Troubleshooting:

 

TROUBLESHOOTING GUIDE

Symptom

Possible Causes

Solutions

Pressure Drop

Sediment pre-filter clogged

•  replace filter cartridge with appropriate 5 micron cartridge

Note: 

check source water supply as fluctuations may occur 

in source pressure

Flow regulator (not provided)

•  flow regulator will result in pressure drop when 

approaching full flow

High Bacteria 

Counts

Quartz sleeve is stained or dirty

• 

clean sleeve with scale cleaner and eliminate source of 

staining problem (ie. soften hard water, see page 9)

Change in feed water quality

• 

have source water tested to ensure that water quality is 

still within allowable limits for this system

Contamination in water lines after UV 

system

•  it is imperative that effluent water stream be shocked 

with chlorine (bleach) before water leaves UV system - 

disinfection system must have a bacterial free distribution 

system to work effectively (see page 8)

Possible break-through of sediment 

through pre-filter

• 

have source water tested for turbidity - may need 

stepped filtration in order to catch all sediment entering 

water system (20 micron filter followed by a 5 micron 

filter followed by UV system)

Heated 

Product Water

Common problem caused by 

infrequent use of water; water sitting in 

UV chamber and heating up

• 

run water until it returns to ambient temperature

Excessive 

Heat 

Generated

Water temperature is too high

• 

Ensure treatment is on cold water side only (prior to 

heating of water)

Water Appears 

Milky

Caused by air in the water lines

• 

run water until air is purged

Unit Leaking 

Water

Problem with o-ring seal on gland nut

•  ensure o-ring is in place, check for cuts or abrasions, 

clean o-ring, moisten with water and re-install, replace if 

necessary

Condensation on reactor chamber 

caused by excessive humidity & cold 

water

•  check location of disinfection system and control humidity

Inadequate (misaligned or cross-

threaded) inlet/outlet port connections

•  check thread connections, reseal with Teflon® tape and 

re-tighten

Water hammer causing pressure 

spikes

• 

Install a “water hammer” arrestor in the plumbing system

System 

Shutting Down 

Intermittently

Interrupted power supply

• 

ensure system has been installed on its own circuit, as 

other equipment may be drawing power away from UV 

(ie. pump or refrigerator)

• 

UV system should not be installed on a circuit which is 

incorporated into a light switch

Lamp Failure 

Alarm on - 

New Lamp

Loose connection between lamp and 

connector

• 

disconnect lamp from connector and reconnect, ensuring 

that a tight fit is accomplished

Moisture build up in connector may 

keep lamp and connector from making 

a solid connection

• 

eliminate chanc  e of any moisture getting to the connector 

and/or lamp pins

No Power to 

Ballast

GFCI wall socket is tripped

• 

Reset, following GFCI manufacturer’s instructions

•  Check socket with other applications

Содержание 7-LWT-UV009

Страница 1: ...RTIFIED PLUMBER IS RECOMMENDED In the event that you need assistance for servicing your UV system please first contact the professional contractor who installed the system Congratulations on purchasing your new Lancaster Water UV Disinfection System This unit is designed to give you many years of trouble free service For servicing and future inspection purposes please file this booklet with your i...

Страница 2: ...rforming any cleaning or maintenance activities Never yank the cord to remove from an outlet grasp the wall plug and pull to disconnect 8 Do not use this disinfection system for other than intended use potable water application The use of attachments not recommended or sold by the manufacturer distributor may cause an unsafe condition 9 Intended for indoor use only Do not install this disinfection...

Страница 3: ...t a lower performance than intended Qty 2 21S UV Electronic Ballast Mounting Screw Qty 2 21A UV Electronic Ballast Mounting Anchor Ground Screw attached Model SS UV Chamber Domed Quartz Sleeve length 7 LWT UV009 7 LWT UV016 7 LWT UV030 100 UV 200 UV 300 UV 7 Q6 13 1 8 7 Q10 21 3 8 7 Q20 34 3 4 UV Lamp A Four pins 7 L6 11 13 16 7 L10 20 1 16 7 L20 33 3 16 18 UV Lamp Compression Spring 14 UV Aluminu...

Страница 4: ...ONIC BALLAST CONTROLLER MODEL 7 LWT UV009 7 LWT UV016 7 LWT UV030 INLET OUTLET A B C D E F DIA 1 0 MNPT 1 0 MNPT 1 5 MNPT 3 1 2 3 1 2 3 1 2 5 17 3 8 13 3 8 1 3 8 13 9 16 5 25 5 8 21 11 16 21 13 16 1 3 8 5 1 4 2 1 8 39 3 4 35 1 16 35 9 16 C l i c k t o b u y N O W PDF XCHANGE w w w docu track c o m C l i c k t o b u y N O W PDF XCHANGE w w w docu track c o m ...

Страница 5: ...ctor POWER CONSUMPTION 34 W 29 W 45 W 50 W 90 W 80 W LAMP WATTS LAMP TYPE LOW PRESSURE HIGH OUTPUT LPHO ELECTRICAL MAXIMUM OPERATING PRESSURE 125 PSI AMBIENT AIR WATER TEMPERATURE 36 to 104 F PRESSURE DROP at 30mJ cm RATED FLOW 2 LESS THAN 1 PSI CHAMBER MATERIAL 304 SS INLET OUTLET PORT SIZE 1 0 MNPT 1 0 MNPT 1 5 MNPT STEADY WORK GREEN LED LAMP ON INDICATOR LAMP LIFE REMAINING DAYS CONTINUES TO BE...

Страница 6: ...llation is vertical with the lamp connector on top This is to prevent water damage from occurring on the lamp connector and lamp pins Leave space at least equal to the overall length of the disinfection system to allow clearance for the removal and replacement of the lamp and or quartz sleeve The electronic ballast should be mounted either above or beside the stainless steel UV reactor chamber Nev...

Страница 7: ...y Ensure that the flow of the water matches the flow direction as indicated on the flow restrictor DO NOT SOLDER CONNECTIONS WHILE ATTACHED TO THE SYSTEM AS THIS COULD DAMAGE THE O RING SEALS 5 Mount the electronic ballast controller horizontally to the wall near the UV reactor chamber Ideally place the controller above the reactor and away from any water connection point to prevent any water from...

Страница 8: ...rom the system until no chlorine smell is detectable Make sure that each fixture that was disinfected in step two is completely flushed of the chlorine solution as the consumption of the water is not advised due to the extremely high concentrations of chlorine It is important to remember that in the event that a UV is briefly shut down for a routine cleaning or during power interruptions where wat...

Страница 9: ...TER LAMP REPLACEMENT PG 9 refer to www lamprecycle org for lamp disposal QUARTZ SLEEVE REPLACEMENT CLEANING Mineral deposits and sediment may accumulate on the quartz sleeve decreasing the UV light transmittance and system performance Good maintenance of filtration equipment will reduce the accumulation of residues If necessary remove the quartz sleeve and clean with a commercially available scale...

Страница 10: ...und again if the lamp has not been replaced The alarm can be silenced up to 4 times 28 days After 4 times the alarm can no longer be silenced until a replacement lamp is installed and the lamp life timer is reset RESET LAMP LIFE TIMER AFTER LAMP REPLACEMENT After replacing the lamp by following instructions on the previous page reset the lamp life timer to 365 days by pressing and holding the butt...

Страница 11: ...OUND SCREW UNDER BALLAST U CLIP BUSHING LAMP CONNECTOR ALUMINUM GLAND NUT LAMP COMPRESSION SPRING O RING QUARTZ SLEEVE GROUND NUT UV LAMP GROUND WIRE RING TERMINAL STAINLESS STEEL UV CHAMBER QUARTZ SLEEVE DOMED END Refer to PRODUCT OVERVIEW page for replacement part numbers GROUND WIRE FORK TERMINAL ...

Страница 12: ...emperature Excessive Heat Generated Water temperature is too high Ensure treatment is on cold water side only prior to heating of water Water Appears Milky Caused by air in the water lines run water until air is purged Unit Leaking Water Problem with o ring seal on gland nut ensure o ring is in place check for cuts or abrasions clean o ring moisten with water and re install replace if necessary Co...

Страница 13: ...PAGE 13 A DIVISION OF C B TOOL CO 1340 MANHEIM PIKE LANCASTER PA 17601 3196 TEL 717 397 3521 FAX 717 392 0266 www lancasterwatergroup com E mail info lancasterwatergroup com 3 18 ...

Отзывы: