34: ...34 8 10 COUNTER CUTOUT TEMPLATE not to scale...

Страница 35: ...35 NOTES...

Страница 36: ...Lancer Corp 800 729 1500 Technical Support Warranty 800 729 1550 custserv lancercorp com lancercorp com...

Отзывы: