46
2. FAULT ALARMS
These alarms stop the operation of the washer. To clear the alarm mode, the washer
must be switched off by pressing
key.
N°1 P
ROBE FAULT
.
F
A
U L T
N °
0 1
P
R
O B E
D E F E C T
Probe Fault Definition :
The probe used to check the temperature of the water in the chamber is
disconnected or defective.
Corrective Action :
CONTACT A MAINTENANCE TECHNICIAN to check the electrical
connection and the condition of the probe.
N°2 E
MPTYING FAULT
.
F
A
U L T
n
°
0 2
E M P T Y
I N G
F A U L T
Emptying Fault Definition :
The washer has not been fully emptied at the end of the normal emptying
time defined in the Common Times menu.
Corrective Action :
Check that there is no restriction on the emptying line, that the emptying
pump (or the valve) and its pipes are not blocked and that the chamber
filters are not clogged.