background image

PAGE 12

WATER METER AND METER PLUG

Item No. Quantity

Part No.

Description

1

1

V3151

Nut 1” QC

2

1

V3003*

Meter Assy

3

1

V3118-01

Turbine Assy

4

1

V3105

O-Ring 215

5

1

V3003-01

Meter Plug Assy

*Part No. V3003 includes Items 2, 3 and 4

DRAIN LINE - 3/4” 

Item No. Quantity

Part No.

Description

1

1

H4615

Elbow Locking Clip

2

1

V3194

Polytube Insert 5/8

3

1

V3192

Nut  for 3/4 Drain Elbow

4

1

V3158

3/4 Drain Elbow

5

1

V3163

O-Ring 019

6

1

V3159

DLFC Retainer

7

1

V3162-010

DLFC 1.0

7

1

V3162-017

DLFC 1.7

7

1

V3162-027

DLFC 2.7

7

1

V3162-032

DLFC 3.2

7

1

V3162-042

DLFC 4.2

BRINE REFILL

Item No.

Qty,

Part No.

Description

1

1

H4615

Elbow Locking Clip

2

1

H4628

Elbow 3/8” Liquifit

3

1

V3163

O-ring 019

4

1

V3165-01* RFC Retainer Assy (0.5 gpm)

5

1

V3182

RFC

6

1

V4144-01

Elbow 3/8 Liquifit Assy w/RFC

*Assembly includes V3182 RFC. 

WS1 & WS1.25 Drawings & Service Manual 

Page 17

Water Meter, Meter Plug and Mixing Valve

Drawing No.

Order No.

Description

Quantity

1

V3151

WS1 Nut 1” QC

1

2

V3003*

WS1 Meter ASY

1

3

V3118-01

WS1 Turbine ASY

1

4

V3105

0-ring 215

1

5

V3003-01

WS1 Meter Plug ASY

1

6

V3013

Mixing Valve

Optional

*Order number V3003 includes V3118-01 WS1 Turbine ASY and V3105 O-ring 

215.

3

4

5

1

2

6

THIS WATER METER SHOULD NOT BE USED AS THE PRIMARY MONITORING DEVICE FOR CRITICAL HEALTH 
EFFECT APPLICATIONS.

NOTE: A water meter is not applicable for a TC control valve.

WS1 & WS1.25 Drawings & Service Manual 

Page 15

Drain Line – 3/4”

Water 
Flow

Proper DLFC orientation 
directs water  ow towards 
the washer face with 
rounded edge.

Drawing No.

Order No.

Description

Quantity

1

H4615

Elbow Locking Clip

1

2

PKP10TS8-BULK

Polytube insert 5/8

Option

3

V3192

WS1 Nut ¾ Drain Elbow

Option

4*

V3158-01

WS1 Drain Elbow ¾ Male

1

5

V3163

O-ring 019

1

6*

V3159-01

WS1 DLFC Retainer ASY

1

7

V3162-007

WS1 DLFC 0.7 gpm for ¾

One DLFC 

must be 

used if ¾ 

 tting is 

used

V3162-010

WS1 DLFC 1.0 gpm for ¾

V3162-013

WS1 DLFC 1.3 gpm for ¾

V3162-017

WS1 DLFC 1.7 gpm for ¾

V3162-022

WS1 DLFC 2.2 gpm for ¾

V3162-027

WS1 DLFC 2.7 gpm for ¾

V3162-032

WS1 DLFC 3.2 gpm for ¾

V3162-042

WS1 DLFC 4.2 gpm for ¾

V3162-053

WS1 DLFC 5.3 gpm for ¾

V3162-065

WS1 DLFC 6.5 gpm for ¾

V3162-075

WS1 DLFC 7.5 gpm for ¾

V3162-090

WS1 DLFC 9.0 gpm for ¾

V3162-100

WS1 DLFC 10.0 gpm for ¾

Valves are shipped without drain line  ow control (DLFC) - install DLFC before using. Valves 
are shipped without ¾ nut for drain elbow (polytube installation only) and 5/8" polytube insert 
(polytube installation only).

4

*4 and 6 can be ordered as a complete assembly - V3331 WS1 Drain Elbow and Retainer Asy











Drawing No.

Order No.

Description

Quantity

1

V3195-01

WS1 Refi ll Port Plug Asy

This part is required for backwash only systems

2

H4615

Elbow Locking Clip

1

3

H4628

Elbow 3/8” Liquifi t

1

4

V3163

0-ring 019

1

5

V3165-01*

WS1 RFC Retainer Asy (0.5 gpm)

1

6

V3182

WS1 RFC

1

7

V4144-01

Elbow 3/8 Liquifi t Asy w/RFC

1

Not Shown

V3552

WS1 Brine Elbow Asy w/RFC   

Option

Not Shown

H4650

Elbow ½” with nut and insert

Option

*Assembly includes V3182 WS1 (0.5 gpm) RFC.

















4

6

2

3

1

5

Содержание X FACTOR GOLD LINE LER

Страница 1: ...r This unit is designed to give you many years of trouble free service When installed in accordance with the following instructions and if given reasonable care clear soft water will be the result For...

Страница 2: ...ne prior to connecting the drain line flow control fitting Leave at least 6 between the drain line control fitting and solder joints when soldering pipes that are connected on the drain line control f...

Страница 3: ...er supply inlet after pressure tank and near a source for waste water utility sink floor drain or sewer line A 115 120V 60 Hz uninterrupted outlet is required Keep softener far enough away from walls...

Страница 4: ...of the overflow Do not connect the tubing to the drain line on the control valve Do not run tubing above overflow height at any point PROGRAMMING THE CONTROL VALVE Note A quick reference card is stor...

Страница 5: ...Set the amount of hardness in grains of hardness as calcium carbonate per gallon using the or buttons The default is 20 with value ranges from 1 to 150 in 1 grain increments Note The grains per gallon...

Страница 6: ...g steadily to drain without the presence of air momentarily press REGEN again Display will read RINSE Open the outlet valve of the softener or if using optional bypass place to NORMAL OPERATION MODE f...

Страница 7: ...is required The bypass consists of two interchangeable plug valves that are operated independently by red arrow shaped handles The handles identify the flow direction of the water The plug valves ena...

Страница 8: ...reinstall the PC board position the lower edge of the PC board so that the holes in the PC board line up with the plastic pins Push the top of the PC board towards the valve until it snaps under the...

Страница 9: ...atent 6402944 is a one piece design which allows the stack to be removed using your fingers The exterior of the stack is sealed against the body bore with self lubricating EPDM o rings while the inter...

Страница 10: ...l flow control assembly is installed in an easy to access refill elbow located on top of the control valve The refill flow control assembly is attached to the control valve with a locking clip The loc...

Страница 11: ...y E White 5 1 V3010 1F Injector Assy F Blue 5 1 V3010 1G Injector Assy G Yellow Not Shown V3170 O Ring 011 Not Shown V3171 O Ring 013 Injector plug and injector each contain one 011 and one 013 O Ring...

Страница 12: ...lbow Locking Clip 1 2 PKP10TS8 BULK Polytube insert 5 8 Option 3 V3192 WS1 Nut Drain Elbow Option 4 V3158 01 WS1 Drain Elbow Male 1 5 V3163 O ring 019 1 6 V3159 01 WS1 DLFC Retainer ASY 1 7 V3162 007...

Страница 13: ...Description 1 2 V3151 Nut 1 Quick Connect 2 2 V3150 Split Ring 3 2 V3105 O Ring 215 4 2 V3149 1 PVC Male NPT Elbow Item No Qty Part No Description 1 1 H4600 3 8 Safety Brine Valve 2 2 10151 Pin 3 1 H4...

Страница 14: ...jack black wire and plug back in to reset control valve e Motor not inserted fully to engage pinion motor wires broken or disconnected motor failure e Check motor and wiring Replace motor if necessar...

Отзывы: