PAGE 27

TROUBLESHOOTING

Problem

Possible Cause

Solution

1. No Display on PC Board

a. No power at electric outlet

a. Repair outlet or use working outlet

b. Control valve Power Adapter not plugged 

into outlet or power cord end not 

connected to PC board connection

b. Plug Power Adapter into outlet or connect 

power cord end to PC Board connection

c. Improper power supply

c. Verify proper voltage is being delivered to 

PC Board

d. Defective Power Adapter

d. Replace Power Adapter

e. Defective PC Board

e. Replace PC Board

2. PC Board does not display correct time of 

day

a. Power Adapter plugged into electric outlet 

controlled by light switch

a. Use uninterrupted outlet

b. Tripped breaker switch and/or tripped GFI

b. Reset breaker switch and/ or GFI switch

c. Power outage

c. Reset time of day. If PC Board has battery 

back up present the battery may be 

depleted. See Front Cover and Drive 

Assembly drawing for instructions.

d. Defective PC Board

d. Replace PC Board

3. Display does not indicate that water is 

flowing. Refer to user instructions for how the 

display indicates water is flowing

a. Bypass valve in bypass position

a. Turn bypass handles to place bypass in 

service position

b. Meter is not connected to meter connection 

on PC Board

b. Connect meter to three pin connection 

labeled METER on PC Board

c. Restricted/ stalled meter turbine

c. Remove meter and check for rotation or 

foreign material

d. Meter wire not installed securely into three 

pin connector

d. Verify meter cable wires are installed 

securely into three pin connector labeled 

METER

e. Defective meter

e. Replace meter

f. Defective PC Board

f. Replace PC Board

4. Control valve regenerates at wrong time 

of day

a. Power outage

a. Reset time of day. If PC Board has battery 

back up present the battery may be 

depleted. See Front Cover and Drive 

Assembly drawing for instructions.

b. Time of day not set correctly

b. Reset to correct time of day

c. Time of regeneration set incorrectly

c. Reset regeneration time

d. Control valve set at “on 0” (immediate 

regeneration)

d. Check programming setting and reset to 

NORMAL (for a delayed regen time)

e. Control valve set at “ on 0” 

(delayed and/ or immediate)

e. Check programming setting and reset to 

NORMAL (for a delayed regen time)

5. Time of day flashes on and off

a. Power outage

a. Reset time of day. If PC Board has battery 

back up present the battery may be 

depleted. See Front Cover and Drive 

Assembly drawing for instructions.

6. Control valve does not regenerate 

automatically when the REGEN button

a. Broken drive gear or drive cap assembly 

a. Replace drive gear or drive cap assembly

b. Broken Piston Rod

b. Replace piston rod

c. Defective PC Board

c. Defective PC Board

7. Control valve does not regenerate 

automatically but 

does

 when the REGEN 

button

a. Bypass valve in bypass position

a. Turn bypass handles to place bypass in 

service position

b. Meter is not connected to meter connection 

on PC Board

b. Connect meter to three pin connection 

labeled METER on PC Board

c. Restricted/ stalled meter turbine

c. Remove meter and check for rotation or 

foreign material

d. Incorrect programming

d. Check for programming error

e. Meter wire not installed securely into three 

pin connector

e. Verify meter cable wires are installed 

securely into three pin connector labeled 

METER

f. Defective meter

f. Replace meter

g. Defective PC Board

g. Replace PC Board

Содержание diamond 7-LXC-50B

Страница 1: ...free service When installed in accordance with the following instructions and if given reasonable care clear soft water will be the result For servicing and future inspection purposes please file this...

Страница 2: ...ss Note Add 4 grains per gallon of hardness for each ppm iron for total compensated hardness Total Grains per Day INSTALLATION DATE SERIAL NUMBER INSTALLER NAME PHONE ADDRESS TABLE OF CONTENTS Job Spe...

Страница 3: ...nt cement on any part of the o rings split rings bypass valve or control valve Plug into an electrical outlet Note All electrical connections must be connected according to local codes Be certain the...

Страница 4: ...the softener cannot be subject to a vacuum due to loss of pressure such as a water main break or submersible well pump check valve failure WATER TEMPERATURE The range of water temperature is 40 F to 1...

Страница 5: ...ility without the need for tools The bypass body and rotors are glass filled Noryl or equivalent and the nuts and caps are glass filled polypropylene All seals are self lubricating EPDM to help preven...

Страница 6: ...ical plumbing should be done in accordance to all local codes INSTALLATION INSTRUCTIONS BRINE LINE FITTING CONNECTIONS DRAIN LINE FITTING CONNECTION USING 5 8 POLY TUBE C l i c k t o b u y N O W PDF X...

Страница 7: ...the control valve with a locking clip The locking clip allows the elbow to rotate 270 degrees so the outlet can be oriented towards the brine tank 8 Connect the brine line polytubing found with the b...

Страница 8: ...HEATER DRAIN LINE AIR GAP ADAPTER COLD HOT LOCATE WATER SOFTENER AS CLOSE AS POSSIBLE TO BRINE TANK A SIX FOOT LENGTH OF 3 8 O D BRINE LINE POLYTUBE SUPPLIED WITH BRINE TANK LOCATE WATER SOFTENER CLO...

Страница 9: ...full is recommended SANITIZING Use 2 oz of 5 unscented household chlorine bleach for each cubic foot of resin Pour bleach directly into the 4 diameter white brine well located inside the brine tank P...

Страница 10: ...Set the amount of hardness in grains of hardness as calcium carbonate per gallon using the or buttons The default is 20 with value ranges from 1 to 150 in 1 grain increments Note The grains per gallon...

Страница 11: ...urn to previous digit Banner Text Set the banner text up to a maximum of 44 characters Use the or to select letters of the alphabet numbers ampersand or a space in the banner text Press NEXT to forwar...

Страница 12: ...Adaptor Input Voltage Hertz 120V AC 60 Hz AC Adaptor Output Voltage Current 12V AC 500 mA 3 Volt Lithium Coin Cell Battery type 2032 PC Board Relay Terminal Block DC Output Voltage 12V DC Relay Speci...

Страница 13: ...7 2 7 4 2 Brine Line Re Fill Flow Control GPM 0 5 0 5 0 5 0 5 0 5 Injector color 1C Violet 1E White 1E White 1F Blue 1H Green X FACTOR SERIES LXC SPECIFICATIONS MODEL NUMBER 7 LXC 50B PACKED BED 7 LX...

Страница 14: ...3 0 4 5 6 0 9 0 Medium 4 0 5 3 8 0 10 7 16 0 High 7 5 10 0 15 0 20 0 30 0 GALLONS WATER TO DRAIN at 40 50 60 PSI Inlet Pressure Low 38 4 39 6 40 4 60 8 62 5 63 8 61 5 63 3 64 5 94 5 96 3 98 0 142 5 14...

Страница 15: ...0 Re FILL Minutes Low 1 5 2 3 3 0 Medium 2 7 4 0 5 3 High 5 0 7 5 10 0 GALLONS WATER TO DRAIN at 40 50 60 PSI Inlet Pressure Low 18 5 20 0 21 3 60 4 62 1 63 4 26 8 28 5 29 8 Medium 19 0 20 6 21 8 61...

Страница 16: ...39 LBS Ion Exchange Resin for Model 7 LX 75B 1 A4074 1 Cu Ft 52 LBS Ion Exchange Resin for Model 7 LX 100B 1 A4074 1 1 2 Cu Ft 78 LBS Ion Exchange Resin for Model 7 LX 150B 1 A4074 2 Cu Ft 104 LBS Ion...

Страница 17: ...ging the power adapter from the wall Battery Fully Seated When replacing the battery align positives and push down to fully seat X FACTOR FRONT COVER AND DRIVE ASSEMBLY After completing any valve main...

Страница 18: ...on caps and or tap with a hammer 1 2 3 4 5 INJECTOR CAP INJECTOR SCREEN INJECTOR PLUG AND O RING Drawing No Order No Description Qty 1 V3005 Spacer Stack Assembly 1 2 V3004 Drive Cap Assy 1 3 V3178LP...

Страница 19: ...ith the service spanner wrench If necessary a pliers can be used to unscrew the nut or cap Do not use a pipe wrench to tighten or loosen nuts or caps Do not place a screwdriver in slots on caps and or...

Страница 20: ...r Assembly Drawing No Order No Description Quantity 1 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 2 3 V3105 O Ring 215 2 4 V3191 Vertical Adapter 2 INSTALLATION FITTING ASSEMBLIES 4 Water Flow Prop...

Страница 21: ...V3148 Bypass Rotor Seal Retainer 2 8 V3152 O ring 135 2 9 V3155 O ring 112 2 10 V3156 O ring 214 2 BYPASS VALVE Order No V3193 Although no tools are necessary to assemble or disassemble the valve the...

Страница 22: ...der No V3007 07 Description Fitting 1 1 PVC Solvent Assembly Drawing No Order No Description Quantity 1 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 2 3 V3105 O Ring 215 2 4 V3352 Fitting 1 1 PVC So...

Страница 23: ...abinetAsm_1 15 XX 1 64 MODEL 005 DWG X CabinetAsm_GeneralDim18 X XX X 0 5 Units Inch ORDERING INFORMATION The cabinet requires two part numbers when ordering one part number for the base assembly w sy...

Страница 24: ...esistance is felt before latching then notches are not fully engaged the piston rod is not in hole the wires are jammed between the drive bracket and drive back plate or the gear is not engaging the d...

Страница 25: ...n the drive cap assembly Continue to tighten the drive cap assembly using a screwdriver as a ratchet until the black o ring on the spacer stack assembly is no longer visible through the drain port Exc...

Страница 26: ...not be used to clean the injector Scoring the injector or increasing the diameter of the hole could change the operating parameters of the injector Push the plug s and or injectors firmly in place re...

Страница 27: ...ace meter f Defective PC Board f Replace PC Board 4 Control valve regenerates at wrong time of day a Power outage a Reset time of day If PC Board has battery back up present the battery may be deplete...

Страница 28: ...leaking fixtures that may be exhausting capacity or system is undersized 10 Residual regenerant being delivered to service a Low water pressure a Check incoming water pressure water pressure must rem...

Страница 29: ...supply from PC Board for 5 seconds and then reconnect c Missing reduction gears c Replace missing gears 15 Err 102 Control valve motor ran too short and was unable to find the next cycle position and...

Страница 30: ...or disconnect power supply from PC Board for 5 seconds and then reconnect Then re program valve to proper setting b MAV NHBP motor wire not connected to PC Board b Connect MAV NHBP motor to PC Board t...

Отзывы: